2.5 Precautions for vacuum pump installation:
1. Take out the vacuum pump and pipeline assembly from
the accessories box, and connect one end of the pipeline
assembly to the air inlet of the vacuum pump (note that the
arrow indicates the air flow direction). Connect the silencer
to the exhaust hole of the vacuum pump. When using PTFE
tape for sealing, it is noted that three threads are left on the
front end of the joint thread, and not wrapped with PTFE
tape. Wrap the joint head from behind the three threads, to
avoid that PTFE tape is crushed and sucked into the vacuum
pump, causing the vacuum pump failure.
2. Connect one end of the attached silicone hose with the vacuum pump and the other end with the furnace to ensure that the
end of the silicone hose is sleeved to the root of the joint and ensure the air tightness.
3. Insert the power cord of the vacuum pump into the power output interface of the vacuum pump on the back plate of the
furnace, and turn on the main power switch. Pressing the power switch "1" indicates turning on the power, and pressing "0"
indicates turning off the power.
2.6 Active cooling fan
When the highest temperature insulation of the firing process is completed, automatically turn on the fan
to blow the external cold air to the furnace, help it quickly cool down, increase the cooling rate, and then
improve the efficiency of glazed porcelain.
2.7 Automatic temperature regulation
The system automatically adjusts the temperature after each roasting program is started.
This automatic temperature regulation system controls all possible deviations of relevant circuit
components, which ensures that the temperature deviation is controlled within±1
℃ under the condition
of long-time operation of the furnace.