background image

Portable Air Compressors

2

each component carefully, 
before attempting to assemble, 
disassemble or operate your 
particular system.

 2.  Wear safety glasses and use hearing 

protection when 
operating the pump or 
unit.

 3.  Do not stand on or use 

the pump or unit as a handhold.

 4.  Do not exceed pressure rating of 

any component in system.

 5.  Protect material lines and air lines 

from damage or puncture. Keep 
hose and power cable away from 
sharp objects, chemical spills, oil, 
solvents, and wet floors.

 6.  Never point a spray gun at oneself 

or any other person. Accidental 
discharge may result in serious injury.

 7.  Check hoses for weak or worn 

condition, before each use, making 
certain all connections are secure; 
do not use if deficiency is found. 
Notify an authorized service facility 
for examination or repair.

 

Do not run 

  unattended. leaving 

compressor in AuTo position may allow it 
to turn on inadvertently. To prevent this 
and possible damage from power surge, 
turn to oFF position after each use.

 8.  Release all pressures within system 

slowly; dust and debris may be 
harmful.

 

Keep 

  fingers 

away from a running 
compressor; fast moving 
and hot parts will cause 
injury and/or burns.
 

 Disconnect power  

   and depressurize 

system before servicing air compressor! 

 9.  Follow all local electrical and safety 

codes, as well as the National Electrical 
Code (NEC) and the Occupational 
Safety and Health Act (OSHA).

 10. Wiring and fuses should follow 

electrical codes, current capacity, and 
be properly grounded.

 11. Electric motors must be securely and 

adequately grounded. See grounding 
instructions and extension cord 
information, in this manual.

12. Always disconnect power source 

before working on or near a motor, or 
its connected load. If power disconnect 
point is out-of-sight, lock it in the 
open position and tag to prevent 
unexpected application of power.

13. Guard all moving parts; keep 

visitors away. Never allow children 
in work area.

14. Use only a properly grounded 

outlet that will accept a three 
pronged plug, and wear shoes to 
prevent shock hazards.

 

Be

  careful 

when touching exterior of 
operating motor; it may be 
hot enough to cause injury. 
compressor parts may be hot 
even if the unit is stopped.

15. Protect power cable from coming in 

contact with sharp objects.

16. Clean electrical or electronic 

equipment with an approved cleaning 
agent, such as dry, nonflammable 
cleaning solvent.

                               Motors, 

electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a flammable gas 
or vapor. Never operate or repair the 
unit near a flammable gas or vapor. 
Never store flammable liquids or gases 
in the vicinity of the compressor.

17. To reduce fire hazard, 

keep engine/motor 
exterior free of oil, 
solvent, or grease.

18. To avoid spontaneous combustion, 

discard waste rags into approved 
metal waste cans.

19. NEVER reset safety valve or pressure 

switch. Keep safety valve free from 
paint and other accumulations. This 
provides safety against over pressure.

 

Never remove or 

  attempt to adjust 

safety valve. Keep safety valve free 
from paint and other accumulations.

20. Do regular maintenance; keep all 

nuts, bolts, and screws tight, to be 
sure equipment is in safe working 
condition .

21. Keep cleaning rags and other 

flammable waste materials in a tightly 
closed metal container and dispose of 
later in the proper fashion.

22. Drain tanks of moisture after each 

day’s use. If unit will not be used for 
a while, it is best to leave drain cock 
open until such time as it is to be used. 
This will allow moisture to completely 
drain out and help prevent corrosion 
of inside of tank.

23. Inspect tank yearly for rust, pin holes 

or any other imperfections that could 
cause it to become unsafe. NEVER 
weld or drill holes in air tank.

 

Never attempt 

  to repair or modify 

a tank! welding, drilling or any other 
modification will weaken the tank resulting 
in damage from rupture or explosion. 
Always replace worn or damaged tanks.
 

Drain liquid from 

  tank daily.

SPRAYING PRECAUTIONS

 

Do not spray 

  flammable materials 

in vicinity of open flame or near ignition 
sources including the compressor unit.

24. Spray in a well ventilated area, to keep 

fumes from collecting and causing 
health and fire hazards.

25. Do not spray in vicinity of open flames 

or other places where a spark can 
cause ignition. Do not smoke when 
spraying paint, insecticides, or other 
flammable substances.

26. Use a respirator when spraying.
27. Do not direct paint or other sprayed 

material at the compressor. Locate 
compressor as far away from 
the spraying area as possible to 
minimize overspray accumulation 
on the compressor.

28. When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer.

29. Do not smoke when spraying paint, 

insecticides, or other flammable 
substances.

30. Use a face mask/ 

respirator when 
spraying and spray in a 
well ventilated area to 
prevent health and fire hazards.

31. Household use only.
32. To reduce the risk of electrical shock, 

do not expose to rain. Store indoors.

www.chpower.com

General Safety 

(Cont.)

 

Summary of Contents for HM7500

Page 1: ...specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA DISCLAIMER OF WARRANT...

Page 2: ...an cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair the unit near a flammable gas or vapor Never store flammable liquids or gases in the vicinity of the compress...

Page 3: ...s equipped with a 15 amp circuit breaker or a 15 amp slow blow fuse type T 3 If above conditions cannot be met or if nuisance tripping of current protection device occurs it may be necessary to operat...

Page 4: ...osition 3 Plug in power cord 4 Turn On Off switch to AUTO position and run compressor for 30 minutes 5 Turn On Off switch to OFF position 6 Unplug power cord The compressor is now ready for use Before...

Page 5: ...used under very dusty conditions or when a great deal of fog from spraying is allowed to circulate near unit Important Unit should be located as far from spraying area as hose will allow to prevent o...

Page 6: ...www chpower com Notes Portable Air Compressors...

Page 7: ...meter 2 Check gauge chart under Operation for proper gauge wire and cord length 3 Replace motor 4 Replace or repair 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances f...

Page 8: ...ited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any...

Page 9: ...la respiration Grade D d crit dans le Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 et ou Canadian Standards Associations CSA D N GATION DES GARANTIES Si le compre...

Page 10: ...pas toucher l xt rieur du moteur car il peut tre assez chaud pour causer des blessures 15 Prot ger le c ble lectrique contre les objets pointus 16 Nettoyer l quipement lectrique ou lectronique avec u...

Page 11: ...s Respecter toutes les codes locals et nationales de l lectricit REMARQUE Les mod les de 120 volts compresseur peuvent fonctionner sur un circuit de 120 volts 15 amp res sous les conditions suivants a...

Page 12: ...r servoir mais ne permet pas que l air se recule dans la pompe Poign e Con ue pour le d placement du compresseur Robinet de Purge Cette soupape est situ e sur la base du r servoir Utiliser cette soupa...

Page 13: ...ue sur la soupape de s ret et la permettre de retourner la position normale Figure 4 Si la soupape de s ret ne fonctionne pas ou s il y a une fuite d air apr s le relachement de la bague elle doit tre...

Page 14: ...14 Fr Compresseurs D Air Portatifs Notes...

Page 15: ...ent pour le calibre de fil et la taille de cordon prolongateur corrects 3 Remplacer le moteur 4 Remplacer ou r parer 1 V rifier le type de fusible utiliser un fusible retardement D brancher les autres...

Page 16: ...est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle...

Page 17: ...1 1966 de la Asociaci n de Aire Comprimido Igualmente deber cumplir los requisitos establecidos por el Articulo 29 CFR 1910 134 de la Organizaci n norteamericana OSHA y o la Canadian Standards Associ...

Page 18: ...slantes para evitar electrocutamiento Tenga cuidado al tocar la parte externa del motor encendido ste podr a estar lmuy caliente y ocasionarle heridas 15 Evite que el cord n el ctrico tenga contacto c...

Page 19: ...es de amperaje y voltaje indicados en la placa del motor y cumplir con las especificaciones m nimas 2 Use fusibles de acci n retardada tipo T o un cortacircuito Si no conecta los cables adecuadamente...

Page 20: ...esi n de aire expulsada por la manguera V lvula de seguridad ASME Esta v lvula autom ticamente libera el aire si la presi n del tanque excede el valor m ximo fijado de f brica Tuber a de descarga Esta...

Page 21: ...one hasta que alcance la presi n de apagado autom tico 6 Conecte la boquilla para inflar neum ticos u otra herramienta al extremo de la manguera 7 Gire la perilla del regulador hacia la derecha hasta...

Page 22: ...a frecuencia puede ser por lo siguiente 1 Voltaje bajo 2 El cord n de extensi n es muy corto o del calibre inadecuado 3 El filtro de aire est atascado 4 La ventilaci n es inadecuada Para poder arranca...

Page 23: ...n de extensi n adecuado vea la secci n CORDONES DE EXTENSION p gina 15 2 Est conectado Chequee el fusible cortacircuito o protector de sobrecarga del motorfuse breaker or motor overload 3 Reemplace e...

Page 24: ...a otorgada por el fabricante del motor de gasolina que se suministra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado dura...

Reviews: