Instructions (Continued)
4 . Check and replace any damaged
o-rings and seals . O-rings and seals
can be wiped clean but not soaked
in solvent .
5 . Unscrew packing nuts and replace
the packing ONLY if a leak will not
stop when the nut is tightened (See
Figure 5) . Do not over-tighten a
packing nut because this will restrict
movement of the needle .
6 . Re-assemble in reverse order of
above and use a non-silicone oil on
moving parts . Apply Vaseline® or
light grease on threaded joints and
hose connections .
TECHNICAL SERvICE
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual .
TOOL REPAIR
Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently .
STORAGE
1 . When not using spray gun,
turn the fluid adjustment knob
counterclockwise to open which
will reduce spring tension on needle
fluid tip .
2 . Spray gun
mUST BE
well cleaned
and lightly lubricated .
Troubleshooting Chart
Stop using tool immediately if any of the following problems occur. Serious personal injury could occur.
Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.
Symptom
Possible Cause(s)
Corrective Action
Right or left
heavy spray
pattern
1 . Holes in left or right side of the air cap
are plugged
1 . Clean . Use only non-metallic pick
2 . Dirt on left or right side of fluid tip
2 . Clean
Top or
bottom
heavy spray
pattern
1 . Dried material at top or bottom of fluid
tip
1 . Clean
2 . Loose air cap or dirty seat
2 . Clean and tighten
3 . Air cap plugged
3 . Clean . Use only non-metallic pick
Split spray
pattern
1 . Fan pattern open too far
1 . Partially close the pattern adjustment
2 . Fluid turned in too far
2 . Increase fluid
3 . Atomization air too high
3 . Reduce atomization air pressure
Center
heavy spray
pattern
1 . Fan adjustment partially closed
1 . Open fan pattern adjustment
2 . Material too thick
2 . Thin to proper viscosity
3 . Atomization pressure too low
3 . Increase atomization pressure
Sputtering
spray
1 . Material level too low
1 . Refill
2 . Container tipped too far
2 . Hold more upright
3 . Loose fluid inlet connection
3 . Tighten
4 . Loose or damaged fluid tip / seat
4 . Adjust or replace
5 . Dry or loose fluid needle packing nut
5 . Lubricate and or tighten
6 . Air vent clogged
6 . Clear vent hole
Fluid leaking from packing
nut
1 . Packing nut loose
1 . Tighten, but do not restrict needle
2 . Packing worn or dry
2 . Replace or lubricate (non-silicone oil)