background image

GENEral

a .  

To reduce the risks of 
electric shock, fire, and 
injury to persons, read all 
the instructions before 
using the tool.

b .   Be thoroughly familiar with the 

controls and the proper use of the 
equipment . Follow all instructions . 
Contact your Campbell Hausfeld 
representative if you have any 
questions .

c .   Only persons well acquainted with 

these rules of safe operation should 
be allowed to use the unit .

 

Read and  

  understand tool 

labels and manual. Failure to follow 
warnings, dangers, and cautions could 
result in DEATH or SERIOUS INJURY.

WorK arEa

a .  

Keep the work area clean and well 
lighted. 

Cluttered benches and dark 

areas increase the risks of electric 
shock, fire, and injury to persons . 

b .  

Do not operate the tool 
in explosive atmospheres, 
such as in the presence 
of flammable liquids, 
gases, or dust. 

The tool is 

able to create sparks resulting in the 
ignition of the dust or fumes . 

c .   

Keep bystanders, children, and 
visitors away while operating the 
tool.

 Distractions are able to result in 

the loss of control of the tool . 

pErSoNal SafETY

a .  

Stay alert. Watch what you are 
doing and use common sense 
when operating the tool. Do not 
use the tool while tired or under 
the influence of drugs, alcohol, 
or medication. 

A moment of 

inattention while operating the 
tool increases the risk of injury to 
persons . 

b .  

Dress properly. Do not wear loose 
clothing or jewelry. Contain long 
hair. Keep hair, clothing, and 
gloves away from moving parts. 

Loose clothes, jewelry, or long 
hair increases the risk of injury to 
persons as a result of being caught 
in moving parts . 

c .   

Avoid unintentional starting. 
Be sure the switch is off before 
connecting to the air supply. 

Do not 

carry the tool with your finger on 
the switch or connect the tool to th 
air supply with the switch on . 

d .  

Do not overreach. Keep proper 
footing and balance at all times. 

Proper footing and balance enables 
better control of the tool in 
unexpected situations . 

2

Operating Instructions

www.chpower.com

important Safety instructions 

(Continued) 

e .  

Use safety equipment. 

A dust mask, 

non-skid safety shoes and a hard 
hat must be used for the applicable 
conditions . 

f .   

Always wear eye 
protection.

 

g .  

Always wear hearing 
protection when using 
the tool. 

Prolonged 

exposure to high intensity 
noise is able to cause 
hearing loss . 

h .  

Do not attach the hose or tool to 
your body. 

Attach the hose to the 

structure to reduce the risk of loss of 
balance if the hose shifts .

i .   

Always assume that the tool 
contains fasteners. 

Do not point 

the tool toward yourself or anyone 
whether it contains fasteners or not . 

j .   

  

Do not nail on 

  top of another 

nail. This is able to cause the nail to 
be deflected and hit someone, or 
cause the tool to react and result in a 
risk of injury to persons.

k .

  

 

Remove finger 

  from the trigger 

when not driving fasteners. Never 
carry the tool with finger on trigger, 
the tool is able to fire a fastener. 
Activate the trigger lock when not in 
use.

 

Always remain in a 

  firmly balanced 

position when using or handling the 
tool.

Tool Components and Specifications

 

  • 

rEqUirES: 

0 .15 average SCFM with 10 

fasteners per minute @ 90 psi

  •  

air iNlET: 

1/4 inch NPT 

  • 

STaplE SiZE raNGE:

 1/4 inch to 9/16 inch

  • 

MaGaZiNE CapaCiTY: 

100+ Arrow

®

 T50

®

 staples or 

equivalent (see Fastener Section)

  • 

WEiGHT:

 2 lbs ., 1 oz .

  • 

lENGTH: 

8-1/2 inch

  • 

HEiGHT: 

5-5/8 inch 

  • 

MaXiMUM prESSUrE:

 100 psi

  • 

prESSUrE raNGE:

 60 psi – 100 psi

Adjustable Cap Exhaust

Trigger 

Lock

Magazine

Trigger

Fastener Discharge Area

Latch 

Lever

Summary of Contents for CHN10610

Page 1: ...dicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or...

Page 2: ...ff before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to th air supply with the switch on d Do not overreach Keep proper footing and balance a...

Page 3: ...measures reduce the risk of injury to persons e Store the tool when it is idle out of reach of children and other untrained persons A tool is dangerous in the hands of untrained users f Maintain the t...

Page 4: ...gulated compressed air source to limit the air pressure supplied to the tool The regulated pressure must not exceed 100 psi If the regulator fails the pressure delivered to the tool must not exceed 20...

Page 5: ...l from service Unloading is the reverse of loading except always disconnect the air hose before unloading Adjusting The Direction Of The Exhaust The tool is equipped with an adjustable direction exhau...

Page 6: ...n piston or lack of lubrication 6 Replace and lubricate o rings 7 Damaged O Ring on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten screws and fittings 9 Cap gasket leaking 9 Replace gasket Tool...

Page 7: ...7 CHN10610 www chpower com Notes...

Page 8: ...ons provided in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteratio...

Page 9: ...er indique une situation hasardeuse imminente qui R SULTERA en perte de vie ou blessures graves Avertissement indique une situation hasardeuse potentielle qui PEUT r sulter en perte de vie ou blessure...

Page 10: ...d arr t off avant de brancher l alimentation d air Ne pas transporter l outil avec le doigt sur l interrupteur ni brancher l outil l alimentation d air avec l interrupteur en marche d Ne pas trop se p...

Page 11: ...t mener la mort ou de graves blessures Ne toucher la g chette qu au moment de poser des attaches Ne jamais attacher de conduite d air l outil ni transporter l outil en touchant la g chette L outil pou...

Page 12: ...pourrait provoquer des blessures graves voire la mort Utiliser seulement une source d air comprim pression pour limiter la pression d air fournie l outil La pression contr l e ne doit pas d passer 69...

Page 13: ...etirer tous les agrafes du chargeur avant de ranger la agrafeuse L op ration de d chargement s effectue l inverse de l op ration de chargement mais il faut toujours d brancher le tuyau d air comprim A...

Page 14: ...ou manque de lubrification 6 Remplacer les joints torique 7 Joint torique de la soupape de g chette endommag 7 Remplacer les joints torique 8 Fuites d air 8 Serrer les vis et raccords 9 Fuite du join...

Page 15: ...15 Fr CHN10610 Notes...

Page 16: ...usive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces apparei...

Page 17: ...sto le indica que hay una situaci n inmediata que LE OCASIONARIA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad sto le indi...

Page 18: ...nflamables La herramienta puede crear chispas y provocar la ignici n de polvo o vapores c Mantenga alejados a los observadores ni os y visitantes mientras hace funcionar la herramienta Las distraccion...

Page 19: ...r en muerte o graves lesiones personales No toque el gatillo a menos que se est n clavando sujetadores Nunca conecte la l nea de aire a la herramienta ni mueva la herramienta cuando est tocando el gat...

Page 20: ...puede ocasionar la muerte o graves lesiones personales Use solamente una fuente de aire comprimido de presi n regulada para limitar la presi n de aire suministrada a la herramienta La presi n regulad...

Page 21: ...cio La descarga se hace siguiendo el proceso inverso de la carga sin embargo siempre se tiene que desconectar la manguera de aire antes de descargarla para ajustar la direccion del tubo de escape La h...

Page 22: ...ebe reemplazar los anillos en O Lubr quelos 7 Los anillos en O de la v lvula del gatillo est n da ados 7 Debe reemplazar los anillos en O 8 Hay fugas de aire 8 Debe apretar los tornillos y las conexio...

Page 23: ...23 Sp CHN10610 Notas...

Page 24: ...comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad Si dic...