NOTE: The centre line of your return panel should ideally fall anywhere from the centre of the threshold to no less than 0.5”
from the edge of the base.
The opening on a 48“ unit (from finished wall to return panel) is 45.00” to 47.50“.
The opening on a 60“ unit (from finished wall to return panel) is 56.75” to 59.25“.
To locate the centre line of your return panel, place the second wall jamb up against the end of the rail and adjust until
plumb using a level as shown. If the centre line of the wall jamb does not fall in this area, you may be required to lengthen
the rail by using the wall mount extension (26).
Once you are satisfied with the location, mark the centre line of the wall jamb onto the base, and carry the line to the wall
on the return panel side. Ensure that this line stays parallel to the edge of the base.
12.
Mark return panel position
15
A
B
A
B
A
B
www.camltomlin.com
FLOW INSTALLATION - CORNER
A
26