Symptom

Possible cause(s)

corrective action

Compressor will not run

1.  Switch in OFF position

1.  Make sure compressor is plugged in and switch is ON.

2.  No electrical power at wall outlet

2.  Check circuit breaker or fuse at electrical panel.

3.  Compressor has reached automatic 

shutoff pressure

3.  Release air from tank until compressor restarts automatically.

4.  Motor overheated

4.  Allow compressor to cool for approximately 30 minutes so 

thermal overload switch will reset. Make sure compressor is 
run in a clean, well-ventilated area.

5.  Pressure switch bad

5.  Replace pressure switch.

Thermal overload 
protector cuts out 
repeatedly

1.  Low voltage

1.  Check voltage at wall outlet with voltmeter.

2.  Wrong gauge wire or length of 

extension cord

2.  Check extension cord chart for proper extension cord usage.

3.  Clogged intake filter

3.  Clean or replace filter.

4.  Lack of proper ventilation/room 

temperature too high

4.  Move compressor to well-ventilated area.

5.  Defective check valve

5.  Repair or replace.

6.  Defective unloader valve (on 

pressure switch)

6.  Repair or replace.

7.  Compressor valves failed

7.  Replace valve assembly.

 

Do not disassemble check valve with 

 air pressure in tank; bleed tank.

Tank pressure drops when 
compressor shuts off

1.  Loose drain valve

1.  Tighten.

2.  Check valve leaking

2.  Remove check valve. Clean or replace.

3.  Loose connections at fittings, 

tubing, etc.

3.  Check all connections with soap and water solution. If a leak 

is detected, (1) tighten or (2) remove fitting and apply pipe 
tape to threads and reassemble.

4.  Tank leaks

4.  Check tank for leaks with soap and water solution. If leak is 

detected, tank must be replaced with genuine replacement 
part.

 

Do not disassemble check valve with 

 air pressure in tank; bleed tank.

Compressor runs 
continuously and air 
output is lower than 
normal/low discharge 
pressure

1.  Excessive air usage, compressor too 

small

1.  Decrease usage or purchase unit with higher air delivery 

(SCFM).

2.  Clogged intake filter

2.  Clean or replace.

3.  Loose connections at fittings, 

tubing, etc.

3.  Check all connections with soap and water solution. If a leak 

is detected, (1) tighten or (2) remove fitting and apply pipe 
tape to threads and reassemble.

4.  Tank leaks

4.  Check tank for leaks with soap and water solution. If leak is 

detected, tank must be replaced with genuine replacement 
part.

5.  Broken valves 

5.  Replace compressor valves as necessary.

6.  Piston ring worn

6.  Replace piston rings.

Excessive moisture in 
discharge air

1.  Excessive water in tank

1.  Drain tank.

2.  High humidity

2.  Move to area of less humidity; use air line filter.
 

nOte:

 Water condensation is not caused by compressor 

malfunction.

Safety valve pops open

1.  Defective pressure switch

1.  Replace pressure switch.

2.  Defective safety valve

2.  Replace safety valve with genuine replacement part.

Summary of Contents for IN614207AV

Page 1: ...t information that if not followed may cause damage to equipment NOTE Information that requires special attention Safety Guidelines This manual contains information that is very important to know and...

Page 2: ...immediately for the cause Vibration is generally a warning of trouble 11 To reduce fire hazard keep engine motor exterior free of oil solvent or excessive grease An ASME code safety relief valve with...

Page 3: ...ot locate the compressor air inlet near steam paint spray sandblast areas or any other source of contamination This debris will damage the motor Grounding instructions 1 This product is for use on a n...

Page 4: ...d let compressor run until it reaches automatic shutoff pressure 6 Attach tire chuck or tool to end of hose 7 Turn regulator knob clockwise to the right to desired pressure of tool being used Operatio...

Page 5: ...ased when you pull on the ring or if it does not close automatically it MUST be replaced Drain Tank With compressor shut off and pressure released drain moisture from tank by opening drain valve under...

Page 6: ...e drain valve 1 Tighten 2 Check valve leaking 2 Remove check valve Clean or replace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detecte...

Page 7: ...Check valve includes part 29 30 FP209532AV 1 11 M4 x 0 7 x 6 screw 1 12 M6 x 1 0 x 10 screw l 4 13 Drain valve D 1403 1 14 Rubber foot tank u 3 15 Wire pressure switch to power switch FP209523AV 1 16...

Page 8: ...lubricants and adjustment E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any componen...

Page 9: ...CONSERVER CES INSTRUCTIONS Ne pas jeter Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher le...

Page 10: ...est g n ralement une indication d un probl me 11 Pour r duire le risque d incendie garder l ext rieur du moteur libre d huile de solvants et de graisse excessive Une soupape de s ret ASME avec une cl...

Page 11: ...ctrique en fournissant un fil d chappement pour le courant lectrique Ce produit est quip avec un cordon qui a un fil de terre avec une fiiche de terre La fiche doit tre branch e dans une prise de cour...

Page 12: ...le cordon d alimentation 5 Mettre l interrupteur marche arr t la position ON marche et faire fonctionner le compresseur jusqu ce qu il atteigne la pression d arr t automatique 6 Fixer le mandrin de p...

Page 13: ...ir en tirant sur l anneau ou si elle ne se ferme pas automatiquement il FAUT la remplacer Purger le r servoir Avec le compresseur hors circuit et la pression dissip e purger l humidit du r servoir en...

Page 14: ...remplacer 3 Connexions desserr es aux raccords tubes etc 3 V rifier toutes les connexions avec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du rub...

Page 15: ...29 et 30 FP209532AV 1 11 Vis M4 x 0 7 x 6 1 12 Vis M6 x 1 0 x 10 l 4 13 Robinet de purge D 1403 1 14 Pied en caoutchouc R servoir u 3 15 Fil pressostat avec interrupteur FP209523AV 1 16 Cordon d alim...

Page 16: ...ifiants filtres et joints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle...

Page 17: ...TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos...

Page 18: ...Mantenga los dedos alejados del compresor cuando est funcionando las piezas en movimiento o calientes le ocasionar an heridas y o quemaduras 10 Si el equipo comienza a vibrar excesivamente APAGUE la...

Page 19: ...e Instalaci n Colocaci n Es extremadamente importante instalar el compresor en un rea limpia seca y bien ventilada El compresor debe estar ubicado sobre una superficie firme y nivelada donde la temper...

Page 20: ...FF apagado 4 Enchufe el cable de corriente 5 Coloque el interruptor de encendido apagado en la posici n ON encendido Deje que el compresor funcione durante 30 minutos 6 Coloque el interruptor de encen...

Page 21: ...eas de aire IMPORTANTE El compresor debe colocarse lo m s lejos posible del rea de pulverizaci n seg n lo permita la Humedad en el aire comprimido La humedad que se acumula en el aire comprimido se co...

Page 22: ...naje floja 1 Ajuste 2 Fugas en la v lvula de retenci n 2 Retire la v lvula de retenci n Limpie o reemplace 3 Conexiones flojas en los accesorios tuber a etc 3 Revise todas las conexiones con una soluc...

Page 23: ...uye piezas No 29 y 30 FP209532AV 1 11 Tornillo M4x0 7x6 1 12 Tornillo M6x1 0x10 l 4 13 V lvula de drenaje D 1403 1 14 Pata de caucho Tanque u 3 15 Cable interruptor de presi n a interruptor de corrien...

Page 24: ...s etc F Art culos adicionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contra...

Reviews: