Series CS Rotary Screw Compressors
www.campbellhausfeld.com
7
Unpacking
Disconnect, tag and lock out power
source then release all pressure from the
system before attempting to install, service, relocate or perform
any maintenance.
Do not lift or move unit without appropriately
rated equipment. Be sure the unit is securely
attached to lifting device used. Do not lift unit by holding onto tubes or
coolers. Do not use unit to lift other attached equipment.
Never use the wood shipping skids for mounting
the compressor.
PICKING THE LOCATION
Install and operate unit at least 36 inches from any obstructions in a
clean, ventilated area. The surrounding air temperature should not
exceed 100° F or fall below 40° F. This will ensure an unobstructed
flow of air to cool compressor and allow adequate space for
maintenance.
Do not locate the compressor air inlet near
steam, paint spray, sandblast areas or any other
source of contamination.
NOTE:
If compressor operates in a hot, moist environment, supply
compressor pump with clean, dry outside air. Supply air should be
piped in from external sources.
TANK MOUNTING
The tank should be bolted into a flat, even, concrete floor or on a
separate concrete foundation.
If using isolator pads,
do not draw bolts tight.
Allow the pads
to absorb vibrations. When isolators are used, a flexible hose or
coupling should be installed between the tank and service piping.
Failure to properly install the tank can
lead to cracks at the welded joints and
possible bursting.
Do not lift or move unit without appropriately rated equipment. Be sure the unit is securely attached to lifting device used.
Do not lift unit by holding onto tubes or coolers. Do not use unit to lift other attached equipment.
After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing or
damaged parts. Check to be sure all supplied accessories are enclosed with the unit. In case of questions, damaged or missing parts,
please call 1-855-504-5678 for customer assistance.
Do not operate unit if damaged during shipping, handling or use. Damage may result in bursting and cause injury
or property damage.
Installation
Figure 4 - Location
36 inches
36 inches
36 inches
36 inches