FP2048, FP2049
3
Installation
(Continued)
Do not use a
grounding adapter with this product!
2. If repair or replacement of cord or plug
is necessary, do not connect grounding
wire to either flat blade terminal. The
wire with insulation having an external
surface that is green (with or without
yellow stripes) is the grounding wire.
Never connect
green (or green and
yellow) wire to a live terminal.
3. Check with a qualified electrician or
serviceman if grounding instructions
are not completely understood, or if in
doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.
Overheating, short
circuiting and fire
damage will result from inadequate
wiring, etc.
Operation
Definition of Terms
Regulator
- The regulator controls the
amount of air pressure released at the
hose outlet.
ASME Safety Valve
- This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Handle
- Designed to move the
compressor.
Drain Valve
- This valve is located on
the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.
Reduce tank pressure below 10 psi,
then drain moisture from tank daily to
avoid tank corrosion. Drain moisture
from tank by opening the drain valve
located underneath the tank.
!
CAUTION
!
WARNING
!
DANGER
LUBRICATION
This is an oilless product and
DOES
NOT
require lubrication to operate.
BEFORE FIRST START-UP
BREAK-IN PROCEDURE
(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to
repeat.)
1. Turn regulator knob fully clockwise
(to the right) to open air flow.
2. Turn on/off switch to OFF position.
3. Plug in power cord.
4. Turn on/off switch to ON position
and run compressor for 5 minutes.
5. Turn on/off switch to OFF position.
6. Unplug power cord.
The compressor is now ready for use.
BEFORE EACH START-UP
OPERATING PROCEDURE
1. Turn regulator knob fully
counterclockwise (to the left) to close
air flow.
2. Connect air hose to outlet of
regulator.
3. Turn on/off switch to OFF position.
4. Plug in power cord.
5. Turn on/off switch to ON position
and let compressor run until it
reaches automatic shutoff pressure.
6. Attach tire chuck or tool to end of
hose.
7. Turn regulator knob clockwise (to
the right) to desired pressure of tool
being used.
On/Off cycling of compressor
In the ON position, the compressor
pumps air into the tank. When a shut-
off (preset “cut-out”) pressure is
reached, the compressor automatically
shuts off.
22 Sp
Compresores Sin Aceite
Handle
Regulator
ON/OFF Switch
Drain Valve
Figure 2 - Unit Identification
Safety Valve
Guía de diagnóstico de averías (Continuación)
Problema
Posible(s) Causa(s)
Acción a tomar
1. Demasiada agua en el tanque
2. Humedad elevada
1. Presostato defectuoso
2. Válvula de seguridad defectuosa
1. Demasiada condensación en el
tanque
2. Conexiones flojas (accesorios, tubería,
etc.)
1. Drene el tanque, incline el tanque para eliminar la
humedad
2. Llévelo a un área menos húmeda, utilice un filtro de
aire de línea
Nota:
La condensación de agua no es una causa para
el malfuncionamiento del compresor.
1. Cambie el interruptor de presión
2. Cambie la válvula de retención con un repuesto
original
1. Drene con más frecuencia
2. Revise todas las conexiones con una solución de agua
y jabón. Si se detecta una fuga, apriete. O quite la
conexión y aplique cinta para tuberías a las rocas y
vuelva a armar.
Exceso de humedad en
el aire de descarga
El compresor funciona
en forma continua y la
válvula de seguridad se
abre cuando aumenta
la presión
Arranques y paradas
excesivas
Gauge of Cord
18
18
16
14
14
12
12
10
10
Extension cords for 120V/2.5 Amp Unit
Length of Cord (ft)
25
50
100
150
200
250
300
400
500
www.chpower.com