EMC_SPEC040_CLCR.doc
Rev. E
–
2021 10 18
42/63
Install & Operating Manual
CleanSeal V3
Clamping Height Base Settings
PLEASE NOTE :
Clamping height and / or compression can be further adjusted :
•
Lift the clamping lever to its vertical position,
then
•
Turn clockwise for more compression
•
Turn counter-clockwise for less compression
1 turn 360° = +/- 0,8 mm compression
Adjust in half turns, so the closed clamping lever remains always parallel to the housing wall.
Height setting
nominal
+
-
clamp closed
add compression less compression
min
max
h
PU
[mm]
[turns] / [mm]
[turns] / [mm]
[mm]
[mm]
MD
67,5
+0,5 / 0,5
-13 / -10,5
67
78
78
79,5
+0,5 / 0,5
-13 / -10,5
79
90
MX
91,5
+0,5 / 0,5
-13 / -10,5
91
102
MG
111,5
+0,5 / 0,5
-13 / -10,5
111
122
Height setting
nominal
+
-
clamp closed
add compression less compression
min
max
h
PU
[mm]
[turns] / [mm]
[turns] / [mm]
[mm]
[mm]
MD
71
+5 / 4
-9 / -7
67
78
MX
105
+2,5 / 2
-11 / -9
103
114
MG
115
+5 / 4
-9 / -7
111
122
Range Adjustment
PU
Filter
Type
GEL
Filter
Type
Range Adjustment
Clamping Height
Range
Clamping Height
Range