background image

5

CHN10610

www.chpower.com

operating instructions 

(Continued) 

3 .   Always use air supply hoses with a 

minimum working pressure rating 
equal to or greater than the pressure 
from the power source if a regulator 
fails, or 150 psi, whichever is greater . 
Use 1/4 in . air hose for runs up to 50 
ft . Use 3/8 in . air hoses for 50 ft . run 
or longer . For better performance, 
install a 3/8 in . quick plug (1/4 in . NPT 
threads) with an inside diameter of 
 .315 in . (8mm) on the tool and a 3/8 
in . quick coupler on the air hose .

4 .   Use a pressure regulator on the 

compressor, with an operating 
pressure of 0 psi - 125 psi . A pressure 
regulator is required to control 
the operating pressure of the tool 
between 60 psi and 100 psi . 

opEraTioNal MoDE

 

Always know the  

  operational mode of 

the tool before using. Failure to know 
the operational mode could result in 
death or serious personal injury.

TriGGEr oNlY MoDE (WiTH 
TriGGEr loCK)

The tool is a single-actuator device . This 
mode requires that, with the trigger 
lock not positioned in the safe mode, 
only a pull of the trigger will fire a 
fastener .
After verifying there are no fasteners 
in the tool, safety check the operation 
of the activated trigger lock to prevent 
the tool from firing a fastener before 
storage . Always disconnect from 
compressed air when not in use .

loaDiNG/UNloaDiNG THE Tool

1 .   Always 

disconnect

 the tool from 

the air supply 

before loading

 

fasteners .

2 .   Turn stapler upside 

down and pull the 
latch . Pull back on the 
magazine cover .

3 .   Insert a stick of 

Arrow

®

 T50

®

 staples 

or equivalent (see 
Fastener Section) into the magazine 
with the crown side down . Make 
sure the staples are not dirty or 
damaged .

4 .   Push the magazine 

cover forward until 
the latch catches .

5 .   Always unload all 

fasteners before 
removing tool from 
service .  Unloading 
is the reverse of 
loading, except always disconnect 
the air hose before unloading .

aDJUSTiNG THE DirECTioN of THE 
EXHaUST

The tool is 
equipped with 
an adjustable 
direction exhaust 
deflector . This is intended to allow the 
user to change the direction of the 
exhaust . Simply twist the deflector to 
any direction desired .

ClEariNG a JaM froM THE Tool

1 .   Disconnect the air 

supply from the tool .

2 .   Remove all fasteners from the 

magazine (see "Loading/ Unloading 
The Tool") .  

3 .   With the magazine open, remove 

the jammed fastener, using pliers, a 
screwdriver or a pick if required .

4 .   Close magazine .

User-Maintenance 

instructions

TECHNiCal SErviCE

Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding 
the operation or repair of this tool or 
for additional copies of this manual .

faSTENEr aND rEplaCEMENT 
parTS

 

Use only Arrow

®

 T50

®

  or equivalent staples. 

Tool performance, safety and durability 
could be reduced if improper fasteners 
are used. When ordering replacement 
parts or fasteners, specify by part 
number.

Tool rEpair

Only qualified personnel should repair 
the tool and they should use genuine 
Campbell Hausfeld replacement parts 
and accessories, or parts and accessories 
which perform equivalently .

aSSEMblY proCEDUrE for SEalS

When repairing a tool, the internal parts 
must be cleaned and lubricated . Parker 
O-lube or equivalent must be used on 
all o-rings . Each o-ring must be coated 
with O-lube before assembling . A small 
amount of oil must be used on all moving 
surfaces and pivots . After reassembling, 
a few drops of 30W non-detergent oil or 
equivalent, must be added through the 
air line before testing .

SToraGE

The stapler should be stored in a cool 
dry place .  

fasteners

Fasteners used in this stapler include:

•  Arrow

®

 T50

®

 staples or any 

equivalent fastener with the 
approximate dimensions illustrated 
below .

150 psi or greater

3/8 inch I .D .

rotate

10 .7 mm

6 mm - 14 mm

1/4 inch - 9/16 inch

1 .3 mm

0 .7 mm

9 .3 mm

Summary of Contents for CHN10610

Page 1: ...dicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or...

Page 2: ...ff before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to th air supply with the switch on d Do not overreach Keep proper footing and balance a...

Page 3: ...measures reduce the risk of injury to persons e Store the tool when it is idle out of reach of children and other untrained persons A tool is dangerous in the hands of untrained users f Maintain the t...

Page 4: ...gulated compressed air source to limit the air pressure supplied to the tool The regulated pressure must not exceed 100 psi If the regulator fails the pressure delivered to the tool must not exceed 20...

Page 5: ...l from service Unloading is the reverse of loading except always disconnect the air hose before unloading Adjusting The Direction Of The Exhaust The tool is equipped with an adjustable direction exhau...

Page 6: ...n piston or lack of lubrication 6 Replace and lubricate o rings 7 Damaged O Ring on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten screws and fittings 9 Cap gasket leaking 9 Replace gasket Tool...

Page 7: ...7 CHN10610 www chpower com Notes...

Page 8: ...ons provided in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteratio...

Page 9: ...er indique une situation hasardeuse imminente qui R SULTERA en perte de vie ou blessures graves Avertissement indique une situation hasardeuse potentielle qui PEUT r sulter en perte de vie ou blessure...

Page 10: ...d arr t off avant de brancher l alimentation d air Ne pas transporter l outil avec le doigt sur l interrupteur ni brancher l outil l alimentation d air avec l interrupteur en marche d Ne pas trop se p...

Page 11: ...t mener la mort ou de graves blessures Ne toucher la g chette qu au moment de poser des attaches Ne jamais attacher de conduite d air l outil ni transporter l outil en touchant la g chette L outil pou...

Page 12: ...pourrait provoquer des blessures graves voire la mort Utiliser seulement une source d air comprim pression pour limiter la pression d air fournie l outil La pression contr l e ne doit pas d passer 69...

Page 13: ...etirer tous les agrafes du chargeur avant de ranger la agrafeuse L op ration de d chargement s effectue l inverse de l op ration de chargement mais il faut toujours d brancher le tuyau d air comprim A...

Page 14: ...ou manque de lubrification 6 Remplacer les joints torique 7 Joint torique de la soupape de g chette endommag 7 Remplacer les joints torique 8 Fuites d air 8 Serrer les vis et raccords 9 Fuite du join...

Page 15: ...15 Fr CHN10610 Notes...

Page 16: ...usive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces apparei...

Page 17: ...sto le indica que hay una situaci n inmediata que LE OCASIONARIA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad sto le indi...

Page 18: ...nflamables La herramienta puede crear chispas y provocar la ignici n de polvo o vapores c Mantenga alejados a los observadores ni os y visitantes mientras hace funcionar la herramienta Las distraccion...

Page 19: ...r en muerte o graves lesiones personales No toque el gatillo a menos que se est n clavando sujetadores Nunca conecte la l nea de aire a la herramienta ni mueva la herramienta cuando est tocando el gat...

Page 20: ...puede ocasionar la muerte o graves lesiones personales Use solamente una fuente de aire comprimido de presi n regulada para limitar la presi n de aire suministrada a la herramienta La presi n regulad...

Page 21: ...cio La descarga se hace siguiendo el proceso inverso de la carga sin embargo siempre se tiene que desconectar la manguera de aire antes de descargarla para ajustar la direccion del tubo de escape La h...

Page 22: ...ebe reemplazar los anillos en O Lubr quelos 7 Los anillos en O de la v lvula del gatillo est n da ados 7 Debe reemplazar los anillos en O 8 Hay fugas de aire 8 Debe apretar los tornillos y las conexio...

Page 23: ...23 Sp CHN10610 Notas...

Page 24: ...comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad Si dic...

Reviews: