9
be stopped, do not try to repair. Call for
replacement parts. Order new parts by
giving the serial number, model number
and name of items needed to the Service
Center at 1.800.650.2433.
6. Always close LP tank valve after performing
tank leak test by turning hand wheel
clockwise.
WARNING
• Do not use appliance until leak checked.
• If you cannot stop a gas leak, immediately
close LP tank valve and call LP gas
supplier or your fire department!
Hose Check
• Before each use, check to see if hoses
are cut or worn. Replace damaged hose
assembly before using appliance. Use
only valve/hose/regulator specified by
manufacturer. See product sheet for hose &
regulator information.
Valve Check
Visually inspect the valve to burner assembly
to ensure the orifice is properly located in the
burner. As shown.
Low FLow Mode
This regulator is equipped with a Low-Flow
detection device for your safety.
Troubleshooting
To prevent your regulator and tank from going
into Low-Flow Safety Mode, follow these
simple guidelines:
1. TIGHTEN. Ensure that all control knobs on
the stove and tank are turned OFF. Use a
wrench to connect hose to stove. Connect
regulator to tank. Securely tighten.
2. SLOWLY OPEN. Twist open the knob on
your propane tank slowly. When opened
too quickly, the regulator will enter into
Safety Mode, which greatly reduces heat
output and gas flow to your stove.
Lighting Instructions
Follow the instructions exactly.
1. Check that the burner control knob and
the cylinder valve are turned to the “OFF”
position.
2. Turn on the fuel supply by rotating the
cylinder valve knob counter-clockwise to full
open.
3. DO NOT stand with head, body, or arms
over the grill when lighting.
Lighting The Main Burner
1. Make sure the control knob is in the “OFF”
position.
2. Push and turn the control knob to the
“HIGH” position.
3. If ignition does NOT occur in 5 seconds,
turn control knob to “OFF”, wait 5 minutes
to allow gas to dissipate and repeat lighting
procedure. If burner does not ignite, wait
5 minutes, see “Match Lighting the Main
Burners” section.
4. To turn off, turn the control knob clockwise
until it locks in the “OFF” position. This
does not turn off the gas flow from the
cylinder.
Note: If burner does not light or flame is too
low, you may have spider or other insect
blockage in burner. See “Burner Assembly/
Maintenance” under Proper Care and
Maintenance. Also refer to Low Flow section.
Match Lighting The Main Burners
1. Turn the burner control knob to “OFF”.