background image

Oilless Compressors

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

Description 

Portable oilless air compressors are for 
home and workshop use. Cleaning or 
replacement of the inlet filter on all 
models and draining moisture from the 
air receivers are required maintenance. 

Safety Guidelines

This manual contains information that is 
very important to know and understand. 
This information is provided for SAFETY 
and to PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols. 

 

Danger indicates  

  an imminently 

hazardous situation which, if not avoided, 
will result in death or serious injury.
 

warning indicates  

  a potentially 

hazardous situation which, if not avoided, 
coulD result in death or serious injury.
 

caution indicates a  

  potentially 

hazardous situation which, if not avoided, 
MAY result in minor or moderate injury.
 

Notice indicates  

  important 

information, that if not followed, MAY 
cause damage to equipment.

Unpacking

When unpacking unit, inspect carefully 
for any damage that may have occurred 
during transit. 

Make sure any loose 

fittings, bolts, etc., are tightened before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and part

s list (with 

missing parts circled) before calling.

  Operating Instructions    

HM7000 and HU2000

Breathable Air warning

This compressor/pump is not 
equipped and should not be 
used “as is” to supply breathing 
quality air. For any application of 
air for human consumption, the 
air compressor/pump will need 
to be fitted with suitable in-line 
safety and alarm equipment. 
This additional equipment is 
necessary to properly filter 
and purify the air to meet 
minimal specifications for Grade 
D breathing  as described in 
Compressed Gas Association 
Commodity Specification G 7.1 
- 1966, OSHA 29 CFR 1910. 134, 
and/or Canadian Standards 
Associations (CSA).

DISCLAIMER OF WARRANTIES
In the event the compressor is 
used for the purpose of breathing 
air application and proper in-line 
safety and alarm equipment is 
not simultaneously used, existing 
warranties shall be voided, and 
Campbell Hausfeld disclaims any 
liability whatsoever for any loss, 
personal injury or damage.

General Safety

CALIFORNIA PROPOSITION 65

 

 This product or  

   its power cord may 

contain chemicals, including lead, known 
to the State of california to cause cancer 
and birth defects or other reproductive 
harm. wash hands after handling.
 

You can

  create 

dust when you cut, sand, 
drill or grind materials such 
as wood, paint, metal, 
concrete, cement, or other 
masonry. This dust often contains 
chemicals known to cause cancer, birth 
defects, or other reproductive harm. 
wear protective gear.

IN628800AV 1/09

GENERAL SAFETY INFORMATION

Air compressors are utilized in a variety 
of air system applications. Because air 
compressors and other components 
(material pump, spray gun, filters, 
lubrications, hoses, etc.) used make up 
a high pressure pumping system, the 
following safety precautions should be 
observed at all times. Only persons well 
acquainted with these rules of safe 
operation should be allowed to use the 
air compressor.

 

 All electrical work  

   should be done by a 

qualified (licensed or certified) 
electrician. on a properly wired circuit, 
the black wires supply a voltage 
potential even when the unit is off.

© 2009 Campbell Hausfeld/Scott Fetzer

For parts, product & service information

visit 

www.chpower.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

See Warranty on page 8 for important information about commercial use of this product.

Record the Model No., Serial No. and 

date of purchase located on the base 

below the pump in the space below.
Model No. 

____________________

Serial No. 

____________________

Date of purchase _________________

Retain these numbers for future 

reference.

STOP!

DO NOT RETURN  
THE PRODUCT TO  
THE RETAILER!

Summary of Contents for HM7000

Page 1: ...r to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA DIS...

Page 2: ...and controls can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair the unit near a flammable gas or vapor Never store flammable liquids or gases in the vicinity...

Page 3: ...to an outlet but if this is not possible an extension cord may be used It should be selected using the extension cord chart on page 3 as a guide 4 To avoid loss of power and overheating it is better t...

Page 4: ...es the maximum preset pressure In the Off position the compressor will not operate This switch should be in the Off position when connecting or disconnecting the power cord from the electrical outlet...

Page 5: ...compressor for any visible problems especially check air filter to be sure it is clean 2 Pull ring on safety valve and allow it to snap back to normal position Figure 6 Safety valve must be replaced...

Page 6: ...www chpower com Notes Portable Air Compressors...

Page 7: ...2 Check gauge chart under Operation for proper gauge wire and cord length 3 Replace motor 4 Replace or repair 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances from c...

Page 8: ...ited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any...

Page 9: ...pour la respiration Grade D d crit dans le Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 et ou Canadian Standards Associations CSA D N GATION DES GARANTIES Si le...

Page 10: ...de ne pas toucher l xt rieur du moteur car il peut tre assez chaud pour causer des blessures 15 Prot ger le c ble lectrique contre les objets pointus 16 Nettoyer l quipement lectrique ou lectronique...

Page 11: ...prise d air du compresseur pr s de la vapeur un jet pulv ris de peinture endroits de d capage au sable ou autre sources de contamination Le d bris endommagera le moteur R serv l utilisation r sidentie...

Page 12: ...cordon et son classement en amp res sur la plaque indicatrice Si vous avez des doutes utilisez le calibre plus lourd REMARQUE Le plus petit le num ro du calibre le plus lourd le cordon 4 Ce produit es...

Page 13: ...du r servoir en utilisant un mandrin de pneu un outil etc alors le compresseur red marrera automatiquement sa pression pr tablie de coupure Lorsqu un outil est utilis continuellement le compresseur pa...

Page 14: ...compresseur est de type sans huile et n exige pas de graissage PROTECTEUR DE SURCHARGE THERMIQUE Fermer le pressostat ou d brancher le compresseur pendant 20 minutes et le laisser refroidir L apparei...

Page 15: ...our le calibre de fil et la taille de cordon prolongateur corrects 3 Remplacer le moteur 4 Remplacer ou r parer 1 V rifier le type de fusible utiliser un fusible retardement D brancher les autres appa...

Page 16: ...est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle...

Page 17: ...G 7 1 1966 de la Asociaci n de Aire Comprimido Igualmente deber cumplir los requisitos establecidos por el Articulo 29 CFR 1910 134 de la Organizaci n norteamericana OSHA y o la Canadian Standards Ass...

Page 18: ...s aislantes para evitar electrocutamiento Tenga cuidado al tocar la parte externa del motor encendido ste podr a estar lmuy caliente y ocasionarle heridas 15 Evite que el cord n el ctrico tenga contac...

Page 19: ...de los tornillos 3 Enrosque el tornillo en el agujero hasta que quede ajustado Instalaci n Colocaci n Es de suma importancia instalar el compresor en un llugar limpio y bien ventilado donde la tempera...

Page 20: ...el rea de trabajo 1 Use s lo cordones de extensi n con 3 cables que tengan 3 terminales para conexi n a tierra y tomacorrientes con 3 orificios adecuados para conectar este producto 2 Cerci rese de qu...

Page 21: ...umedad del tanque diariamente para evitar que se oxide Drene la humedad del tanque abriendo la v lvula de drenaje que se encuentra debajo o en uno de los lados del tanque Antes de arrancarlo por prime...

Page 22: ...ie el elemento o todo el filtro Lubricacion Este compresor no requiere lubricaci n protector termico Apague el interruptor de presi n o desconecte el compresor por 20 minutos y d jelo enfriar Reinicia...

Page 23: ...cord n de extensi n adecuado vea la secci n CORDONES DE EXTENSION p gina 15 2 Est conectado Chequee el fusible cortacircuito o protector de sobrecarga del motorfuse breaker or motor overload 3 Reempl...

Page 24: ...arant a otorgada por el fabricante del motor de gasolina que se suministra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado...

Reviews: