background image

Limited Warranty

 1.  DURATION: From the date of purchase by the original purchaser as follows: One Year. 
2.  WHO GIVES THIS WARRANTY (WARRANTOR): 
 

Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400

3.  WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the 

Campbell Hausfeld compressor.

4.  WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: This Campbell Hausfeld air compressor. 
5.  WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects due to material and workmanship with the exceptions 

noted below. 

6.  WHAT IS NOT COVERED UNDER THIS WARRANTY:

A.  Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM 

THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this compressor is used for commercial, industrial 
or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow 
limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

B.  ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY 

DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion 
or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

C.  Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with 

instructions provided in the owner’s manual(s) supplied with compressor.

D.  Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment.
E.  Items or service that are normally required to maintain the product, e.g. lubricants, filters and gaskets, etc.
F.  Additional items not covered under this warranty:

1.  Any component damaged in shipment or any failure caused by installing or operating unit under conditions not 

in accordance with installation and operation guidelines or damaged by contact with tools or surroundings.

2.  Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants. 
3.  Cosmetic defects that do not interfere with compressor functionality.
4.  Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments.
5. Drain 

cocks.

6.  Damage due to incorrect voltage or improper wiring.
7.  Other items not listed but considered general wear parts.
8.  Pressure switches, air governors and safety valves modified from factory settings.
9. Belts.
10. Ring wear or valve damage from inadequate filter maintenance.

7.  RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Replace, at Warrantor’s option, compressor or component 

which is defective, has malfunctioned and/or failed to conform within the duration of the specific warranty period. 

8.  RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:

A.  Provide dated proof of purchase and maintenance records.
B.  Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the 

purchaser.

C.  Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s). 

9.  WHEN WARRANTOR WILL PROVIDE REPLACEMENT UNDER THIS WARRANTY: Replacement will be scheduled according to 

the availability of replacement compressor or parts. 

This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have 
other rights which vary from State to State or country to country.

8

www.campbellhausfeld.com

Operating Instructions and Parts List

FP1995 Series

Summary of Contents for FP1995 Series

Page 1: ...THE PRODUCT TO THE RETAILER Do not operate unit if damaged during shipping handling or use Damage may result in bursting and cause injury or property damage Warning indicates a potentially hazardous...

Page 2: ...from bursting See compressor specification decal for maximum operating pressure Do not operate with pressure switch or pilot valves set higher than the maximum operating pressure 12 Never attempt to a...

Page 3: ...o resume work This compressor is equipped with an overload protector which will shut off motor if it becomes overloaded If the overload protector is actuated the motor must be allowed to cool down for...

Page 4: ...Operation BEFORE FIRST START UP BREAK IN PROCEDURE Complete this procedure before using compressor for the first time Once completed it is not necessary to repeat 1 Turn regulator knob fully clockwise...

Page 5: ...s Figure 5 OVERLOAD PROTECTOR This compressor is equipped with a thermal overload protector which will shut off motor if it becomes overloaded If overload protector shuts motor OFF frequently look for...

Page 6: ...ace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detected 1 tighten or 2 remove fitting and apply pipe tape to threads and reassemble 4...

Page 7: ...Rear shroud 1 17 Pump motor 1 18 Cooling fan 1 19 Bracket rubber pad 4 20 Motor rubber pad 3 21 Screw M3 x 15 2 22 Hex screw 4 23 Nut M5 4 24 Screw 1 25 Wire clip 1 26 Exhaust tube FP202839AV 1 27 En...

Page 8: ...intain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component damaged in shipment or any failure caused by installing or operating unit u...

Page 9: ...sures Attention indique une situation potentiellement dangereuse qui si elle n est pas vit e PEUT mener des blessures mineures ou mod r es Avis indique de l information importante qui pourrait endomma...

Page 10: ...qui ne d passe pas 862 kPa doit tre install e dans le r servoir de ce compresseur La soupape de s ret doit avoir un d bit d air et une classification de pression suffisants pour prot ger les pi ces p...

Page 11: ...position d arr t OFF puis d brancher l appareil Patienter 30 minutes avant de rebrancher l appareil et de le remettre en marche en pla ant l interrupteur sur la position ON Ce compresseur est dot d u...

Page 12: ...re termin e avant d utiliser le compresseur pour la premi re fois Ensuite il n est pas n cessaire de la refaire 1 Tourner le bouton du r gulateur compl tement vers la droite dans le sens des aiguilles...

Page 13: ...e graissage NETTOYAGE Mettre hors circuit OFF et nettoyer la poussi re et la salet du couvercle de la pompe du r servoir et des canalisations d air SECTION DE PROTECTEUR DE SURCHARGE Ce compresseur es...

Page 14: ...vec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban tuyau pour les filets et remonter 4 Fuite du r servoir 4 V rifier le r servoir pour les...

Page 15: ...34AV 1 14 Passe fil de caoutchouc N A 1 15 Couvercle avant 1 16 Couvercle arri re 1 17 Pompe moteur 1 18 Ventilateur de refroidissement 1 19 Tampon en caoutchouc du support 4 20 Tampon en caoutchouc d...

Page 16: ...mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un montage ou fonctionnement du mod le sous des cond...

Page 17: ...ue si no se evita PODR A ocasionar la muerte o lesiones graves Precauci n indica una situaci n potencialmente peligrosa que si no se evita PUEDE dar como resultado lesiones leves o moderadas Aviso ind...

Page 18: ...terior del compresor limpio sin aceite solvente o exceso de grasa DEBE instalarle una v lvula de seguridad que est dise ada para presiones m ximas de 8 62 bar en el tanque de este compresor Esta v lvu...

Page 19: ...ente en la posici n de encendido ON para continuar con el trabajo Este compresor est equipado con un protector de sobrecarga que apagar el motor si ste se sobrecarga Si se activa el protector de sobre...

Page 20: ...iento antes de usar el compresor por primera vez Una vez completado no es necesario repetirlo 1 Gire la perilla del regulador totalmente hacia la derecha para abrir el flujo de aire 2 No conecte una m...

Page 21: ...DRENAJE DEL TANQUE Apague el compresor y libere toda la presi n despu s Abra la llave de drenaje ubicada debajo del tanque para drenarle toda la humedad LUBRICACION Este compresor no requiere lubricac...

Page 22: ...xiones flojas en los accesorios tuber a etc 3 Revise todas las conexiones con una soluci n de agua y jab n Si detecta una fuga 1 ajuste o 2 retire las conexiones y aplique cinta para tuber as en las r...

Page 23: ...1 14 Ojal de goma N A 1 15 Cubierta frontal 1 16 Cubierta posterior 1 17 Bomba motor 1 18 Ventilador de enfriamiento 1 19 Apoyo de goma para soporte 4 20 Apoyo de goma para motor 3 21 Tornillo M3 x 1...

Page 24: ...tc F Art culos adicionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contraria...

Reviews: