background image

tool uSe aNd Care

a.  

Do not force the tool.

 Use the correct tool for the application. 

The correct tool will do the job better and safer at the rate for 
which the tool is designed. 

  

Disconnect the tool from the air source before   

  making adjustments, doing tool maintenance, 

clearing jams, leaving work area, loading, or unloading the tool. Such 
precautionary measures reduce the risk of injury to persons. 

b.  

Store the tool when it is idle out of reach of children and 
other untrained persons

. A tool is dangerous in the hands of 

untrained users. 

c.  

Maintain the tool with care.

 A properly maintained tool 

reduces the risk of problems and is easier to control. 

d. 

Use only those fasteners listed in the “Fastener Interchange 
Information” section on page 12 
of this manual. 

Fasteners 

not identified for use with this tool by the tool manufacturer 
are able to result in a risk of injury to persons or tool damage 
when used in this tool.

e. 

Always work in a well-ventilated area. Wear oSHA-
approved dust mask.

 

 

Always disconnect the tool from the power  

  source when unattended, performing any 

maintenance or repair, clearing a jam, loading, unloading , or moving 
the tool to a new location. 

 

 

Always fit tool with a fitting or hose coupling  

  on or near the tool in such a manner that all 

compressed air in the tool is discharged at the time the fitting or hose 
coupling is disconnected. Do not use a check valve or any other fitting 
which allows air to remain in the tool. Death or serious personal 
injury could occur.
 

 

Never carry the tool by the air hose or pull   

  the hose to move the tool or a compressor. Keep 

hoses away from heat, oil and sharp edges. Replace any hose that is 
damaged, weak or worn. Personal injury or tool damage could occur.

 

 

Do not drive a fastener on top of other fastener.   

  The fastener could glance and cause death or a 

serious puncture wound. 

f. 

This tool must NoT be modified or used for any application 
other than that for which it was designed.

g.   Do not remove any labels from the tool.

h.   Do not modify or alter the tool or any tool parts. Do not use 

the tool if any shields or guards are removed or altered. 

Do 

not use the tool as a hammer. Personal injury or tool damage 
may occur.

    

Do not use any type of flammable gases or   

  oxygen as a power source for the tool.  

Use filtered, lubricated, regulated compressed air only. Use of a 
compressed gas instead of compressed air may cause the tool to 
explode which will cause death or serious personal injury.
    

Never use gasoline or other flammable liquids   

  to clean the tool. Never use the tool in the 

presence of flammable liquids or gases. Vapors could ignite by a spark 
and cause an explosion which will result in death or serious personal 
injury.

PerSoNal SaFety

a.  

Stay alert. Watch what you are doing and use common 
sense when operating the tool. Do not use the tool 
while tired or under the influence of drugs, alcohol, or 
medication. 

A moment of inattention while operating the 

tool increases the risk of injury to persons. 

b.  

Dress properly. Do not wear loose clothing or jewelry. 
Contain long hair. Keep hair, clothing, and gloves away 
from moving parts. 

Loose clothes, jewelry, or long hair 

increases the risk of injury to persons as a result of being 
caught in moving parts. 

c.  

Do not overreach. Keep proper footing and 
balance at all times. 

Proper footing and balance 

enables better control of the tool in unexpected 
situations. 

d.  

Use safety equipment. 

A dust mask, non-skid safety shoes 

and a hard hat must be used for the applicable conditions. 

 

Ensuring that the tool is used 

  only when the operator and all 

other personnel in the work area are wearing ANSI Z87 
eye protection equipment, and when required, other 
appropriate protection equipment such as head, hearing 
and foot protection equipment. Serious eye or permanent hearing 
loss could result.

e.  

Always wear hearing protection when using the 
tool. 

Prolonged exposure to high intensity noise 

is able to cause hearing loss. 

f.  

Do not attach the hose or tool to your body. 

Attach the hose to the structure to reduce the risk of loss of 
balance if the hose shifts.

g.  

Always assume that the tool contains fasteners. 

Do not point the tool toward yourself or anyone 
whether it contains fasteners or not. 

   

Do not drop or throw the tool. Dropping 

  or throwing the tool can result in damage that 

will make the tool unusable or unsafe. If the tool has been dropped 
or thrown, examine the tool closely for bent, cracked or broken parts 
and air leaks. STOP and repair before using or serious injury could 
occur.

   

Avoid long extended periods of work with the  

  tool. Stop using the tool if you feel pain in 

hands or arms.
   

Hold tool by insulated gripping surface when  

  performing an operation where the tool or 

fastener may contact hidden wiring. Contacting a “live” wire will 
make exposed metal parts of the tool “live” and shock the operator.
 

Never place hands or any other  

  body part in the fastener discharge 

area of the tool. The tool might eject a fastener and could 
result in death or serious personal injury.

eleCtrICal SaFety

 

The front end of the tool may be    

  made “live” if the tool comes 

into contact with live wiring in the wall. TO PREVENT 
ACCIDENTAL ELECTRICAL SHOCK, HOLD TOOL ONLY 
BY THE SOFT GRIP HANDLE.

CHN71600

www.chpower.com

Important Safety Information (Continued)

 

Operating Instructions and Parts Manual

5

Summary of Contents for CHN71600

Page 1: ...3 8 inch Stapler Fran aise Page 17 Espa ol p gina 33 MAKES IT EASY TO DO IT LIKE A PRO chpower com Operating Instructions and Parts Manual CHN71600 IN729800AV 3 10 2010 Campbell Hausfeld Scott Fetzer...

Page 2: ...up 9 Hook up Instructions For Stapler to Air Supply 9 Air Hose Requirements 9 Loading Unloading The Stapler 10 Loading the Stapler 10 Unloading the Stapler 10 Operation 10 Operational Mode 10 Trigger...

Page 3: ...ifications Model CHN71600 Requires 0 2 Avg SCFM using 10 fasteners per minute at 90 psi Air Inlet 1 4 inch NPT Fastener Size Range 1 4 inch to 9 16 inch Arrow T50 staples See fastener interchange sect...

Page 4: ...result in DEATH or SERIOUS INJURY b Be thoroughly familiar with the controls and the proper use of the equipment Follow all instructions Contact your Campbell Hausfeld representative if you have any...

Page 5: ...ence of flammable liquids or gases Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury Personal Safety a Stay alert Watch what you are doing and...

Page 6: ...re capable of explosion and serious injury to persons Air compressors providing air to the tool should follow the requirements established by theAmerican National Standards Institute Standard B19 3 19...

Page 7: ...pressure The maximum allowable pressure of compressed air as specified by the manufacture for operating the tool psi Pounds per Square Inch Measurement of the pressure exerted by the force of the air...

Page 8: ...y position that is convenient for the user Turn the deflector to any direction desired Rubber Comfort Grip Helps to maintain a steady grip and prevents fatigue Figure 4 Components of the Stapler CHN71...

Page 9: ...for the tool NOTE For better performance install a 3 8 inch quick plug 1 4 inch NPT threads with an inside diameter of 0 315 inch 8 mm on the tool and a 3 8 inch quick coupler on the air hose 1 With O...

Page 10: ...s 1 Press down on latch and pull back on the magazine cover 2 Remove fasteners 3 Push the magazine cover forward until the latch catches www chpower com Operating Instructions and Parts Manual 10 Figu...

Page 11: ...s or parts and accessories which perform equivalently Replacement Parts Use only genuine Campbell Hausfeld service parts Tool performance safety and durability could be reduced if improper parts are u...

Page 12: ...CHN71600 www chpower com Operating Instructions and Parts Manual 12 Notes...

Page 13: ...e prevent staples or pusher from moving freely in magazine 3 Clean magazine 4 Damaged pusher spring 4 Replace spring 5 Inadequate air flow to stapler 5 Check fitting hose or compressor 6 Worn ring on...

Page 14: ...f any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A 2 3 5 6 10 11 1 4 7 8 9 9 12 13 14 15 16 17 18 19 20 21 22 23 28 29 30 31 60...

Page 15: ...r valve stem 1 34 Trigger safety 1 35 Trigger spring n 1 36 Split washer 2 37 Trigger 1 38 Pin 1 39 Recoil decal housing 1 40 Spring pin 2 Ref Part No Description No Qty Ref Part No Description No Qty...

Page 16: ...te products in accordance with instructions provided in the owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions sha...

Page 17: ...3 8 po 9 5 mm English Page 1 Espa ol p gina 33 VOUS PERMET DE LE FAIRE COMME UN PROFESSIONNEL chpower com Instructions d Utilisation et Manual de Pi ces CHN71600 IN729800AV 3 10 2010 Campbell Hausfeld...

Page 18: ...F 25 Composants minimaux requis pour le raccord F 25 Instructions de branchement de l outil l alimentation d air F 25 Exigences du tuyau air F 25 Charger d charger l outil F 26 Charger l outil F 26 D...

Page 19: ...14 kPa 690 kPa Trouver le num ro de mod le et le code de date sur le chargeur et ou le corps de l outil Inscrire plus bas N du Mod le ________________________ Code Date ___________________________ Con...

Page 20: ...rait causer la mort ou de graves blessures Ne pas apporter de modifications l outil sans d abord obtenir une approbation crite de Campbell Hausfeld N utilisez pas une cloueuse si les crans ou protecte...

Page 21: ...harger une attache menant la mort ou de graves blessures CHN71600 Importantes Instructions De S curit Suite S CURIT LECTRIQUE L avant de l outil pourrait tre plac sous tension si l outil entre en cont...

Page 22: ...urs v rifier avant d utiliser l outil que la source d air est ajust e la pression d air nominale ou dans la plage de pression d air nominale b Ne jamais utiliser d oxyg ne de dioxyde de carbone de gaz...

Page 23: ...ale La pression d air comprim maximale permise tel qu indiqu par le fabricant pour utiliser l outil kPa Mesure de la pression de la force de l air La sortie r elle en kPa se mesure par un manom tre su...

Page 24: ...ermet de rediriger l chappement de l outil dans toute position pratique pour l utilisateur Tourner le d flecteur dans toute direction voulue Prise confortable de caoutchouc Aide maintenir une prise so...

Page 25: ...outil REMARQUE Pour une meilleure performance installer un bouchon rapide de 9 5 mm 3 8 po filets 1 4 po NPT avec un diam tre int rieur de 8 mm 0 315 po sur l outil et un coupleur rapide de 9 5 mm 3 8...

Page 26: ...e d charger les attaches 1 Enfoncer le verrou et reculer le couvercle du chargeur 2 Retirer les attaches 3 Enfoncer le couvercle du chargeur vers l avant jusqu ce que le loquet s engage Installation s...

Page 27: ...DE RECHANGE Utiliser seulement des pi ces de rechange de Campbell Hausfeld La performance de l outil la s curit et la durabilit pourraient tre r duites avec des pi ces inappropri es En commandant des...

Page 28: ...CHN71600 Instructions d Utilisation et Manual de Pi ces F 28 Notes...

Page 29: ...le poussoir de se d placer librement dans le chargeur 3 Nettoyer le chargeur 4 Ressort de poussoir endommag 4 Remplacer le ressort 5 Circulation d air inad quate l outil 5 V rifier le raccord le boyau...

Page 30: ...imprim sur l outil Attn Customer Service Description de la pi ce et son num ro 100 Production Drive Harrison OH 45030 U S A CHN71600 F 30 Figure 11 Illustration des pi ces de r paration pour toutes le...

Page 31: ...soupape de g chette 1 34 S curit de g chette 1 35 Ressort de g chette n 1 36 Rondelle fendue 2 37 G chette 1 38 Goupille 1 39 Bo tier d calque de rappel 1 40 Goupille ressort 2 No de Num ro R f Descri...

