EMC_SPEC040_CLCR.doc
Rev. E
–
2021 10 18
15/63
Install & Operating Manual
CleanSeal V3
8
Installation of Housings
8.1
Unboxing & Handling
•
Open the TOP of the box (see pictogram on the side of the box)
•
Retrieve the bag(s) of accessories and remove protective foam parts
•
Damper ready S-C-versions will contain a second pouch with the damper adapter rod.
•
Extract housing from the box using the duct hole as a grip.
DO NOT lift the housing by the dp-port tube.
•
We recommend keeping spigot and flange protection in place to prevent handling damage.
Detach and dispose of at the last possible opportunity:
•
Install the housing directly or place flat on a
protected
surface to avoid scratching
Check filter height clamp settings at this point and adjust, if necessary (
see also § 10.2
).
PLEASE NOTE:
The ceiling / wall flange is the most fragile part of the housing.
Accidental bending will result in paint cracks which, in turn, will compromise
corrosion protection.
Avoid shocks and supporting the housing weight by the flange or flange corners:
NO
YES
NO