background image

“PRERR” - The digital readout will display “PRERR” when the 
Probe Temp button is pressed if either the external probe is not 
plugged in or there is a problem  
with the probe.
“FEED” - The digital readout will display “FEED” if dial is turned 
to the feed mode. After 7 minutes the auger will turn off.  
“BPASS” - The digital readout will display “BPASS” when the 
bypass button is pressed and held in for 3 seconds. See the 
setting on Bypass Mode.
“FLAME” - The digital readout will display “FLAME” if the fire is 
extinguished.

BREAKING IN THE GRILL

We suggest turning the grill to 350F for ½ hour before cooking on 
the grill for the first time. This will burn off any manufacturing 
oils and cure the paint. Make sure to follow the instructions for 
filling the auger tube before breaking in the grill.

COOKING

Once the auger tube has been properly filled you can begin 
cooking by selecting any of the cooking temperatures. The grill 
has 13 cook settings. Low Smoke, High Smoke, 175, 200, 225, 
250, 275, 300, 325, 350, 375, 400, and High. By selecting any of 
these the grill will go into the Startup mode. The digital readout 
will display “START” for 8 minutes during the startup cycle. 
After the 8 minutes the digital readout will display the internal 
temperature of the grill. The dial can be changed at any time 
during the startup cycle or the cook cycle between any of the 13 
cook settings. 

SHUTDOWN

 

When you are done cooking the dial must be turned to the 
Shutdown setting. The digital readout will display “SDOWN”. In 
this setting the fan will remain on for 10 minutes to finish burning 
any pellets in the burner and cool the grill down. After 10 minutes 
the digital readout and auger will turn off. At this point the main 
power switch should be switched to off. Before grill can be used, 
the power switch must be turned off and back on.

BYPASS MODE

The bypass may be used if there is a power failure, or the grill is 
accidentally turned off, or anytime you need to restart the grill 
and it is still hot. The bypass mode should only be used if the 
grill has been off less than 3-4 minutes. This method is used to 
bypass the normal startup mode and get the grill cooking again 
quickly. The burner must still be hot enough to ignite new pellets 
or this method will not work. In order to initiate the bypass mode 
you must first select the cook setting you want. At this point 
the digital readout will display “START”. Simply press the green 
bypass button in and hold it for 3 seconds. The digital readout 
will display “BPASS”. Release the green button and the grill will 
go into the cook mode and the digital readout will display the grill 
temperature. If the grill fails to ignite using the bypass mode then 
restart the grill using the normal startup procedures.

MEAT PROBE

 

This grill has a built in meat probe to measure the temperature 
of the food as it is being cooked. To use this probe insert the 
wire through the stainless flap on the side of the firebox. Insert 
the probe into the food. Plug the connector into the receptacle 
on the front of the control panel. When you press the green probe 
temp button on the front of the controller the digital readout will 
display the food temperature. Press the button a second time to 
toggle the display back to the cooking temperature. If the probe 
is not installed correctly or there is an error with the probe the 
digital readout will display “PRERR” when the probe temp button 
is pressed. When running the probe wire to the food make sure it 
is positioned out of direct contact with any open flame or damage 
may occur. The digital readout will display a “P” in front of the 
number when displaying the meat probe temperature. 

Example: “P155F”

CLEANING

Clean grates using a wire grill brush. This should be done with 
each use. DO NOT use oven cleaner or abrasive cleaners on the 
painted grill surfaces. Use warm soapy water on all painted 
surfaces. Clean grease pan, grease trough, and grease drain tube 
occasionally. A spatula can be used to scrape excess grease and 
a grill brush to brush clean. Do not allow grease to build up on the 
grease tray or in the grease trough as this can cause flare-ups 
inside the grill. The grease tray can also be lined with aluminum 
foil for easier cleanup. Make sure not to obstruct the flow of 
grease off of the tray and into the grease trough. Make sure not to 
block the airflow to the temperature sensor on the left side of
the grill.

FILLING THE AUGER TUBE

CAUTION: ONLY USE THE FEED SETTING WHEN HOPPER HAS RAN 

OUT OF PELLETS. FEED SETTING IS NOT FOR NORMAL USE.

The first time you use your grill or any time the hopper has ran out 
of pellets you will need to fill the auger tube. This simply means 
you must fill the auger tube with pellets until pellets reach the 
burner. This is done by turning the dial to the FEED position and 
then holding in the bypass button for 3 seconds. This will turn the 
auger on and the digital readout will display “FEED”. The auger 
will remain on for no more than 7 minutes. This is ample time for 
the pellets to reach the burner. It is easiest to open the burner 
clean-out by pulling the knob on the right side of the grill. Once 
you hear pellets dropping into the cup you can close the
clean-out port by pushing the knob on the right side of the grill 
and then select your cooking temperature. (Never operate grill 
without the ash cup in place). Always make sure the burner 
clean-out port is closed by pushing in the knob on the right side of 
the grill before selecting any of the cook settings. Never open the 
burner clean-out port when the grill is hot.

EMPTYING THE HOPPER

This grill is equipped with a hopper drain to quickly remove the 
pellets from the hopper. This can be used to remove pellets if the 
grill is being stored for a long time or to remove pellets to change 
to a different flavor pellet.

Warning:

 Never remove the auger guard from the hopper while the 

pellet grill is on. Never operate the grill without the auger guard
in place.

Caution:

 The instructions below must be followed when emptying 

the hopper.
1. Unplug the grill from the power source.
2. Hang a bucket or use a box to catch the pellets that will come 
    out of the tube on the rear of the hopper.
3. Lift the pullout lock on the left side of the hopper and pull the 
    hopper cleanout knob.
4. Sweep the remaining pellets in the hopper towards the drain 
    hole using the included rake to reach through the guard.
5. Push in the hopper cleanout knob and lock in place using the 
    pullout lock.
6. Store the rake in the corner of the hopper as shown in Fig.12.

CONTROLLER EXPLANATION

POWER SWITCH 

Used to turn the main power onto the pellet grill. If the dial is on 
Shutdown when the power switch is turned on the digital readout 
will display “-----“. The dial must be rotated to any of the other 
positions before the grill will start. If the power is turned on 
with the dial in any other position than Shutdown the grill will 
immediately start that function. “O” is Off. “-“ is On. See Fig. 13

DIAL POSITIONS 

SHUTDOWN 

This setting must be used after each use. Turn the dial to this 
setting and the fan will remain on for 10 minutes before turning 
off. This setting will burn up any extra pellets in the burner and 
cool down the grill. Do not turn the main power switch off when 
the grill is hot.

FEED

 - This setting is used to feed pellets to the burner. It will 

be used the first time you use the grill to fill the auger tube and 
any time you may inadvertently run the hopper out of pellets. See 
instructions on filling the auger tube.

LOW SMOKE

 - This setting is used for smoking foods at an 

average temperature of 160F. This setting will produce large 
amounts
of smoke.

HIGH SMOKE 

- This setting is used for smoking foods at an 

average temperature of 220F. This setting will produce large 
amounts of smoke.

175F TO 400F - There are 25F increment settings from 175F
to 400F. You can simply select any temperature you want 
and the grill will control the temperature within 15F of the 
selected temperature.

HIGH

 - This setting can be used to achieve temperatures up to 

500F depending on ambient temperatures.

DISPLAY

 

“START” - The digital readout will display “START” each time the 
dial is changed from the OFF, SHUTDOWN, or FEED settings to any 
of the cook settings. The startup cycle is approximately 8 minutes. 
During the cook cycle after the start sequence the digital readout 
will display the temperature inside of the grill. If the Probe Temp 
button has been pressed then it will display the temperature of 
the external probe used for measuring meat temperatures.
“SDOWN” - The digital readout will display “SDOWN” when the 
dial is turned to the shutdown mode. After 10 minutes the digital 
readout and the fan will turn off.
“SENSR” - The digital readout will display “SENSR” if there is an 
error with the temperature sensor inside of the grill.

Fig. 12

 WARNING

Always start the grill with the lid open. 

The lid must be closed after the 

start cycle.

RAKE

HOPPER CLEANOUT

Fig. 13

 WARNING

Do not over-fire the grill by over feeding 

pellets into the burner prior to startup. 

If flame is inadvertently extinguished 

never restart the grill without first 

cleaning out the burner. Improper use 

can cause an uncontrolled fire. 

Summary of Contents for SMOKEPRO PG24-3

Page 1: ...PELLET GRILL AND SMOKER WARNING INSTRUCTION BOOKLET MODEL NUMBER PG24DLX 3 PG24 3 PG24S 3 5003132 Conforms to UL SUBJECT 2728 Certified to CSA STD C22 2 3...

Page 2: ...nia to cause cancer Avoid inhaling dust generated from wood products or use a dust mask or other safeguards to avoid inhaling dust generated from wood products Wood products emit chemicals known to th...

Page 3: ...appliance as a heater 5 Do not operate appliance under ANY overhead construction Keep a minimum clearance of 10 feet 3 m from the sides front and back of appliance to ANY construction Keep the area cl...

Page 4: ...Probe BURNER CLEAN OUT Before each use the burner should be cleaned out by lifting the pullout lock and pulling the clean out port knob on the right side of the grill to open the burner clean out Thi...

Page 5: ...PELLETS FEED SETTING IS NOT FOR NORMAL USE The first time you use your grill or any time the hopper has ran out of pellets you will need to fill the auger tube This simply means you must fill the auge...

Page 6: ...nd the auger is not you will need to replace the auger pin If problem cannot be resolved please call customer service DIGITAL READOUT DISPLAYS SENSR 1 Turn the power off and unplug the grill 2 Check t...

Page 7: ...thick fat caps down to a quarter inch Rinse and pat dry to prepare to apply the dry rub Coat the butt liberally with dry rub being sure to cover all sides and spaces This can be done up to one day bef...

Page 8: ...4DLX 3 PG24 3 PG24S 3 www CampChef com 1 800 650 2433 Camp Chef is a registered trademark of Logan Outdoor Products 2016 Patent Pending 3985 N 75 W Hyde Park UT 84318 USA Made in China 0216_PG24_Instr...

Page 9: ...d alimentation Ensemble du r servoir granules Pied gauche Bouchon du pied Rondelle plate M10 2 crou borgne M10 2 R cipient cendres Roulette Axe de roulette Pied droit Boulon M8 x 55 8 Seau de collecte...

Page 10: ...liser en toute s curit 4 Destin un usage EN PLEIN AIR uniquement NE PAS utiliser l int rieur d un immeuble d un garage ou de tout autre endroit ferm NE PAS utiliser dans un v hicule r cr atif ou sur u...

Page 11: ...le syst me de blocage de la tige est tir vers le bas et bloque le bouton afin d emp cher l ouverture de la zone de nettoyage par inadvertance Voir la Fig 9 2 Soulever le syst me de blocage de la tige...

Page 12: ...e fum e HIGH SMOKE Ce r glage est utilis pour fumer des aliments une temp rature moyenne de 104 C 220 F Il produit beaucoup de fum e 175F TO 400F Ce r glage permet d augmenter la temp rature par tranc...

Page 13: ...UMER Le barbecue refuse de s allumer apr s avoir positionn l interrupteur sur la position Marche 1 S assurer que le barbecue est branch sur une prise secteur aliment e V rifier le disjoncteur et ou di...

Page 14: ...ommande Sonde RTD Cordon d alimentation Blanc Rouge Blanc Orange Blanc Mauve Tige d allumage Connecteur MOLEX Fusible Allumage en mode bypass Sonde Alimentation Attention Utiliser uniquement le param...

Reviews: