background image

2

Operating Instructions

www.chpower.com

General Safety Information

 

(Continued)

GeneRAl SAFeTy

Since the air compressor and other 
components (material pump, spray 
guns, filters, lubricators, hoses, etc .) 
used, make up a high pressure pumping 
system, the following safety precautions 
must be observed at all times:
1 .  Read all manuals included 

with this product carefully . 
Be thoroughly familiar 
with the controls and the 
proper use of the equipment .

 2 .  Follow all local electrical and safety 

codes as well as in the United States, 
the National Electrical Codes (NEC) 
and Occupational Safety and Health 
Act (OSHA) .

 3 .  Only persons well acquainted with 

these rules of safe operation should 
be allowed to use the compressor .

4 .  Keep visitors away and NEVER allow 

children in the work area .

5 .  Wear safety glasses and 

use hearing protection 
when operating the unit .

6 .  Do not stand on or use the unit as a 

handhold .

7 .  Before each use, inspect compressed 

air system and electrical components 
for signs of damage, deterioration, 
weakness or leakage . Repair or 
replace defective items before using .

8 .  Check all fasteners at frequent 

intervals for proper tightness .

 

Motors,  

  electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a flammable gas 
or vapor. Never operate or repair in or 
near a flammable gas or vapor. Never 
store flammable liquids or gases in the 
vicinity of the compressor.

 

Never  

  operate 

compressor without a 
beltguard. This unit can 
start automatically without 
warning. Personal injury or property 
damage could occur from contact with 
moving parts.

9 .  Do not wear loose clothing or 

jewelry that will get caught in the 
moving parts of the unit .

  

 

Compressor parts may be hot 
even if the unit is stopped.

10 . Keep fingers away from a  

running compressor; fast moving 
and hot parts will cause injury and/
or burns .

11 . If the equipment should start to 

vibrate abnormally, STOP the engine/
motor and check immediately for 
the cause . Vibration is generally a 
warning of trouble .

12 . To reduce fire hazard, keep engine/

motor exterior free of oil, solvent, or 
excessive grease .

 

An ASME code 

  safety relief valve 

with a setting no higher than 150 psi 
MUST be installed in the tank for this 
compressor. The ASME safety valve 
must have sufficient flow and pressure 
ratings to protect the pressurized 
components from bursting.
 

See compressor  

  specification decal 

for maximum operating pressure. 
Do not operate with pressure switch 
or pilot valves set higher than the 
maximum operating pressure.

13 . Never attempt to adjust ASME safety 

valve . Keep safety valve free from 
paint and other accumulations .

 

Never use plastic 

  (PVC) pipe for 

compressed air. Serious injury or death 
could result.

 

Never  

  attempt 

to repair or modify a tank! 
Welding, drilling or any other 
modification will weaken the 
tank resulting in damage from rupture 
or explosion. Always replace worn, 
cracked or damaged tanks.
 

Drain liquid from  

  tank daily.

14 . Tanks rust from moisture build-up, 

which weakens the tank . Make sure 
to drain tank regularly and inspect 
periodically for unsafe conditions 
such as rust formation and corrosion .

15 . Fast moving air will stir up dust 

and debris which may be harmful . 
Release air slowly when draining 
moisture or depressurizing the 
compressor system .

SPRAyInG PReCAUTIOnS

 

Do not  

  spray 

flammable materials in 
vicinity of open flame or near 
ignition sources including the 
compressor unit.

16 . Do not smoke when spraying paint, 

insecticides, or other flammable 
substances .

17 . Use a face mask / 

respirator when spraying 
and spray in a well 
ventilated area to prevent 
health and fire hazards .

18 . Do not direct paint or other sprayed 

material at the compressor . Locate 
compressor as far away from the 
spraying area as possible to minimize 
overspray accumulation on the 
compressor .

19 . When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer .

MANUAL

Summary of Contents for IN625501AV

Page 1: ...ement or other masonry This dust often contains chemicals known to cause cancer birth defects or other reproductive harm Wear protective gear Read Follow All Instructions Save These Instructions Do Not Discard Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize t...

Page 2: ...d start to vibrate abnormally STOP the engine motor and check immediately for the cause Vibration is generally a warning of trouble 12 To reduce fire hazard keep engine motor exterior free of oil solvent or excessive grease An ASME code safety relief valve with a setting no higher than 150 psi MUST be installed in the tank for this compressor The ASME safety valve must have sufficient flow and pre...

Page 3: ... on opposite side ASME Safety Valve This valve automatically releases air if the tank pressure exceeds the preset maximum Discharge tube This tube carries compressed air from the pump to the check valve This tube becomes very hot during use To avoid the risk of severe burns never touch the discharge tube To avoid the risk of severe burns never touch the discharge tube Check valve One way valve tha...

Page 4: ...The 120 volt 15 amp units can be operated on a 120 volt 15 amp circuit under the following conditions 1 No other electrical appliances or lights are connected to the same branch circuit 2 Voltage is 120 Volts 3 Circuit is equipped with a 15 amp circuit breaker or a 15 amp slow blow fuse type T For Canada use Type D 4 The length of copper wire between the outlet and circuit breaker is not longer th...

Page 5: ...d or the valve is stuck and cannot be actuated by the ring the safety valve must be replaced A large amount of fast moving air will be released if this valve is actuated with pressure in the tank 2 With motor OFF and unplugged clean debris from motor flywheel tank air lines and pump cooling fins Technical Service For information regarding the operation or repair of this product please call 1 800 5...

Page 6: ...eaking or damaged valves 5 Remove head and inspect for valve breakage misaligned valves damaged valve seats etc Replace defective parts and reassemble Install a new head gasket each time the head is removed Pump overheating causes air filter to melt 1 Insulating gasket between filter and head is missing 1 Install gasket 2 Broken valves blown gasket 2 Replace valves or install new gasket Excessive ...

Page 7: ...ce pressure switch Reset mechanism cuts out repeatedly or fuses blow repeatedly 1 Too many devices on same circuit 1 Limit the circuit to the use of only the air compressor 2 Incorrect fuse size or circuit breaker 2 Be sure that fuses or circuit breakers are rated properly 3 Malfunctioning check valve 3 Replace check valve Do not disassemble check valve with air pressure in tank 4 Pressure switch ...

Page 8: ...ity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rust due to improper drainage or corrosive environments e The following components are considered normal wear items and are not covered after the first year of ownership Electric motor check valve pressure switch regulator pressure gaug...

Page 9: ...ÉQUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dangereuse imminente qui MÈNERA à la mort ou à des blessures graves si elle n est pas évitée Avertissement indique une situation potentiellement dangereuse qui si elle n est pas évitée POURRAIT mener à la mort ou à de graves blessures Attention indique une situation potentiellement dangereuse qui si ell...

Page 10: ...mmédiatement La vibration est généralement une indication d un problème 12 Pour réduire le risque d incendie garder l extérieur du moteur libre d huile de solvants et de graisse excessive Une soupape de sûreté ASME avec une classification qui ne dépasse pas 1034 kPa doit être installée dans le réservoir de ce compresseur La soupape de sûreté ASME doit avoir un débit d air et une classification de ...

Page 11: ...on maximum réglée d avance Tuyau de Décharge Ce tuyau transporte l air comprimé de la pompe au clapet Ce tuyau devient très chaud pendant son utilisation Ne jamais toucher le tuyau de décharge afin d éviter des brûlures sévères Pour éviter le risque de brûlures graves ne jamais toucher le tuyau de décharge Clapet Une soupape à sens unique qui permet à l air d entrer le réservoir mais qui empêche q...

Page 12: ...iqué dans la Figure 5 Données Électriques L installation de fils insuffisante peut causer le surchauffage court circuit et dommage d incendie Les modèles de 120 volts 15 A peuvent fonctionner sur un circuit de 120 volts 15 A sous les conditions suivantes 1 Aucun autre appareil électrique ou lumière soit connecté au même branchement 2 Le voltage est de 120 volts 3 Le circuit est équipé d un disjonc...

Page 13: ...ulateur au sens des aiguilles d une montre pour purger l air Le compresseur se remettra en marche à la pression réglée d avance 7 Tourner le levier ou bouton du manostat à la position OFF et débrancher le cordon d alimentation Tourner le bouton du régulateur lentement dans le sens des aiguilles d une montre afin de dissiper toute la pression d air Ne pas procéder à l étape suivante jusqu à ce que ...

Page 14: ...avonneuse à tous les raccords et branchements et vérifier pour des bulles qui indiquent des fuites Serrer ou remplacer les raccords ou branchements qui ont des fuites 3 Arrivée d air limitée 3 Nettoyer la cartouche filtrante 4 Joints éclatés 4 Remplacer tous joints défectueux 5 Fuites ou dommage aux soupapes 5 Enlever la culasse et inspecter pour des soupapes cassées soupapes mal dressées sièges d...

Page 15: ...4 Panne de manostat contacts ne ferment pas 4 Réparer ou remplacer le manostat Le mécanisme de réenclenchement se déclenche à maintes reprises ou les fusibles sautent à maintes reprises 1 Trop d appareils sur le même circuit 1 Limiter l usage du circuit au compresseur d air seulement 2 Taille de fusible ou de disjoncteur incorrecte 2 Vérifier la classification des fusibles et des disjoncteurs 3 Fo...

Page 16: ...es réservoirs rouillés y compris mais sans s y limiter à la rouille causée par la vidange incorrecte ou par un environnement corrosif e Les composants suivants sont considérés comme des articles sujets à l usure normale et ne sont pas couverts après le premier an de possession Moteur électrique soupape de retenue interrupteur de pression régulateur manomètres tuyaux tubes raccords vis écrous artic...

Page 17: ...prenda Esta información se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes símbolos Peligro indica una situación inminentemente peligrosa que si no se evita dará como resultado la muerte o lesiones graves Advertencia indica una situación potencialmente peligrosa que si no se evita PODRÍA ocasionar la muerte o lesiones graves Precaución ...

Page 18: ...quéela inmediatamente para determinar el problema Generalmente la vibración se debe a una falla 12 Para reducir el peligro de incendios mantenga el exterior del compresor limpio sin aceite solvente o exceso de grasa DEBE instalarle una válvula de seguridad ASME que esté diseñada para presiones máximas de 10 34 bar en el tanque de este compresor Esta válvula debe estar diseñada para los valores máx...

Page 19: ...ijado Tubo de Descarga Este tubo transporta el aire comprimido del cabezal a la válvula de chequeo Este tubo se calienta mucho durante el uso Para evitar el riesgo de sufrir quemaduras severas nunca toque el tubo de descarga Para evitar el riesgo de sufrir severas nunca toque el tubo de descarga Válvula de Chequeo Esta válvula de un solo sentido permite la entrada de aire al tanque pero evita que ...

Page 20: ...do inadecuado podría ocasionar sobrecalentamiento cortocircuitos o incendios Las unidades de 120 voltios 15 amperios se pueden usar con circuitos de 120 voltios 15 amperios bajo las siguientes condiciones 1 No haya ningún otro artefacto eléctrico o luces conectados al mismo circuito 2 El voltaje es de 120 voltios 3 El circuito esté equipado con un cortacircuito de 15 amperios o un fusible de acció...

Page 21: ...an cantidad de aire que se encuentra en movimiento a gran velocidad 5 Gire la perilla del regulador completamente en el sentido contrario a las agujas del reloj El compresor alcanzará la presión máxima fijada y se apagará 6 Gire la perilla del regulador en el mismo sentido de las agujas del reloj para purgar el aire El compresor se encenderá al alcanzar una presión fijada 7 Gire la palanca o peril...

Page 22: ...tas defectuosas 4 Reemplace cualquier junta que pruebe estar defectuosa al inspeccionarla 5 Válvulas dañadas o con pérdidas 5 Quite el cabezal e inspecciónelo para detectar posibles roturas de la válvula válvulas desalineadas asientos de válvulas dañados etc Reemplace las piezas defectuosas y vuelva a armar Instale una nueva junta para el cabezal cada vez que éste sea quitado El sobrecalentamiento...

Page 23: ...n 4 Repare o reemplace el interruptor de presión El mecanismo de reajuste interrumpe el funcionamiento constantemente o los fusibles se funden con frecuencia 1 Demasiados aparatos en el mismo circuito 1 Use sólo el compresor de aire en el circuito 2 Tamaño incorrecto del fusible o del disyuntor 2 Asegúrese de que los fusibles o los disyuntores sean del tamaño adecuado 3 Malfuncionamiento de la vál...

Page 24: ...yendo pero no limitado al óxido debido al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran artículos sujetos a desgaste normal y no son cubiertas después del primer año de propiedad Motor eléctrico válvula de retención interruptor de presión regulador manómetros mangueras tuberías tubos accesorios y acoples tornillos tuercas artículos de ferretería corre...

Reviews: