Installation  and  Maintenance  Rules  for:

STANDARD  FEATURES

INSTALLATION

Fig.1

Fig.2

Bladed  level  gauges  PFG-86

00625  97.06  -  Rev. 05

The  

PFG-86

  level  gauge  is  made  in  compliance  with  the  regulations  in  force  in  the  European  Union  and  specifically  with:

- Die-cast  aluminium  casing  UNI 5076.  IP65  protection.
- Stainless  steel  shaft  on  ball  bearings,  watertight  with  permanent  lubrication,  with neoprene  Corteco  ring  for  dust  sealing.
- Standard   Nylon   screw,   on   request   made   of   stainless   steel   or   other   materials   and   versions   with   1,  2,  3  or  4   blades.
- Electrical construction in compliance with Directives 2014/35/EU (low-voltage electrical material) and 2014/30/EU (electromagnetic

compatibility).

- Output speed (screw shaft):  1rpm.

SAFETY  RULES

All  the  appropriate  safety  precautions  must  be  taken  when  electrically  operated  equipment  is  used,  in  order  to  reduce
the  risk  of  fire  outbreaks,  electric  shock  and  injuries  to  persons.

- Keep  the  work  zone  clean  and  orderly.  Accidents  are  more  likely  to  occour  in  untidy  areas  and  environments.
- Before  beginning  work,  make  sure  that  the  level  gauge  is  in  a  perfect  condition.  Damaged  or  broken  parts  must  be

repaired  or  replaced  by  competent  personnel  authorized  by  the  Manufacturer.

- All   verifications,   inspections,   cleaning   and   maintenance   operations,   part   changes   and   replacements   must   be   carried

out  with  the  level  gauge  disconnected  and  the  plug  removed  from  the  power  socket.

- It  is  absolutely  forbidden  for  children,  unauthorized  and/or  inexpert  persons  to  touch  or  use  the  level  gauge.
- Make   sure   that   the   electricity   system   complies   with   the   laws   in   force.   Make   sure   that   the   earthing   is   efficiently

connected   when   the   instrument   is   installed.   Check   to   be   sure   that   the   power   socket   is   suitable,   that   it   complies

- The   level   gauge   must   never   be   stopped   by   detaching   the   plug   from   the   power   socket.   Moreover,   never   use   the

cable  to  pull  the  plug  from  the  socket.

- Periodically   check   to   be   sure   that   the   cable   is   in   a   perfect   condition   and   replace   it   if   damage   is   discovered.

This   operation   must   only   be   carried   out   by   competent   and   authorized   persons.   Only   use   extensions   cables   of   the

- Protect  the  cable  against  high  temperatures,  lubricants  and  sharp  edges.  Do  not  twist  or  knot  the  cable.
- Do  not  allow  children  or  unauthorized  persons  to  touch  the  cable  when  the  instrument  is  plugged  in.

Before   installation,   inspect   the   outer   structure   of   the   level   gauge.   Check   the   movement   of   the   screw   shaft   and
the   operation   of   the   clutch   assembly.   If   this   check   reveals   anything   irregular,   the   level   gauge   must   be   sent   to

CAMLogic

  to  be  restored  to  efficiency.  

CAMLogic

  level  gauges  can  be  installed  in  any  position.  With  the  shaft  in  a

M

REGGIO  EMILIA   ( Italy )

BREVETTO

N.  656961

PFG 86

Tipo

N.

10A.250V.c.a.

110

220

0

VUOTO

PIENO

7

6

5

4

1

2

3

horizontal  or  sloping  position,  the  level  gauge  must
be  mounted  with  the  wiring  plate  inside  the  casing
in  an  upright  position  and  the  cable  passages  on
the  right-hand  side  ( Fig.1 ).
The  level  gauge  is  mounted  on  the  chambers  or
silos,  on  the  side  or  top.
It   is   important   to   choose   the   position   so   that
the   device   is   not   hit   by   the   falling   load,   likewise
taking   care   that   the   material   can   move   freely   all

weighing  on  the  shaft  or  when  material  that  flows
badly  is  likely  to  move  in  a  block.

with  the  laws  in  force  and  that  it  has  a  build  in  automatic  protection  circuit-breaker.

permitted  type  and  marked.

The   level   gauge   can   be   mounted   on   the   silos   by   the   standard   connection   with   threaded   sleeve   (  2"  1/2   Gas  )   to   be
welded   onto   the   silos   (  PFG-86  )   or   by   flange   connection   with   6MA   screws   (  PFG-86/F  ).   These   two   methods   involve

around   the   gauge.   Protective   deflectors   (  Fig.2  )
are   advisable   when   there   is   considerable   weight

no   modifications   to   the   level   gauge   since   the   flange   uses   the   thread   on   the   body   of   the   gauge   envisaged   for   the
sleeve.   When   mounting   with   the   sleeve,   the   gauge   must   be   fully   screwed   onto   the   sleeve,   then   it   is   necessary   to
turn   it   to   obtain   an   upright   position   of   the   wiring   plate,   then   tighten   the   securing   screw   on   the   threaded   sleeve.

R

S.a.s. di Guazzetti Giovanni & C.

COSTRUZIONI  MECCANICHE  ELETTRICHE

Via  dell' Industria  12 - 12/A  -  42025  CAVRIAGO  -  RE  -  Italy
Tel. 0522942641 - 0522941172 - Fax  0522942643

www.camlogic.it

e-mail  camlogic@camlogic.it

0948

ATEX  MARKING:   II 1/2 D Ex ta/tb IIIC T85°C Da/Db

Group II, intended for use in surface industry.

Suitable for Cat. 1 - Zone 20 inside silos (shaft with screw); Cat. 2 – Zone 21 external (indicator casing).

Temperature class - maximum superficial temperature of the device 85°C.

Equipment Protection Level for dust atmospheres. Da (very high) for zone 20 (internal); Db (high) for zone 21 (external).

Protection method Ex t - protected against dust (ta internal / tb external).
Dust group C (suitable for operation in presence of all types of dust, conductives included).

II
1/2 D
Ex ta/tb
IIIC
T85°C
Da/Db

- Noise level measured in open field:  zero.
- Motor absorption:  4 Watts.

- Use contact capacity: 10 A. at 250 VAC.

- Envisaged power supplies:  110/220 VAC or 24/48 VAC  50/60 Hz  -  24 VDC.