General Safety

caliFornia propoSition 65

 

This product or its  

  power cord may 

contain chemicals, including lead, known 
to the State of California to cause cancer 
and birth defects or other reproductive 
harm. Wash hands after handling.
 

You can 

  create 

dust when you cut, sand, 
drill or grind materials 
such as wood, paint, metal, 
concrete, cement, or other masonry. This 
dust often contains chemicals known 
to cause cancer, birth defects, or other 
reproductive harm. Wear protective gear.

General SaFetY inForMation

Air compressors are utilized in a variety 
of air system applications. Because air 
compressors and other components 
(material pump, spray gun, filters, 
lubrications, hoses, etc.) used make up 
a high pressure pumping system, the 
following safety precautions should be 
observed at all times. Only persons well 
acquainted with these rules of safe 
operation should be allowed to use the 
air compressor.

 

 

  Risk of 

Bursting! This compressor 
is designed to provide air 
pressure up to 200 psi. Most 
attachments are designed to operate 
at a maximum pressure of less than 
125 psi. DO NOT adjust the regulator to 
result in output pressure greater than 
the marked maximum pressure of the 
attachment.
 

Risk of Injury! Do not 

  direct air stream at 

body.
 

All electrical work 

  should be done 

by a qualified (licensed or certified) 
electrician. On a properly wired circuit, 
the black wires supply a voltage 
potential even when the unit is off.

 1.  Read instruction 

manuals for each 
component carefully, 
before attempting to 
assemble, disassemble  
or operate your particular system.

 2.  Wear safety glasses and 

use hearing protection 
when operating the 
pump or unit.

 3.  Do not stand on or use the pump or 

unit as a handhold.

 4.  Do not exceed pressure rating of 

any component in system.

 5.  Protect material lines and air lines 

from damage or puncture. Keep 
hose and power cable away from 
sharp objects, chemical spills, oil, 
solvents, and wet floors.

 6.  Never point a spray gun at oneself 

or any other person. Accidental 
discharge may result in serious 
injury.

 7.  Check hoses for weak or worn 

condition, before each use, making 
certain all connections are secure; 
do not use if deficiency is found. 
Notify an authorized service facility 
for examination or repair.

 

Do not run  

  unattended. Leaving 

compressor in ON position may allow it to 
turn on inadvertently. To prevent this and 
possible damage from power surge, turn 
to OFF position after each use.

 8.  Release all pressures within system 

slowly; dust and debris may be 
harmful.

 

Keep  

  fingers 

away from a running 
compressor; fast moving 
and hot parts will cause 
injury and/or burns.
 

Disconnect power  

  and depressurize 

system before servicing air compressor! 

 9.  Follow all local electrical and safety 

codes, as well as the National 
Electrical Code (NEC) and the 
Occupational Safety and Health Act 
(OSHA).

10. Wiring and fuses should follow 

electrical codes, current capacity, 
and be properly grounded.

11. Electric motors must be securely 

and adequately grounded. See 
grounding instructions and 
extension cord information, in this 
manual.

12. Always disconnect power source 

before working on or near a motor, 
or its connected load. If power 
disconnect point is out-of-sight, lock 
it in the open position and tag to 
prevent unexpected application of 
power.

13. Guard all moving parts; keep visitors 

away. Never allow children in work 
area.

14. Use only a properly grounded outlet 

that will accept a three pronged 
plug, and wear shoes to prevent 
shock hazards.

 

Be  

  careful 

when touching exterior of 
operating motor; it may be 
hot enough to cause injury. 
Compressor parts may be hot even if the 
unit is stopped.

15. Protect power cable from coming in 

contact with sharp objects.

16. Clean electrical or electronic 

equipment with an approved 
cleaning agent, such as dry, 
nonflammable cleaning solvent.

 

Motors, 

  electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a flammable gas 
or vapor. Never operate or repair the 
unit near a flammable gas or vapor. 
Never store flammable liquids or gases 
in the vicinity of the compressor.

17. To reduce fire hazard, 

keep engine/motor 
exterior free of oil, 
solvent, or grease.