Page 32: ...le s manuel s accompagnant le produit Un accident l utilisation abusive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou...

Page 33: ...de 9 5 mm 3 8 pulg English page 1 Fran aise Page 17 LE FACILITA TRABAJAR COMO UN PROFESIONAL chpower com Manual de Instrucciones y Lista de Piezas CHN71600 IN729800AV 3 10 2010 Campbell Hausfeld Scot...

Page 34: ...Instrucciones para la conexi n de la herramienta al suministro de aire S 41 Requerimientos para la manguera de aire S 41 Para cargar y descargar la herramienta S 42 Para cargar la herramienta S 42 Pa...

Page 35: ...rom con 10 sujetadores por minuto a 6 21 bar 90 psi Entrada de Aire 0 64 cm NPT 1 4 pulg Tama os de los sujetadores Grapas Arrow T50 flecha de 6 4 mm 1 4 pulg a 14 3 mm 9 16 pulg consulte la secci n d...

Page 36: ...icaci n a la herramienta sin obtener primero la aprobaci n por escrito de Campbell Hausfeld No use la herramienta si le faltan alguna de las tapas protectoras o si stas han sido modificadas No use la...

Page 37: ...a causar la muerte o una lesi n personal grave CHN71600 Importantes Instrucciones De Seguridad Continuaci n SEGURIDAD EL CTRICA El extremo delantero de la herramienta puede conducir corriente si la h...

Page 38: ...n otro l quido inflamable para limpiar la herramienta Nunca use la herramienta cuando haya l quidos o gases inflamables Los vapores podr an ser encendidos por una chispa y provocar una explosi n la cu...

Page 39: ...mprimido permisible seg n lo especificado por el fabricante para el funcionamiento de la herramienta bar psi libras por pulgada cuadrada Unidades de medida de la presi n ejercida por la fuerza del air...

Page 40: ...ite que el orificio de salida de la herramienta se coloque en cualquier posici n que sea conveniente para el usuario Gire el deflector en la direcci n deseada C modo mango de goma Ayuda a mantener un...

Page 41: ...o instale un conector r pido de 0 95 cm 3 8 pulg roscas de 0 64 cm 1 4 pulg NPT con un di metro interno de 8 mm 0 315 pulg en la herramienta y un acoplador r pido de 0 95 cm 3 8 pulg en la manguera d...

Page 42: ...es 1 Presione hacia abajo el seguro y tire hacia atr s de la cubierta del cargador 2 Retire los sujetadores 3 Empuje la tapa del cargador hacia adelante hasta que tranque el seguro Configuraci n Conti...

Page 43: ...personal calificado y se deben usar piezas de repuesto y accesorios originales Campbell Hausfeld o piezas y accesorios que funcionen de manera equivalente PIEZAS DE REPUESTO Use nicamente piezas de r...

Page 44: ...CHN71600 Manual de Instrucciones y Lista de Piezas S 44 Notas...

Page 45: ...evan libremente en el cargador 3 Limpie el cargador 4 Resorte de empuje da ado 4 Cambie el resorte 5 Flujo de aire a la herramienta inadecuado 5 Compruebe las conexiones la manguera o el compresor 6 A...

Page 46: ...ero de serie si tiene Attn Customer Service Descripci n y n mero de la pieza como se muestra 100 Production Drive en la lista de repuestos Harrison OH 45030 U S A CHN71600 S 46 Figura 11 Ilustraci n d...

Page 47: ...gatillo 1 35 Resorte del gatillo n 1 36 Arandela partida 2 37 Gatillo 1 38 Pasador 1 39 Etiqueta adhesiva de retroceso en caja 1 40 Pasador de resorte 2 No de N mero de Ref Descripci n Repuesto Ctd No...

Page 48: ...djunta n al producto Dichos accidentes abusos por parte del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la descone...