5
Operating Instructions
NB003006
www.chpower.com
Operating Instructions
(Continued)
SEqUENTIAL TRIP SAFETY
MECHANISM
This tool is equipped with a sequential
trip safety mechanism. When the
operator depresses the Work Contact
Element (WCE) against the work surface
and then pulls the trigger, a fastener
will be driven.
OPERATING A SEqUENTIAL TRIP
NAILER
1. Release trigger and
place nose of tool
against work surface.
2. Depress the Work
Contact Element
(WCE) against the
work surface and pull
the trigger to drive a
fastener.
3. Release the trigger
and lift the tool from
the work surface
after each fastener is
driven.
CHECKING THE WORK CONTACT
ELEMENT (WCE)
Check the operation
of the Work Contact
Element (WCE) trip mechanism before
each use. The WCE must move freely
without binding through its entire
travel distance. The WCE spring must
return the WCE to its fully extended
position after being depressed. Do
not operate the nailer if the WCE trip
mechanism is not operating properly.
Personal injury may occur.
1. Disconnect the air
supply from the
nailer.
2. Remove all nails from
the magazine (see
Loading/ Unloading).
3. Make sure the trigger
and work contact
element (WCE) move
freely up and down
without sticking or
binding.
4. Reconnect air supply
to the nailer.
5. Depress the Work
Contact Element
(WCE) against the
work surface without
pulling the trigger.
The nailer
MUST NOT OPERATE
.
Do not use the tool if it operates
without pulling the trigger. Personal
injury may result.
6. Remove the nailer
from the work
surface. The Work
Contact Element
(WCE) must return to
its original down position. The nailer
MUST NOT OPERATE
. Do not use
the tool if it operates while lifted
from the work surface. Personal
injury may result.
7. Pull the trigger and
depress the work
contact element
(WCE) against the
work surface. The
nailer
MUST NOT OPERATE
.
8. Depress the Work
Contact Element
(WCE) against the
work surface. Pull the
trigger. The nailer
MUST OPERATE
.
An improperly
functioning tool
must not be used. Do not actuate the
tool unless the tool is placed firmly
against the work piece.
LOADING/UNLOADING THE NAILER
1. Always
disconnect
the tool from the
air supply before
loading
fasteners.
2. Lift up on the latch.
Pull back on the
magazine cover.
3. Insert a stick of
Campbell Hausfeld
nails or equivalent
(See Fastener Section)
into the magazine. Make sure
the pointed ends of the nails are
resting on the bottom ledge of the
magazine when loading. Make sure
the nails are not dirty or damaged.
4. Push the magazine
cover forward until
the latch catches.
5. Always unload all fasteners before
removing tool from service.
Unloading
is the reverse of loading,
except
always disconnect
the air
hose BEFORE unloading.
ADJUSTING THE NAIL PENETRATION
1. Regulate the air pressure to 60 psi at
the nailer.
2. Connect the air supply and test for
penetration by driving nails into a
sample piece of wood. If the nails do
not achieve the desired penetration,
adjust the air pressure to a higher
setting until the desired penetration
is achieved. Do not exceed 100 psi at
the nailer or durability of the nailer
will be reduced.
User - Maintenance
Instructions
CLEARING A JAM FROM THE TOOL
1. Disconnect the air
supply from the
nailer.
2. Remove all nails from
the magazine (See
Loading/ Unloading
The Nailer). Failure
to do so will cause the nails to eject
from the front of the nailer when
the nose assembly is removed.
3. Pull red tab forward
on quick clear nose.
Set aside nose door to
expose and remove
jammed fastener.
4. Reinstall nose in reverse order in
step 3.
5. Make sure the trigger
and Work Contact
Element (WCE) move
freely up and down
without sticking or
binding.
100
0
200
150
50
100
0
200
150
50