background image

Summary of Contents for DP4615

Page 1: ...nit if damaged during shipping handling or use Damage may result in bursting and cause injury or property damage General Safety Since the air compressor and other components material pump spray guns filters lubricators hoses etc used make up a high pressure pump ing system the following safety pre cautions must be observed at all times la amnu 1 included with this product carefully Bethoroughly fa...

Page 2: ...o not spray flammable materials in vidnity of open flame or near ignition sources including the compressor unil_ 16 Do not smoke when spraying paint insecticides or other flammable substances 17 Use a face mask respi rator when spraying and spray in a well ven tilated area to prevent health and fire hazards 18 Do not direct paint or other sprayed material at the compressor Locate compressor as far...

Page 3: ...4 20 314 3 4 3 4 1 40 314 1 1 I 60 3 4 1 1 1 100 1 1 1 1 4 WIRING AWADPj mjr I All wiring and a_ alaal _ Wl electrical connec tions must be performed by a qualified electrician Installations must be in accordance with local and national codes IACAUTIO Overheating short 3 circuiting and fire damage will result from inadequate wiring Wiring must be installed in accordance with National Electrical Co...

Page 4: ...ring diagram Motors with frame sizes 184T 21ST 254T or 284T DO NOT have built in over load protection A magnetic starter is required Use Figure 4 wiring diagram To change to the alternate voltage on three phase motors with 2301460 ratings I Rewire motor per data plate on motor or instruction sheet 2 Check electric rating of magnetic starter and replace thermal overload Safety Valve Access Motor Fa...

Page 5: ...s 1 Open drain cock completely and run the compressor for 60 minutes See Figure 6 Cast Iron Series Breather Breather Cap Oil FillPlug Sight Gauge OilDrainPlug The Oil FillPlug will be inone of the two locationsshown ull _il Fill Plug Drain Plug Dipstick Breather_ Add Oil Max _ F II I Dipstick and Oil Fill Figure 5 Oil Fill Diagrams 2 Turn off the compressor and close drain cock The compressor is n...

Page 6: ...racks forming near the welds if a crack isdetected remove pressure from tank immediately and replace COMPRESSOR LUBRICATION See Operation Add oil asrequired The oil and oil filter should be changed every three months or after every SO0hoursof operation whichever comesfirst Only pressure lubricated pumps have an oil filter AIR FILTER Never run the compressorpump without an intake air filter norwith...

Page 7: ...Clean or replace alt filter 3 Drain oil Refill with oil of proper visCosity 4 Replace ringss g Tighten bo_ts replace gaskets or o tlngs 6 Replace c_ nder 1 Drain tank 2 Purchase dryer Air blowing out of inlet Insufficient pressure Broken first stage inlet valve t_vo stage unit Broken inlet vaFve single stage unit 1 Air demand too high 2 Leaks or restrictions in hosesor piping 3 Slipping belts Repl...

Page 8: ... warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines or damaged by contact with tools or surro...