    TECHNICAL MANUAL

 

  Air Cleaner CC400 Concealed

 

 

 

14.

 

Air Cleaner

 

Concealed

 

and

 

the

 

environment 

The

 

Air Cleaner

 

Concealed

 

air

 

purifier

 

is

 

made

 

from

 

lead-free

 

components.

 

It

 

can

 

be

 

recycled,

 

used

 

models

 

must

 

always

 

be

 

sent

 

to

 

a

 

recycling

 

station

 

for

 

correct

 

recycling

 

and/or

 

disposal

 

of

 

parts

 

and

 

components. 

 

 

 
 

14.1.

 

Air Cleaner

 

Concealed

 

filters

 

and

 

the

 

environment 

Note

 

that

 

filters

 

must

 

not

 

be

 

disposed

 

of

 

along

 

with

 

ordinary

 

household

 

waste.

 

Scrapped

 

filters

 

must

 

always

 

be

 

correctly

  

13

 

taken

 

care

 

of

 

and

 

handled

 

safely.

 

Recycling

 

or

 

disposal

 

must

 

always

 

be

 

carried

 

out

 

at

 

an

 

approved

 

waste

 

facility.

 

If

 

you

 

have

 

any

 

questions

 

about

 

this,

 

please

 

contact

 

your

 

local

 

authority

 

or

 

distributor

 

for

 

advice

 

on

 

correct

 

care. 

 

 

 

 
 

15.

 

Maintenance 

If

 

necessary,

 

the

 

Air Cleaner

 

Concealed

 

can

 

be

 

cleaned

 

using

 

a

 

mild

 

cleaning

 

agent. 

 

 

 
 

Before cleaning, always switch off the machine and pull out the electrical connector! 

 

 

16.

 

Instructions

 

for

 

replacing

 

Air Cleaner

 

Concealed

 

filters 

 

 
 

WARNING!

 

When

 

handling

 

used

 

filters,

 

personal

 

protective

 

equipment

 

such

 

as

 

protective

 

gloves

 

and

 

masks

 

must

 

be

 

used.

 

To

 

choose

 

the

 

correct

 

type

 

of

 

respiratory

 

protection,

 

consult

 

either

 

the

 

safety

 

representative/officer

 

at

 

the

 

workplace

 

or

 

the

 

manufacturer

 

of

 

the

 

respiratory

 

protection. 

 

Used

 

filters

 

may

 

contain

 

harmful

 

substances

 

and

 

particles.

 

With

 

incorrect

 

handling,

 

these

 

can

 

escape

 

to

 

the

 

environment

 

and

 

present

 

risks

 

of

 

sickness

 

and

 

ill

 

health. 

 

Filters

 

should

 

be

 

replaced

 

on

 

a

 

continuous

 

basis.

 

As

 

regards

 

frequency

 

of

 

filter

 

replacement,

 

see

 

Camfil

 

AB

’s

 

recommendations. 

Summary of Contents for CC400

Page 1: ...TECHNICAL MANUAL Air Cleaner CC400 Concealed Air Cleaner Consealed CC400 manual Ver 001 Oct 2018 1 ...

Page 2: ...ESIGN 8 10 1 CONSTITUENT STANDARD COMPONENTS 8 11 TRANSPORT AND UNPACKAGING 8 10 2 AIR FLOW DETAILS 9 12 TAKING INTO OPERATION 10 12 1 POSITIONING 10 12 2 SYSTEM INTEGRATION 10 12 3 4 5 6 ELECTRICAL CONNECTION 11 13 MEASSURING POINT FOR PA 12 14 AIR CLEANER AND THE ENVIRONMENT 13 14 1 AIR CLEANER FILTERS AND THE ENVIRONMENT 13 15 MAINTENANCE 13 16 INSTRUCTIONS FOR REPLACING AIR CLEANER FILTERS 13 ...

Page 3: ...first few sections also give some technical specifications After these there are illustrated texts about the various parts that make up the Air Cleaner Concealed The user manual also includes details of safety procedures associated with the use of the machine 3 Version history Version Date Signature Altered 001 See approval Initial version 4 Identification plate All Air Cleaner Concealed type mach...

Page 4: ...mportant 4 Before using your Air Cleaner Concealed air it is important that you as the user read this user manual read the fan instructions and follow the safety instructions in both documents 7 Technical specifications External dimensions vertical model Height 313 mm Width 1112 mm Depth 327 mm Weight 21 9 kg including new filters Filter weight 6 5 kg 1 pcs XLT and 1 pcs x Hepa 13 7 1 Fan specific...