18. To avoid spontaneous combustion, 

discard waste rags into approved 
metal waste cans.

19. NEVER reset safety valve or pressure 

switch. Keep safety valve free from 
paint and other accumulations. 
This provides safety against over 
pressure.

 

Never remove or  

  attempt to adjust 

safety valve. Keep safety valve free 
from paint and other accumulations.

20. Do regular maintenance; keep all 

nuts, bolts, and screws tight, to be 
sure equipment is in safe working 
condition .

21. Keep cleaning rags and other 

flammable waste materials in a 
tightly closed metal container 
and dispose of later in the proper 
fashion.

MANUAL

2

Operating Instructions

www.chpower.com

Summary of Contents for HJ3001 Series

Page 1: ...s compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suit...

Page 2: ...ay allow it to turn on inadvertently To prevent this and possible damage from power surge turn to OFF position after each use 8 Release all pressures within system slowly dust and debris may be harmfu...

Page 3: ...the spraying area as possible to minimize overspray accumulation on the compressor 5 When spraying or cleaning with solvents or toxic chemicals follow the instructions provided by the chemical manufac...

Page 4: ...essor is running indicating compressor is building pressure properly This gauge will show maximum pressure of compressor when it shuts off automatically at the pressure switch Drain Valve This valve i...

Page 5: ...hether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified technician This product is for use on a nominal 12...

Page 6: ...alve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached see Operating Proc...

Page 7: ...en compressor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution and tighten 2 Loose drain lock 2 Tighten 3 Check valve leaking 3 Disassemble check...

Page 8: ...sure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches air governors and safety valves modified...

Page 9: ...pas quip pour et ne devrait pas tre utilis comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est n cessaire d quiper le compresseur d air pompe av...

Page 10: ...out signe de faiblesse ou d usure et assurer que tous les raccordements sont s rs ne pas utiliser si endommag Contacter un centre de service autoris pour l inspection ou la r paration Ne Pas faire fon...

Page 11: ...s inflammables 3 Utiliser un respirateur pendant la pulv risation 4 Ne pas diriger la peinture ou autre mat riel pulv ris vers le compresseur Situer le compresseur aussi loin que possible de l endroit...

Page 12: ...r servoir pendant le fonctionnement du compresseur ce qui confirme que le compresseur est en train d augmenter la pression de mani re appropri e Ce manom tre indique la pression maximum du compresseu...

Page 13: ...ant vert l ext rieur avec ou sans rayures jaunes est le fil de terre Ne pas utiliser d adaptateur de mise la terre avec ce produit Ne jamais connecter le fil vert ou vert et jaune une borne lectris Co...

Page 14: ...pression de sortie d passant la pression maximale indiqu e de l accessoire Cycle marche arr t du compresseur En position ON marche le compresseur pompe de l air dans le r servoir Lorsqu il atteint un...

Page 15: ...oteur du r servoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut v rifier et nettoyer p riodiquement le filtre air dans le bo tier du filtre du c t de la t te...

Page 16: ...ibre dans la section de Installation 3 Clapet ou d chargeur d fectueux 3 Remplacer ou r parer Le protecteur de surcharge thermique se d clenche souvant 1 Tension basse 1 V rifier avec un voltm tre 2 F...

Page 17: ...17 Fr S rie HG3000 S rie HJ3001 S rie HJ3002 Notes...

Page 18: ...tallation de fils incorrecte g Autres articles pas indiqu s mais consid r s pi ces fatigue g n rales h Manostats r gulateurs d air et soupapes de s ret qui ont t s modifi s d apr s les r glages de l u...

Page 19: ...e compra con fecha para fines de la garant a Adj ntela a este manual o arch vela en lugar seguro IN634100AV 7 10 2010 Campbell Hausfeld Scott Fetzer Compresores de Aire Port tiles ASME de 13 79 bar Po...

Page 20: ...ver si est n deterioradas o hay fugas Antes de usarlo cerci rese de que las conecciones est n bien apretadas y no lo use si encuentra irregularidades Notif quele a un centro de servicio autorizado par...

Reviews: