DEVICE INFORMATION
Pressing MENU will take you to the selection menu for system settings. Using UP and DOWN, select the menu item "Sys Info" and confirm
with ENTER. You will then be taken to the sub-menu to display the device information. Use the UP and DOWN panels again to select the
desired sub-menu item and then press ENTER to retrieve the information (see table). Press MENU once more to return to the main display.
The main display is automatically activated if no input is made within about 30 seconds.
Sys Info
Temp
=
Temperature display of the LED unit
Temp LED
xxC / xxF
Temp C°/F°
°C (= display in degrees Celsius)
°F (= display in degrees Fahrenheit)
Op.Hours
=
Operating time display
Hour Total
Displays the total operating time in hours
Firmware
=
Displays the device software version
Vx. xx
Settings
Display
= Display lighting
Backlight ON
permanently on
Backlight Off
deactivation after approx. 30 seconds of
inactivity
DMX Fail
= Operation status with DMX signal interruption
Hold
last DMX command is held
Blackout
activates Blackout
DimCurve
= Dimmer Curve
Linear
The light intensity increases linearly with the
DMX value.
Exp
Adjustment of the light intensity is finer in the
lower DMX value range and coarser in the
upper DMX value range.
Log
The light intensity can be adjusted coarsely in
the lower DMX value range, and finely in the
upper DMX value range.
S Curve
The adjustment of the light intensity is finer
in the lower and upper DMX value ranges and
coarser in the middle DMX value range.
DimResp.
= Dimmer response
LED
The spotlight responds abruptly to changes in
the DMX value.
Halogen
The spotlight behaves in a manner similar to
that of a halogen lamp with gentle changes
in brightness.