CL252100AV, CL254100AV
www.campbellhausfeld.com
3
Operation
set-up InstRuctIons
Air tools require a supply of clean, dry air
at 90 PSI (6.2 bar). An air supply system
with filter, regulator, and lubricator (FRL)
as shown in Figure 1 should be used.
Campbell Hausfeld FRL model PA2104
(3/8 inch) or PA2114 (1/2 inch) is
recommended.
Water in the air supply can damage the
tool. Drain condensate from compressor
tank and filter daily.
All hoses and fittings must be the correct
size and tightly fastened. Refer to Chart 1
for minimum sizes.
Tool Air Consumption
Hose ID
Less than 9 SCFM @ 100% usage
1/4 inch
9 to 34 SCFM @ 100% usage
3/8 inch
Greater than 34 SCFM @ 100% usage
1/2 inch
Chart 1
- Suggested minimum hose diameter to
use based on 50 ft length hose and continuous
SCFM rating of tool. The use of fittings and longer
hose may require a larger diameter hose to be
used.
attached. Loose attachments can
cause serious injury.
11. ALWAYS use attachments designed
for use with air powered tools.
Do NOT use damaged or worn
attachments.
12. Keep ALL nuts, bolts and screws
tight and ensure equipment is in safe
working condition.
13. ALWAYS secure workpiece in a vise
or clamp. Do not place hands on the
back cylinder when operating the
tool.
14. NEVER point an air tool at oneself
or any other person. Serious injury
COULD occur.
15. ALWAYS work in a well ventilated
area and wear OSHA approved dust
mask.
16. Do not use a cut-off disc mandrel on
this tool.
Option 2:
3 piece combo
Filter, Regulator, and Lubricator
Filter
Lubricator
Regulator
Option 1:
Individual components
Figure 1