background image

Never carry the tool by 
the air hose or pull the 
hose to move the tool or 
a compressor. Keep hoses 
away from heat, oil and 
sharp edges. Replace any 
hose that is damaged, weak or worn. 
Personal injury or tool damage could 
occur.
 

Always assume the  

  tool contains 

fasteners. Respect the tool as a working 
implement; no horseplay. Always keep 
others at a safe distance from the work 
area in case of accidental discharge of 
fasteners. Do not point the tool toward 
yourself or anyone whether it contains 
fasteners or not. Accidental triggering 
of the tool could result in death or 
serious personal injury. 
 

Do not operate or allow 
anyone else to operate 
the tool if any warnings or warning 
labels are not legible. Warnings or 
warning labels are located on the tool 
magazine and body. 
 

Do not drop or  

  throw the tool. 

Dropping or throwing the tool can 
result in damage that will make the tool 
unusable or unsafe. If the tool has been 
dropped or thrown, examine the tool 
closely for bent, cracked or broken parts 
and air leaks. STOP and repair before 
using or serious injury could occur.
 

Avoid using the  

  tool when the 

magazine is empty. Accelerated wear on 
the tool may occur.
 

Clean and check all  

  air supply hoses 

and fittings before connecting the 
tool to an air supply. Replace any 
damaged or worn hoses or fittings. 
Tool performance or durability may be 
reduced.

SErviCE

a .  

Tool service must be performed only 
by qualified repair personnel. 

b .  

When servicing a tool, use only 
identical replacement parts. Use 
only authorized parts. 

 

Avoid long extended  

  periods of work 

with the tool. Stop using the tool if you 
feel pain in hands or arms.

Tool USE aND CarE

a .  

Use clamps or another practical way 
to secure and support the workpiece 
to a stable platform. 

Holding the 

work by hand or against the body is 
unstable and is able to lead to loss 
of control . 

b .  

Do not force the tool. 

Use the 

correct tool for the application . The 
correct tool will do the job better 
and safer at the rate for which the 
tool is designed . 

c .   

Do not use the tool if the switch 
does not turn the tool on or off. 

Any 

tool that cannot be controlled with 
the switch is dangerous and must be 
repaired . 

d .  

  

Disconnect the 

  tool from the air 

source before making adjustments, 
doing tool maintenance, clearing 
jams, leaving work area,loading, 
or unloading the tool.

 

Such 

precautionary measures reduce the 
risk of injury to persons .

e .  

Store the tool when it is idle out 
of reach of children and other 
untrained persons. 

A tool is 

dangerous in the hands of untrained 
users . 

f .   

Maintain the tool with care. 

properly maintained tool reduces 
the risk of problems and is easier to 
control . 

g .  

Check for misalignment or binding 
of moving parts, breakage of parts, 
and any other condition that affects 
the tool’s operation. 

If damaged, 

have the tool serviced before using . 
Many accidents are caused by poorly 
maintained tools . There is a risk of 
bursting if the tool is damaged . 

h .  

Use only those fasteners listed 
in the Accessories section of this 
manual. 

Fasteners not identified 

for use with this tool by the tool 
manufacturer are able to result in 
a risk of injury to persons or tool 
damage when used in this tool .

i .    Selecting an appropriate tool 

actuation system, taking into 
consideration the work application 
for which the tool is used .

 

 

Never use 

  gasoline 

or other flammable liquids 
to clean the tool. Never use 
the tool in the presence of 
flammable liquids or gases. Vapors 
could ignite by a spark and cause an 
explosion which will result in death or 
serious personal injury.

Do not remove, tamper 
with, or otherwise cause 
the trigger lock or trigger 
to become inoperable. Do not operate 
any tool which has been modified in a 
like fashion. Death or serious personal 
injury could result.

 

Do 

  not 

touch the trigger unless 
driving fasteners. Never 
attach air line to tool or 
carry tool while touching the trigger. 
The tool could eject a fastener which 
will result in death or serious personal 
injury. Also actuate the trigger lock to 
the safe position when not in use.

Always disconnect the 
tool from the power 
source when unattended, 
performing any maintenance or repair, 
clearing a jam, loading, unloading or 
moving the tool to a new location. Do 
not load the tool with fasteners when 
the trigger is depressed. The tool could 
eject a fastener causing death or serious 
personal injury.

Always fit tool with a fitting near 
the tool in such a manner that all 
compressed air in the tool is discharged 
at the time the fitting is disconnected. 
Do not use a check valve or any other 
fitting which allows air to remain in the 
tool. Death or serious personal injury 
could occur.

Never place hands or any 
other body parts in the 
fastener discharge area of 
the tool. The tool might eject a fastener 
and could result in death or serious 
personal injury.

3

CHN10610

www.chpower.com

important Safety instructions 

(Continued) 

!

WARNING

Summary of Contents for CHN10610

Page 1: ...dicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or...

Page 2: ...ff before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to th air supply with the switch on d Do not overreach Keep proper footing and balance a...

Page 3: ...measures reduce the risk of injury to persons e Store the tool when it is idle out of reach of children and other untrained persons A tool is dangerous in the hands of untrained users f Maintain the t...

Page 4: ...gulated compressed air source to limit the air pressure supplied to the tool The regulated pressure must not exceed 100 psi If the regulator fails the pressure delivered to the tool must not exceed 20...

Page 5: ...l from service Unloading is the reverse of loading except always disconnect the air hose before unloading Adjusting The Direction Of The Exhaust The tool is equipped with an adjustable direction exhau...

Page 6: ...n piston or lack of lubrication 6 Replace and lubricate o rings 7 Damaged O Ring on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten screws and fittings 9 Cap gasket leaking 9 Replace gasket Tool...

Page 7: ...7 CHN10610 www chpower com Notes...

Page 8: ...ons provided in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteratio...

Page 9: ...er indique une situation hasardeuse imminente qui R SULTERA en perte de vie ou blessures graves Avertissement indique une situation hasardeuse potentielle qui PEUT r sulter en perte de vie ou blessure...

Page 10: ...d arr t off avant de brancher l alimentation d air Ne pas transporter l outil avec le doigt sur l interrupteur ni brancher l outil l alimentation d air avec l interrupteur en marche d Ne pas trop se p...

Page 11: ...t mener la mort ou de graves blessures Ne toucher la g chette qu au moment de poser des attaches Ne jamais attacher de conduite d air l outil ni transporter l outil en touchant la g chette L outil pou...

Page 12: ...pourrait provoquer des blessures graves voire la mort Utiliser seulement une source d air comprim pression pour limiter la pression d air fournie l outil La pression contr l e ne doit pas d passer 69...

Page 13: ...etirer tous les agrafes du chargeur avant de ranger la agrafeuse L op ration de d chargement s effectue l inverse de l op ration de chargement mais il faut toujours d brancher le tuyau d air comprim A...

Page 14: ...ou manque de lubrification 6 Remplacer les joints torique 7 Joint torique de la soupape de g chette endommag 7 Remplacer les joints torique 8 Fuites d air 8 Serrer les vis et raccords 9 Fuite du join...

Page 15: ...15 Fr CHN10610 Notes...

Page 16: ...usive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces apparei...

Page 17: ...sto le indica que hay una situaci n inmediata que LE OCASIONARIA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad sto le indi...

Page 18: ...nflamables La herramienta puede crear chispas y provocar la ignici n de polvo o vapores c Mantenga alejados a los observadores ni os y visitantes mientras hace funcionar la herramienta Las distraccion...

Page 19: ...r en muerte o graves lesiones personales No toque el gatillo a menos que se est n clavando sujetadores Nunca conecte la l nea de aire a la herramienta ni mueva la herramienta cuando est tocando el gat...

Page 20: ...puede ocasionar la muerte o graves lesiones personales Use solamente una fuente de aire comprimido de presi n regulada para limitar la presi n de aire suministrada a la herramienta La presi n regulad...

Page 21: ...cio La descarga se hace siguiendo el proceso inverso de la carga sin embargo siempre se tiene que desconectar la manguera de aire antes de descargarla para ajustar la direccion del tubo de escape La h...

Page 22: ...ebe reemplazar los anillos en O Lubr quelos 7 Los anillos en O de la v lvula del gatillo est n da ados 7 Debe reemplazar los anillos en O 8 Hay fugas de aire 8 Debe apretar los tornillos y las conexio...

Page 23: ...23 Sp CHN10610 Notas...

Page 24: ...comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad Si dic...

Reviews:

Related manuals for CHN10610