FP Series
3
Installation
(Cont.)
compressor in a clean, well ventilated area
where the surrounding air temperature
will not be more than 100°F.
A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could obstruct
air flow.
Do not locate the
compressor air
inlet near steam, paint spray, sandblast
areas or any other source of
contamination. This debris will damage
the motor.
ELECTRICAL INSTALLATION
All wiring and
electrical
connections should be performed by a
qualified electrician. Installation must be
in accordance with local codes and
national electrical codes.
Never use an extension
cord with this product. Use
additional air hose instead
of an extension cord to
avoid power loss and permanent motor
damage. Use of an extension cord voids
the warranty.
GROUNDING INSTRUCTIONS
1. This product is for use on a nominal
120 volt circuit and has a grounding
plug that looks like the plug illustrated
in Fig. 3. Make sure the product is
connected to an outlet having the
same configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire for
electric current. This product is
equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.
!
CAUTION
!
WARNING
!
CAUTION
Improper use of
grounding plug can re-
sult in a possible risk of
electrical shock!
Do not use a
grounding adapter
with this product!
2. If repair or replacement of cord or plug
is necessary, do not connect grounding
wire to either flat blade terminal. The
wire with insulation having an external
surface that is green (with or without
yellow stripes) is the grounding wire.
Never connect
green (or green and
yellow) wire to a live terminal.
3. Check with a qualified electrician or
serviceman if grounding instructions
are not completely understood, or if in
doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.
WIRING
1. Local electrical wiring codes differ from
area to area. Source wiring, plug and
protector must be rated for at least the
amperage and voltage indicated on
motor nameplate, and meet all electrical
codes for this minimum.
2. Use a slow blow fuse or a circuit
breaker.
Overheating, short
circuiting and fire
damage will result from inadequate
wiring, etc.
NOTE:
120 volt, 15 amp units can be
operated on a 120 volt circuit under the
following conditions:
!
CAUTION
!
WARNING
!
DANGER
!
DANGER
a. No other electrical appliances or lights
are connected to the same branch
circuit.
b. Voltage supply is normal.
c. Circuit is equipped with a 15 amp
circuit breaker or a 15 amp slow blow
fuse.
3. If these conditions cannot be met or if
nuisance tripping of current
protection device occurs, it may be
necessary to operate compressor from
a 120 volt, 20 amp circuit.
Operation
Pressure Switch
- Auto/Off Switch - In
the
ON
position, the compressor shuts
off automatically when tank pressure
reaches the maximum preset pressure.
The compressor will automatically
restart when it reaches the minimum
preset pressure. In the
OFF
position,
the compressor will not operate. This
switch should be in the
OFF
position
when connecting or disconnecting the
power cord from the electrical outlet
or when changing air tools.
Regulator
- The regulator controls the
amount of air pressure released at the
hose outlet.
ASME Safety Valve
- This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
TEST
RESET
Figure 3 - Grounding Method
STOP!
Grounding
Pin
Grounded Outlet
22 Sp
Guía de Diagnóstico de Averías
Problema
Posible(s) Causa(s)
Acción a tomar
1. No hay energía eléctrica
2. Cortacircuito desconectado
3. Presostato dañado
4. La válvula de chequeo está dañada
5. La unidad se recalienta
6. Otros
1. Voltaje bajo
2. Defecto de la bobina del motor
3. Válvula de chequeo o desfogue
defectuosa
1. Fusible inadecuado, circuito
sobrecargado
2. Válvula de chequeo o desfogue
defectuosa
1. Conexiones flojas (conexiones,
tuberías, etc.)
2. La llave de drenaje está floja
3. Hay una fuga en la válvula de
chequeo
1. Hay fugas de aire en las tuberías (del
compresor o del sistema de conexión)
2. El anillo del pistón está dañado
1. ¿Está conectado? Chequée el fusible/cortacircuito o
protector de sobrecarga del motor
2. Conéctelo, determine la causa del problema
3. Reemplácelo
4. Desconecte y reemplace la válvula de chequeo
Antes de desmantelar
la válvula de
chequeo purgue el aire del tanque
5. Deje que la unidad se enfríe y reajuste
automáticamente. Luego llévela a un área más fresca.
6. Lleve la unidad a un Centro de Servicio autorizado de
Campbell Hausfeld.
1. Chequée las conecciones, chequée con un voltimetro
2. Reemplace el motor
3. Reemplácela o repárela
Antes de desmantelar
la válvula de
chequeo purgue el aire del tanque
1. Cerciórese de que está usando el fusible adecuado,
use un fusible de acción retardada. Desconecte los
otros artefactos eléctricos del circuito o conecte el
compresor a otro circuito.
2. Reemplácela o repárela
Antes de desmantelar
la válvula de
chequeo purgue el aire del tanque
1. Chequée todas las conexiones con agua enjabonada y
apriételas
2. Apriétela
3. Desmantele la válvula de chequeo, límpiela o
reemplácela
Antes de desmantelar
la válvula de
chequeo purgue el aire del tanque
1. Reemplace las tuberías que tengan fugas o apriételas
según sea necessario
2. Reemplácelo
!
PELIGRO
!
PELIGRO
!
PELIGRO
!
PELIGRO
El compressor no
funciona
El motor hace ruido
pero no funciona o
funciona lentamente
Los fusibles se
queman/cortacircuito se
activa con frecuencia
Nunca use jamás un
cordón de extensión
con este aparato
La presión del tanque
baja cuando el
compresor se apaga
La salida de aire es
inferior a la normal/la
presión de salida es baja
Compresores Sin Aceite
Figure 4
www.chpower.com
Tool Storage
Safety Valve
Pressure
Switch
Regulator
!
PRECAUCION
Gauge of Cord
18
14
12
10
8
8
6
6
4
Extension cords for 120V/8 Amp Unit
Length of Cord (ft)
25
50
100
150
200
250
300
400
500
Summary of Contents for FP Serie
Page 2: ...meda use or es muy o o apri telas o mantelar o mantelar Serie FP matrices...
Page 10: ...er un filtre est pas errer er le e l air er le e l air S rie FP S...
Page 12: ...oyer rcle loin sible nent de ec idit ce t e FP...
Page 14: ...e FP tal n de 15A e 120 ou e res es tre volts Dans upe du le nt 4 2 4 e de...
Page 16: ...trical fety uit els FP V 5 03 able air st e Cet ire les 6 lis bell e NUEL t...
Page 18: ...r gh for essary lve lve eries wer com...
Page 20: ...f moisture ted and allow any P Series hpower com...
Page 24: ...l y l tional ies V 5 03 g d ty e y air or n sed ot O G R A M st 22 ng...