Page 5: ...ng mounting If the Air Cleaner Concealed is to be mounted in a ceiling or on a wall the following points must be borne in mind 1 Ceiling mounting the unit must be so mounted that there is no risk of trucks and similar colliding with it 2 The ceiling or wall must be able to take a load of 88 kg 3 Always install with safety switch to disconnect the power supply during services or maintenance 4 Only ...

Page 6: ...TECHNICAL MANUAL Air Cleaner CC400 Concealed Air Cleaner Consealed CC400 manual Ver 001 Oct 2018 8 2 Mounting drawings 6 ...

Page 7: ...ection may only be carried out by an appropriately qualified electrician Wall outlets must also be installed by an appropriately qualified electrician 5 Accessories filters spare parts etc used with the Air Cleaner Concealed must be approved by Camfil AB Guarantee undertakings cease to apply if the foregoing is not respected Please contact Camfil AB for the correct accessories 6 Do not cover inlet...

Page 8: ...tandard version the air purifier is supplied with the following components One Air Cleaner Concealed unit with 2pcs of circular take off Ø 250 mm These have rubber gaskets and can be connected to Spiro type circular ducts One protective Lock for filter replacement Filters for the chosen purpose User manual Fan instructions from the fan supplier If anything is missing or if you require further info...

Page 9: ...here is the HEPA filter This is a unique environment friendly absolute filter It is so efficient that air must pass three times through the ventilation system to achieve the same level of air purification as it does in a single circulation through the Air Cleaner The extremely large filter surface increases both service life and filter efficiency Further increases of the HEPA EPA filter s service ...

Page 10: ...e 50 cm around outlet and inlet 12 2 System integration When connecting ventilation ducts to the Air Cleaner Concealed these items must be secured to support their own weight There is not recommended to connect more than 8 meters of 250mm circular ventilation ducts on outlet and inlet of the unit 12 3 Electrical connection Electrical connection must be carried out by an appropriately qualified ele...

Page 11: ...8 TECHNICAL MANUAL Air Cleaner CC400 Concealed 12 4 Electrical Connection 1 phase EC fan NB Only appropriately qualified electricians may carry out work on or in this machine 11 Electrical connection with Controller Card fuse holder and RS485 connector ...

Page 12: ...TECHNICAL MANUAL Air Cleaner CC400 Concealed 13 Measuring points for Pa or filter efficiency tests Filter efficiency Pressure drop A Before filter A B Pre filter B After Pre filter B C HEPA filter C After HEPA filter A C Pressure both filters 12 A B A C ...

Page 13: ...lease contact your local authority or distributor for advice on correct care 15 Maintenance If necessary the Air Cleaner Concealed can be cleaned using a mild cleaning agent Before cleaning always switch offthemachine andpull outtheelectricalconnector 16 Instructions for replacing Air Cleaner Concealed filters WARNING When handling used filters personal protective equipment such as protective glov...

Page 14: ...move it NB Hold the top cover firmly Alternatively secure it during removal 3 Grip the upper edge of the bag filter frame pull it towards you And put the filter into a plastic bag 4 Release the screw counter clock wise which keeps the HEPA filter in place 5 Take a firm grip the sling which is around the HEPA filter and pull it towards you 14 6 Lift the filter carefully out Scrapped filters must be...

Page 15: ...hine must not be placed in extremely high or low temperatures The guarantee does not cover problems arising through carelessness negligence Remember that the classification covers the machine only and not the filters For information about filters contact your local Camfil office 18 EU provisions governing the product This product complies with EU standards as per the machine directive 2006 42 EC t...

Page 16: ...enters the compartment By doing this a thoroughly controlled indoor environment is achieved in the space in question This is useful in processes such as those involving installation food electronic installation and other sensitive production units Under pressure In this example the air is sucked from the compartment and purified before it is discharged into the room Air Cleaner also makes it possi...

Page 17: ...d with each other With the aid of a calibrated particle counter the quantity of particles in the air can be examined By subscribing to this service you will as a customer always have a particle counter in place connected to a computer which monitors the indoor environment When an abnormal particle distribution is identified or in cases of other suspected problems we perform an analysis with a scan...

Page 18: ...wer stations Camfil Farr is a global company with 29 subsidiaries 23 production plants and an extensive network of agents in Europe the Americas and the Asia Pacific region Air Cleaners Air Cleaners is synonymous with high efficiency purification energy savings and almost silent operation Unlike all other air purifiers on the market our HEPA filters offer a degree of purification that can eliminat...

Reviews: