background image

2

Operating Instructions

www.chpower.com

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

Danger indicates 

  an imminently 

hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.
 

Warning indicates 

  a potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates 

  a potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates 

  important 

information, that if not followed, may 
cause damage to equipment.

nOte:

 Information that requires special 

attention.

General Safety Information

CalIFOrnIa prOpOSItIOn 65

 

This product or its 

  power cord may 

contain chemicals, including lead, 
known to the State of California to 
cause cancer and birth defects or other 
reproductive harm. Wash hands after 
handling.
 

You can  

  create 

dust when you cut, sand, drill 
or grind materials such as 
wood, paint, metal, concrete, 
cement, or other masonry. This dust 
often contains chemicals known to 
cause cancer, birth defects, or other 
reproductive harm. Wear protective 
gear.

General SaFety

Since the air compressor and other 
components (material pump, spray 
guns, filters, lubricators, hoses, etc.) 
used, make up a high pressure pumping 
system, the following safety precautions 
must be observed at all times:

 

Do not run  

  unattended. Leaving 

compressor in AUTO position may allow 
it to turn on inadvertently. To prevent 
this and possible damage from power 
surge, turn to OFF position after each 
use. 

1.  Read all manuals included 

with this product carefully. 
Be thoroughly familiar 
with the controls and the 
proper use of the equipment.

 2.  Follow all local electrical and safety 

codes as well as in the United States, 
the National Electrical Codes (NEC) 
and Occupational Safety and Health 
Act (OSHA).

 3.  Only persons well acquainted with 

these rules of safe operation should 
be allowed to use the compressor.

4.  Keep visitors away and NEVER allow 

children in the work area.

5.  Wear safety glasses and 

use hearing protection 
when operating the unit.

6.  Do not stand on or use the unit as a 

handhold.

7.  Before each use, inspect compressed 

air system and electrical components 
for signs of damage, deterioration, 
weakness or leakage. Repair or 
replace defective items before using.

8.  Check all fasteners at frequent 

intervals for proper tightness.

 

Motors,  

  electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a flammable gas 
or vapor. Never operate or repair in or 
near a flammable gas or vapor. Never 
store flammable liquids or gases in the 
vicinity of the compressor.

  

 

Compressor parts may be hot 
even if the unit is stopped.

9.  Keep fingers away from a  

running compressor; fast moving 
and hot parts will cause injury and/
or burns.

10. If the equipment should start to 

vibrate abnormally, STOP the engine/
motor and check immediately for 
the cause. Vibration is generally a 
warning of trouble.

11. To reduce fire hazard, 

keep engine/motor 
exterior free of oil, 
solvent, or excessive 
grease.

 

Never remove or 

  attempt to adjust 

safety valve. Keep safety valve free 
from paint and other accumulations.
 

Never use plastic 

  (PVC) pipe for 

compressed air. Serious injury or death 
could result.
 

Never  

  attempt 

to repair or modify a tank! 
Welding, drilling or any other 
modification will weaken the 
tank resulting in damage from rupture 
or explosion. Always replace worn, 
cracked or damaged tanks.
 

Drain liquid from  

  tank daily.

12. Tanks rust from moisture build-up, 

which weakens the tank. Make sure 
to drain tank regularly and inspect 
periodically for unsafe conditions 
such as rust formation and corrosion.

13. Fast moving air will stir up dust 

and debris which may be harmful. 
Release air slowly when draining 
moisture or depressurizing the 
compressor system.

MANUAL

Summary of Contents for HU500000

Page 1: ...lease call 1 800 543 6400 for customer assistance Have the serial number model number and parts list with missing parts circled before calling Do not return the product to the retailer Do not operate...

Page 2: ...s in the United States the National Electrical Codes NEC and Occupational Safety and Health Act OSHA 3 Only persons well acquainted with these rules of safe operation should be allowed to use the comp...

Page 3: ...he items marked with an asterisk were shipped loose with the unit 1 Wheel has an offset hub Place wheel insert into center of hub With offset hub facing axle iron assemble axle bolt through washer and...

Page 4: ...om the tank daily to reduce the risk of corrosion Pressure Gauges These gauges will show air pressure in the compressor tank and at the compressor outlet Outlet Pressure Gauge Will show air pressure a...

Page 5: ...ounded in accordance with all local codes and ordinances Overheating short circuiting and fire damage will result from inadequate wiring TEST RESET Figure 6 Grounding Method Grounded Outlet Grounding...

Page 6: ...the tank Wear ANSI approved Z87 1 safety glasses 2 Drain moisture from tank by opening drain valve underneath tank Tilt tank to remove all moisture 3 Clean dust and dirt from tank air lines and pump...

Page 7: ...rried from the tank through the hose and out of the gun as droplets mixed with the spray material Important This condensation will cause water spots in a paint job especially when spraying other than...

Page 8: ...alve 3 Replace check valve Do not disassemble check valve with air pressure in tank bleed tank 4 Defective unloader valve on pressure switch 4 Replace unloader valve 5 Defective motor capacitor s 5 Re...

Page 9: ...turdy wedge object to bring tank to level position 3 Cylinder or piston is worn scored 3 Replace or repair as necessary Compressor runs continuously and safety valve opens as pressure rises 1 Defectiv...

Page 10: ...y d Electric motors check valves and pressure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches...

Page 11: ...il Avoir en main le num ro de s rie num ro de mod le et liste de pi ces avec les pi ces manquantes encercl es avant d appeler NE PAS RENVOYER LE PRODUIT AU MARCHAND Ne pas utiliser un mod le qui a t e...

Page 12: ...t OSHA 3 Seules les personnes bien familiaris es avec ces r glements d utilisation doivent tre autoris es se servir du compresseur 4 Garder les visiteurs l cart de et NE JAMAIS permettre les enfants d...

Page 13: ...1 La roue a un moyeu d centr Placer la garniture de roue au centre du moyeu Avec le moyeu d centr face au fer d essieu assembler le boulon d essieu travers la rondelle puis les trous dans la roue et...

Page 14: ...tte soupape pour purger l humidit du r servoir quotidiennement afin de r duire le risque de corrosion Manom tre s Ces manom tres indiquent la pression d air dans le r servoir du compresseur et la sort...

Page 15: ...rodage Cette proc dure doit tre termin e avant d utiliser le compresseur pour la premi re fois Ensuite il n est pas n cessaire de la refaire 1 Ouvrir le robinet de vidange au bas du r servoir 2 Mettre...

Page 16: ...et de vidange sous le r servoir Pencher le r servoir pour en retirer toute l humidit 3 Nettoyer la poussi re et la salet du r servoir des conduites d air et le couvercle de pompe tandis que le compres...

Page 17: ...en forme de gouttelettes m lang e avec le mat riel utilis Important Cette condensation peut causer des taches d eau sur votre travail de peinture surtout pendant la pulv risation de peinture qui n est...

Page 18: ...avec de l air dans le r servoir purger le r servoir 4 Soupape de d charge d fectueuse sur le manostat 4 Remplacer la soupape de d charge 5 Condensateur s de moteur d fectueux 5 Remplacer le condensat...

Page 19: ...oir la position niveau 3 Le cylindre ou le piston est us marqu 3 Remplacer ou r parer au besoin Le compresseur fonctionne continuellement et la soupape de s curit s ouvre tandis que la pression monte...

Page 20: ...nge r Dommage d la tension ou installation de fils incorrecte g Autres articles pas indiqu s mais consid r s pi ces fatigue g n rales h Manostats r gulateurs d air et soupapes de s ret qui ont t s mod...

Page 21: ...1 800 543 8622 para obtener ayuda Tenga a mano el n mero de serie el n mero del modelo y la lista de partes con las partes que faltan marcadas con un c rculo antes de llamar NE PAS RENVOYER LE PRODUIT...

Page 22: ...eguridad deben utilizar el compresor 4 Mantenga a los visitantes alejados y NUNCA permita la presencia de ni os en el rea de trabajo 5 Use anteojos de seguridad y prot jase los o dos para operar la un...

Page 23: ...de la rueda en el centro del cubo Con el cubo descentrado hacia el hierro del eje instale el perno del eje a trav s de la arandela y de los orificios de la rueda y del hierro del eje 2 Coloque la ara...

Page 24: ...resi n de aire en el tanque del compresor y a la salida del compresor Man metro de salida Indica la presi n de aire a la salida en libras por pulgada cuadrara bar psi Aseg rese de que este man mentro...

Page 25: ...e este procedimiento antes de usar el compresor por primera vez Una vez completado no es necesario repetirlo 1 Abra la v lvula de drenaje que se encuentra en la parte inferior del tanque 2 Coloque el...

Page 26: ...drenaje debajo del tanque Incline el tanque para eliminar toda la humedad 3 Limpie el polvo y la suciedad del tanque las l neas de aire y la cubierta de la bomba mientras el compresor contin a apagad...

Page 27: ...ndo o rociando arena la humedad saldr del tanque mezclada con el material que est rociando ImportantE Esta condensaci n ocasionar manchas en la pintura especialmente cuando est pintando con pinturas q...

Page 28: ...ula de retenci n desgastada 3 Cambie la v lvula de retenci n No desensamble la v lvula de retenci n con aire en el tanque purgue el tanque 4 V lvula de descarga defectuosa en el interruptor de presi n...

Page 29: ...ivel 3 El cilindro o pist n est desgastado marcado 3 Reemplace o repare seg n sea necesario El compresor funciona en forma continua y la v lvula de seguridad se abre cuando aumenta la presi n 1 Presos...

Page 30: ...s al alambrado incorrecto o conexi n a cicuitos con voltaje inadecuados para la unidad g Otros art culos no enumerados pero considerados de desgaste general h Presostatos controles de flujo de aire y...

Page 31: ...Notes Notas Operating Instructions Instructions d Utilisation Manual de Instrucciones 31 HU500000 HU502000...

Page 32: ...Operating Instructions Instructions d Utilisation Manual de Instrucciones Date Maintenance performed Repair components required Date Entretien ex cut l ments de remplacement requis Fecha Maintenimient...

Reviews: