MAINTENANCE /
REP
AIR
TROUBLESHOOTING
OPERA
TION
ASSEMBL
Y /
INST
ALLA
TION
SAFETY /
SPECIFICA
TIONS
GETTING ST
AR
TED
11
Drain Tank
With compressor shut off and pressure released:
Drain moisture from tanks by opening drain valve
underneath tanks (See Figure 4).
Cleaning
Turn power OFF and clean dust and dirt from motor,
tank, air lines and pump cooling fins.
IMPORTANT:
Unit should be located as far from
spraying area as hose will allow to prevent over-spray
from clogging air filter.
Air Filter
Check air filter to be sure it is clean. To service a filter, remove the filter housing cover. Remove filter and
clean foam or filter in hot, soapy water (Paper filters cannot be washed). Rinse and let dry. Replace air filters
that cannot be cleaned. Place filter back in the housing base. Replace cover.
Lubrication
This is an oilless type compressor requiring no lubrication.
End of Operation/Storage
1. Turn Auto ON/OFF switch to OFF position.
2. Unplug power cord from wall outlet and wrap around handle to prevent damage when not in use.
3. Wearing safety glasses drain tank of air by pulling the ring on the safety valve. Use other hand to
deflect fast moving air from being directed toward your face.
4. Drain tank of condensation by opening drain valve on bottom of tank. Tank pressure should be below
10 PSI when draining tank.
5. Air hose should be disconnected from compressor and open end hanging down to drain condensation.
6. Compressor and hose should be stored in a cool, dry place.
Technical Service
For information regarding the operation or repair of this product, please visit www.campbellhausfeld.com.
MAINTENANCE SCHEDULE
Operation
Daily
Weekly
Drain Tank
l
Check Air Filter
l
Check Safety Valve
l
Blow Dirt from Inside Motor
l