CHN10302, CHN10310

www.chpower.com

Important Safety Instructions 

(Continued) 

AIR SOURCE

a.   Never connect to an air source that 

is capable of exceeding 200 psi. 
Over pressurizing the tool is able 
to result in bursting, abnormal 
operation, breakage of the tool or 
serious injury to persons. Use only 
clean, dry, regulated compressed air 
at the rated pressure or within the 
rated pressure range as marked on 
the tool. Always verify prior to using 
the tool that the air source has been 
adjusted to the rated air pressure or 
within the rated air-pressure range. 

b.   Never use oxygen, carbon dioxide, 

combustible gases or any bottled 
gas as an air source for the tool. 
Such gases are capable of explosion 
and serious injury to persons. 

 

Do not  

  use any 

type of reactive gases, 
including, but not limited 
to, oxygen and combustible 
gases, as a power source. Use filtered, 
lubricated, regulated compressed air 
only. Use of a reactive gas instead of 
compressed air may cause the tool 
to explode which will cause death or 
serious personal injury.
 

Use  

  only a 

pressure-regulated 
compressed air source to limit 
the air pressure supplied to 
the tool. The regulated pressure must 
not exceed 100 psi. If the regulator 
fails, the pressure delivered to the 
tool must not exceed 200 psi. The tool 
could explode which will cause death or 
serious personal injury.

SAvE THESE INSTRUCTIONS 

DO NOT DISCARD

Operating Instructions

LUbRICATION

This tool requires lubrication before 
using the tool for the first time and 
before each use. If an inline oiler is 
used, manual lubrication through the 
air inlet 

is not

 required on a daily basis.

 

The work surface  

  can become 

damaged by excessive lubrication. 
Proper lubrication is the owner’s 
responsibility. Failure to lubricate the 
tool properly will dramatically shorten 
the life of the tool and void your 
warranty.

1.   Disconnect the air 

supply from the tool 
to add lubricant. 

2.   Turn the tool so the 

air inlet is facing up. Place 
4-5 drops of 30 W non-
detergent oil into air inlet. 
Do not use detergent 
oils, oil additives, or air- tool oils. 
Air tool oils contain solvents which 
will damage the tool's internal 
components. 

3.   After adding oil, run 

tool briefly. Wipe off 
any excess oil from 
the cap exhaust.

RECOMMENDED HOOKUP

The illustration below shows the 
recommended hookup for the tool.
1.   The air compressor 

must be able to 
maintain a minimum 
of 60 psi when the 
tool is being used. An inadequate air 
supply can cause a loss of power and 
inconsistent driving.

2.   An oiler can be 

used to provide oil 
circulation through 
the tool. A filter can 
be used to remove liquid and solid 
impurities which can rust or “gum 
up” internal parts of the tool. 

3.   Always use air supply hoses with 

a minimum working pressure 
rating equal to or greater than the 
pressure from the power source if a 
regulator fails, or 150 psi, whichever 
is greater. Use 1/4 inch air hose for 
runs up to 50 feet. Use 3/8 inch or 
greater air hoses for 50 foot run 
or longer. For better performance, 
install a 3/8 inch quick plug (1/4 inch 
NPT threads) with an inside diameter 
of .315 inch (8mm) on the tool and 
a 3/8 inch quick coupler on the air 
hose.

4.   Use a pressure regulator on the 

compressor, with an operating 
pressure of 0 - 125 psi. A pressure 
regulator is required to control 
the operating pressure of the tool 
between 60 and 100 psi. 

OIL

O

CO

2

100 psi

150 psi or greater

60 psi 

Min.
100 psi 

Max.

Recommended Hookup

Quick Plug

Air Hose

Quick Plug (Optional)

Regulator

Filter

Quick 

Coupler

Lubricator

Quick 

Coupler 

(Optional)

Summary of Contents for CHN10310

Page 1: ...xhaust single sequential trigger quick clear nose and an adjustable depth of drive mechanism Unpacking After unpacking the unit inspect carefully for any damage that may have occurred during transit M...

Page 2: ...top of another nail This is able to cause the nail to be deflected and hit someone or cause the tool to react and result in a risk of injury to persons k Remove finger from the trigger when not drivin...

Page 3: ...or unloading the tool Such precautionary measures reduce the risk of injury to persons e Store the tool when it is idle out of reach of children and other untrained persons A tool is dangerous in the...

Page 4: ...amaged by excessive lubrication Proper lubrication is the owner s responsibility Failure to lubricate the tool properly will dramatically shorten the life of the tool and void your warranty 1 Disconne...

Page 5: ...e tool must not operate Do not use the tool if it operates while lifted from the work surface Personal injury may result 7 Pull the trigger and depress the WCE against the work surface The tool MUST N...

Page 6: ...and they should use genuine Campbell Hausfeld replacement parts and accessories or parts and accessories which perform equivalently Assembly Procedure For Seals When repairing a tool the internal par...

Page 7: ...ece 2 Clean drive channel 3 Dirt or damage prevent fasteners or pusher from moving freely in magazine 3 Clean magazine 4 Damaged pusher spring 4 Replace spring 5 Inadequate air flow to tool 5 Check fi...

Page 8: ...instructions provided in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or...

Page 9: ...apide r glage de p n tration des attaches D ballage D s que l appareil est d ball l inspecter attentivement pour tout signe de dommages en transit S assurer de resserrer tous les raccords boulons etc...

Page 10: ...des blessures k Retirer le doigt de la g chette lorsqu on n enfonce pas d attaches Ne jamais transporter l outil avec le doigt sur la g chette car l outil pourrait d clencher l attache Toujours bien s...

Page 11: ...util lorsqu il n est pas utilis hors de port e des enfants et autres personnes non form es Un outil est dangereux dans les mains d utilisateurs non form s f Il faut entretenir l outil avec soin Gardez...

Page 12: ...n canalisation le graissage manuel travers la prise d air n est pas exig quotidiennement La surface de travail peut tre endommag e par le graissage excessif Le graissage correct est la responsabilit d...

Page 13: ...Il y a risque de blessures 7 Actionner la g chette Appuyer le m canisme de d clenchement par contact WCE sur la surface de travail La cloueuse NE DOIT PAS FONCTIONNER 8 Appuyer le m canisme de d clenc...

Page 14: ...L OUTIL Seul le personnel d ment qualifi devrait r parer l outil en utilisant des pi ces de rechange et des accessoires Campbell Hausfeld authentiques ou des pi ces et accessoires qui fonctionnent de...

Page 15: ...rainure du chassoir 3 Salet ou dommage qui emp che le fonctionnement libre des clous ou du poussoir dans le chargeur 3 Nettoyer le chargeur 4 Ressort de poussoir endommag 4 Remplacer le ressort 5 Cir...

Page 16: ...sation abusive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ce...

Page 17: ...a de despeje r pido y mecanismo clavador con profundidad ajustable Desempaque Al desempacar este producto rev selo con cuidado para cerciorarse de que est en perfecto estado Cerici rese de apretar tod...

Page 18: ...asuma que la herramienta contiene clavos No apunte con la herramienta hacia usted o hacia otra persona ya sea que contenga clavos o no j No clave ning n clavo encima de otro clavo Esto puede hacer que...

Page 19: ...esultar en muerte o graves lesiones personales No toque el gatillo a menos que se est n clavando sujetadores Nunca conecte la l nea de aire a la herramienta ni mueva la herramienta cuando est tocando...

Page 20: ...6 90 bar Si el regulador falla la presi n transmitida a la herramienta no debe exceder los 13 79 bar La herramienta puede explotar lo cual puede ocasionar la muerte o graves lesiones personales GUARD...

Page 21: ...ambos sentidos sin atascarse o pegarse 4 Reconecte la clavadora a la fuente de suministro de aire 5 Presione el Elemento de Contacto de Trabajo contra la superficie de trabajo sin apretar el gatillo L...

Page 22: ...adecuados Cuando ordene piezas de repuesto o sujetadores especifique el n mero de la pieza Para reparar la herramienta La herramienta deber ser reparada nicamente por personal calificado y deber n us...

Page 23: ...ecanismo de impulso en el cargador 3 Debe limpiar el cargador 4 El resorte del mecanismo de impulso est da ado 4 Debe reemplazar el resorte 5 El flujo de aire hacia la herramienta es inadecuado 5 Cheq...

Page 24: ...parte del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de segurid...

Reviews: