21 - 64
FAULTS
Temporary tool stopping during the use
(the LED flashes – picture E).
The tool is not powerful enough.
The LED 1 (5) of the battery -charger (3)
does not switch on.
The LED 2 (6) of the battery charger (3)
does not switch on.
Any other fault.
The tool stops while working (the Power
12 LED is OFF – picture E).
CAUSE
• Flat battery (2).
• Flat battery (2).
• Battery-charger failure.
• Battery-charger failure.
• Wrong device working.
•
Safety block of the battery electronic
card.
REMEDY
• Re-charge the battery.
• Re-charge the battery.
• Take the device to an authorized
service point.
• Take the device to an authorized
service point.
• Take the device to an authorized
service point.
• Recharge the battery
LED 1 (power) LED 2 (charger)
Meaning
1
OFF
OFF
• power supply cable not plugged in
2
ON
OFF
• battery non connected
3
ON
ON
• green LED 2: battery is charged up
4
ON
FLASHING
• green light: battery under charge – red light: battery out of order
5.4 Use of the battery-charger
•
The battery-charger (3) control is made by means of 2 LED lights: LED1 (5) and LED2 (6). The ENERGY 6 version is fitted
with just one LED light, which is green when the battery is charged up and flashing green when the battery is under
charge, while it is red when the battery is out of order. The battery (2) recharge follows the time sequence from 1 to 4.
•
When connecting a brand new or a flat battery (2), the battery-charger (3) begins a pre-formatting phase at low current.
The LED (5) is on, the LED (6) flashes.Only after the battery (2) has reached the correct voltage level, the recharging
phase begins.
•
The battery (2) recharging time depends on the cells capacity and the residual charge. The maximum recharging time is
10 hours.
5 - USE OF THE TOOL
5.5 Troubleshooting