Warning! For protection against dangerous electrical shocks, the device must be grounded (earthed). The local AC power
source must be supplied with both overload and ground-fault (earth fault) protection.
Important! Only attach or remove a Neutrik powerCON connector while it is connected to the mains to apply or cut power
in an emergency, as by doing so may cause arcing at the terminals that will damage the connectors.
POWER OUTLET
Warning! The total current load of all devices connected to the AC mains power outlet of the XNODE 4 must not exceed
19.8 amperes.
A power cable that meets the requirements specified in the safety instructions section of this manual must be used to connect the
XNODE 4 to AC mains power and to connect other devices to the power outlet.
A light-grey Neutrik powerCON NAC3FCB cable-mount connector must be used to draw AC mains power from the XNODE 4’s power
outlet.
No matter what the AC mains power voltage is, the current drawn by all the devices that draw AC mains power from the power outlet of
an XNODE 4 must not exceed a total of 19.8 amperes.
DMX CONNECTIONS
Depending on the version, the XNODE 4 is equipped with 5-pin or 3-pin XLR connectors or with Neutrik etherCON RJ45 connectors.
XLR CONNECTORS
Pin
Connection
1
Com
2
Data -
3
Data +
4
Not connected
5
Not connected
RJ45 CONNECTORS
Pin
Connection
1
Data +
2
Data -
3
Not connected
4
Not connected
5
Not connected
6
Not connected
7
Com
8
Com
Shield
Earth
Each output port is individually optically isolated.