background image

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

IN620501AV 5/10

See Warranty on page 12 for important information about commercial use of this product.

Operating Instructions and Parts Manual 

HL540200

© 2010 Campbell Hausfeld/Scott Fetzer

For parts, product & service information, 

visit 

www.chpower.com

Oil-Lubricated 

Compressors

Description

This oil-lubricated compressor is 
designed for do-it-yourselfers with a 
variety of home and automotive jobs. 
These compressors power spray guns, 
impact wrenches and other tools.  
Compressed air from this unit will 
contain moisture. Install a water filter 
or air dryer if application requires dry 
air.

Unpacking

After unpacking the unit, inspect 
carefully for any damage that may 
have occurred during transit. Make sure 
to tighten fittings, bolts, etc., before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and parts list (with 
missing parts circled) before calling.

DO nOt retUrn  
tHe PrODUCt tO  
tHe retaILer!

 

Do not operate unit  

  if damaged during 

shipping, handling or use. Damage may 
result in bursting and cause injury or 
property damage.

reaD & FOLLOW aLL InStrUCtIOnS

Save tHeSe InStrUCtIOnS

DO nOt DISCarD

 

Caution indicates  

  a potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates  

  important 

information, that if not followed,  
may cause damage to equipment.

nOte:

 Information that requires special 

attention.

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

Danger indicates  

  an imminently 

hazardous situation which, if not 
avoided, WILL result in death or  
serious injury.
 

Warning indicates  

  a potentially 

hazardous situation which, if not 
avoided, COULD result in death  
or serious injury.

Breathable Air Warning

this compressor / pump is not 
equipped and should not be 
used “as is” to supply breathing 
quality air. For any application of 
air for human consumption, the 
air compressor / pump will need 
to be fitted with suitable in-line 
safety and alarm equipment. 
this additional equipment is 
necessary to properly filter 
and purify the air to meet 
minimal specifications for Grade 
D breathing  as described in 
Compressed Gas association 
Commodity Specification  
G 7.1 - 1966, OSHa 29 CFr 1910. 
134, and / or Canadian Standards 
associations (CSa).

DISCLaIMer OF WarrantIeS
In the event the compressor is 
used for the purpose of breathing 
air application and proper in-line 
safety and alarm equipment is 
not simultaneously used, existing 
warranties shall be voided, and 
the manufacturer disclaims any 
liability whatsoever for any loss, 
personal injury or damage.

STOP!

Record the Model No., Serial No. and 
date of purchase located on the base 
below the pump in the space below.
Model No. 

HL540200

Serial No. 

____________________

Date of purchase  _________________

Retain these numbers for  

future reference.

Summary of Contents for HL540200

Page 1: ...ctions Do Not Discard Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed may ca...

Page 2: ...trols can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair in or near a flammable gas or vapor Never store flammable liquids or gases in the vicinity of the comp...

Page 3: ...amination This debris will damage the motor Electrical Installation All wiring and electrical connections should be performed by a qualified electrician Installation must be in accordance with local c...

Page 4: ...build to maximum pressure and shut off 5 With hose attached to outlet of compressor attach tire chuck or other tool to open end of hose 6 Adjust regulator to proper pressure for tool or tire Operate t...

Page 5: ...spect 3 If the filter element is dirty or clogged replace it 4 Reinstall filter and cover Important Locate unit as far from spraying area as hose will allow to prevent overspray from clogging filter E...

Page 6: ...sor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank...

Page 7: ...r 2 Clean or replace filter 3 Circuit overloaded 3 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 4 Exten...

Page 8: ...8 Operating Instructions and Parts Manual www chpower com 1 2 3 29 28 27 25 26 4 24 23 5 7 8 9 11 12 13 10 14 15 14 17 9 8 16 22 5 21 19 20 18 6 Figure 7 Repair parts illustration for model HL540200...

Page 9: ...t n 2 10 Exhaust tube n 1 11 Drain valve HL030700AV 1 12 Tank assembly 1 13 Bolt M6 x 12 k 2 14 Washer M6 l 6 15 Bolt M6 x 16 l 4 16 Base 1 17 Foot l 4 18 Plug 1 19 Pressure regulator HL030800AV 1 20...

Page 10: ...Manual www chpower com Figure 8 Repair parts illustration for HL360000AV pump motor 26 1 46 8 9 2 5 47 1 3 4 5 6 7 10 11 22 18 19 12 16 15 13 14 20 17 15 21 22 30 23 24 29 25 28 27 18 31 32 34 35 33...

Page 11: ...f Part No Description No Qty 36 Bearing 1 37 Rotor 1 38 Bearing 1 39 Stator with thermal protector 1 40 Rear end bell 1 41 Fan t 1 42 Snap ring t 1 43 Plain washer M5 k 4 44 Lock washer M5 k 4 45 Moto...

Page 12: ...lve failure caused by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limit...

Page 13: ...S CONSERVER CES INSTRUCTIONS Ne pas jeter Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher l...

Page 14: ...mmandes lectriques peuvent causer des arcs lectriques qui peuvent allumer un gaz ou une vapeur inflammable Ne jamais utiliser ou r parer le mod le pr s d un gaz ou d une vapeur inflammable Ne jamais e...

Page 15: ...es objets Ne pas situer la prise d air du compresseur pr s de la vapeur un jet pulv ris de peinture endroits de d capage au sable ou autre sources de contamination Le d bris endommagera le moteur Inst...

Page 16: ...sens antihoraire pour fermer le d bit d air 3 Tourner l interrupteur la position AUTO automatique 4 Le compresseur accumulera la pression jusqu ce qu il atteint la pression maximum et s arr tera 5 Av...

Page 17: ...5 Changer l huile apr s chaque 50 heures d usage ENTRETIEN DU FILTRE D AIR D ASPIRATION Retrait inspection et remplacement Figure 6 Il faut retirer l l ment du filtre d aspiration et le v rifier r gu...

Page 18: ...non retour avec de l air dans le r servoir purger le r servoir 4 Soupape de d charge d fectueuse sur le manostat 4 Remplacer la soupape de d charge 5 Condensateur s de moteur d fectueux 5 Remplacer l...

Page 19: ...iltre d air obstru 2 Nettoyer ou remplacer 3 Surcharge de circuit 3 V rifier le type de fusible utiliser un fusible retardement D brancher les autres appareils lectriques du circuit ou faire fonctionn...

Page 20: ...r Instructions d Utilisation et Manual de Pi ces 1 2 3 29 28 27 25 26 4 24 23 5 7 8 9 11 12 13 10 14 15 14 17 9 8 16 22 5 21 19 20 18 6 Figure 7 Illustration des pi ces de r paration pour mod le HL540...

Page 21: ...030700AV 1 12 Assemblage du r servoir 1 13 Boulon M6 x 12 k 2 14 Rondelle M6 l 6 15 Boulon M6 x 16 l 4 16 Base 1 17 Pied l 4 18 Bouchon 1 19 R gulateur de pression HL030800AV 1 20 Mamelon simple bicon...

Page 22: ...l de Pi ces 26 1 46 8 9 2 5 47 1 3 4 5 6 7 10 11 22 18 19 12 16 15 13 14 20 17 15 21 22 30 23 24 29 25 28 27 18 31 32 34 35 33 36 37 38 39 44 34 33 40 41 45 42 43 Figure 8 Illustration des pi ces de r...

Page 23: ...ription No Qty 36 Palier 1 37 Rotor 1 38 Palier 1 39 Stator avec protecteur de surcharge thermique 1 40 Ch ssis arri re du moteur 1 41 Ventilateur t 1 42 Bague d arr t t 1 43 Rondelle plate M5 k 4 44...

Page 24: ...me qui n ont pas d effet sur le fonctionnement du compresseur d Les r servoirs rouill s y compris mais sans s y limiter la rouille caus e par la vidange incorrecte ou par un environnement corrosif e L...

Page 25: ...GA TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministram...

Page 26: ...pare el compresor cerca de gases o vapores inflamables Nunca almacene l quidos o gases inflamables cerca del compresor Las piezas del compresor podr an estar calientes inclusive cuando la unidad est a...

Page 27: ...el motor Instalaci n el ctrica Todas las conexiones el ctricas y el alambrano deber n ser llevados a cabo por un electricista profesional La instalaci n debe estar conforme con los c digos locales y...

Page 28: ...onamiento 1 Coloque el interruptor en OFF y conecte el cord n al tomacorrientes 2 Gire la perilla del regulador en sentido antihorario para cerrar el flujo de aire 3 Coloque el interruptor en Auto 4 E...

Page 29: ...ruido c mbielo 4 Vuelva a instalar el filtro y la cubierta ImportantE Para prevenir que el exceso de pulverizaci n atore el filtro coloque la unidad tan lejos del rea de pulverizaci n como le permita...

Page 30: ...tanque baja cuando el compresor se apaga 1 Conexiones flojas conexiones tuber as etc 1 Revise todas las conexiones con una soluci n de agua y jab n Apriete o retire y aplique sellador o cintas para r...

Page 31: ...e de que est usando el fusible adecuado use un fusible de acci n retardada Desconecte los otros artefactos el ctricos del circuito o conecte el compresor a otro circuito 4 Uso del cable de extensi n c...

Page 32: ...anual de Instrucciones y Lista de Piezas 32 Sp 1 2 3 29 28 27 25 26 4 24 23 5 7 8 9 11 12 13 10 14 15 14 17 9 8 16 22 5 21 19 20 18 6 Figura 7 Ilustraci n de las piezas de repuesto para modelo HL54020...

Page 33: ...n 1 11 V lvula de drenaje HL030700AV 1 12 Ensamble del tanque 1 13 Perno M6 x 12 k 2 14 Arandela M6 l 6 15 Perno M6 x 16 l 4 16 Base 1 17 Pata l 4 18 Tap n 1 19 Regulador de presi n HL030800AV 1 20 Ni...

Page 34: ...as 34 Sp 26 1 46 8 9 2 5 47 1 3 4 5 6 7 10 11 22 18 19 12 16 15 13 14 20 17 15 21 22 30 23 24 29 25 28 27 18 31 32 34 35 33 36 37 38 39 44 34 33 40 41 45 42 43 Figura 8 Ilustraci n de las piezas de re...

Page 35: ...on No Qty 36 Cojinete 1 37 Rotor 1 38 Cojinete 1 39 Estator con protector de sobrecarga t rmica 1 40 Marco en campana del extremo posterior del motor 1 41 Ventilador t 1 42 Anillo a presi n t 1 43 Ara...

Page 36: ...ten el funcionamiento del compresor d Tanques oxidados incluyendo pero no limitado al xido debido al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran art cu...

Reviews: