background image

Operating Instructions and Parts List

2

www.chpower.com

MW2500 Series

General Safety Information

caLIFOrnIa PrOPOSItIOn 65

 

This product or its 

 power cord may 

contain chemicals, including lead, 
known to the State of California to 
cause cancer and birth defects or other 
reproductive harm. Wash hands after 
handling.
 

You can  

 create 

dust when you cut, sand, 
drill or grind materials 
such as wood, paint, metal, 
concrete, cement, or other masonry. 
This dust often contains chemicals 
known to cause cancer, birth defects, 
or other reproductive harm. Wear 
protective gear.

GeneraL SaFety

Since the air compressor and other 
components (material pump, spray 
guns, filters, lubricators, hoses, 
etc.) used, make up a high pressure 
pumping system, the following safety 
precautions must be observed at all 
times:
1.  Read all manuals 

included with this 
product carefully. Be 
thoroughly familiar with 
the controls and the proper use of 
the equipment.

 2.  Follow all local electrical and safety 

codes as well as in the United 
States, the National Electrical Codes 
(NEC) and Occupational Safety and 
Health Act (OSHA).

 3.  Only persons well acquainted 

with these rules of safe operation 
should be allowed to use the 
compressor.

4.  Keep visitors away and NEVER 

allow children in the work area.

5.  Wear safety glasses and 

use hearing protection 
when operating the 
unit.

6.  Do not stand on or use the unit as 

a handhold.

7.  Before each use, inspect 

compressed air system and 
electrical components for signs of 
damage, deterioration, weakness 
or leakage. Repair or replace 
defective items before using.

8.  Check all fasteners at frequent 

intervals for proper tightness.

 

Motors,  

 electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a flammable gas 
or vapor. Never operate or repair in or 
near a flammable gas or vapor. Never 
store flammable liquids or gases in the 
vicinity of the compressor.
  

 

Compressor parts may 
be hot even if the unit is 
stopped.

9.  Keep fingers away from a  

running compressor; fast moving 
and hot parts will cause injury and/
or burns.

10. If the equipment should start 

to vibrate abnormally, STOP 
the engine/motor and check 
immediately for the cause. 
Vibration is generally a warning of 
trouble.

11. To reduce fire hazard, keep engine/

motor exterior free of oil, solvent, 
or excessive grease.

 

An ASME code 

 safety relief valve 

with a setting no higher than 170 psi 
MUST be installed in the tank for this 
compressor. The ASME safety valve 
must have sufficient flow and pressure 
ratings to protect the pressurized 
components from bursting.
 

See compressor  

 specification decal 

for maximum operating pressure. 
Do not operate with pressure switch 
or pilot valves set higher than the 
maximum operating pressure.

12. Never attempt to adjust ASME 

safety valve. Keep safety valve 
free from paint and other 
accumulations.

 

Never use plastic 

 (PVC) pipe for 

compressed air. Serious injury or death 
could result.
 

Never  

 attempt 

to repair or modify a tank! 
Welding, drilling or any 
other modification will 
weaken the tank resulting in damage 
from rupture or explosion. Always 
replace worn, cracked or damaged 
tanks.
 

Drain liquid from  

 tank daily.

13. Tanks rust from moisture build-up, 

which weakens the tank. Make 
sure to drain tank regularly and 
inspect periodically for unsafe 
conditions such as rust formation 
and corrosion.

14. Fast moving air will stir up dust 

and debris which may be harmful. 
Release air slowly when draining 
moisture or depressurizing the 
compressor system.

SPrayInG PrecaUtIOnS

 

Do not  

 spray 

flammable materials in 
vicinity of open flame 
or near ignition sources 
including the compressor unit.

15. Do not smoke when spraying paint, 

insecticides, or other flammable 
substances.

16. Use a face mask / 

respirator when spraying 
and spray in a well 
ventilated area to 
prevent health and fire 
hazards.

17. Do not direct paint or other 

sprayed material at the compressor. 
Locate compressor as far away 
from the spraying area as 
possible to minimize overspray 
accumulation on the compressor.

18. When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer.

Introduction

Refer to Figure 2 to locate the 
following items.

On/Off Switch

 — This unit is 

equipped with an illuminated  
On / Off switch. In the “

On

” position 

the button will be depressed and 
the switch will light up. The switch 
will remain lit as long as the button 
is depressed and there is power to 
the unit. The pressure switch will 
automatically turn the pump / motor 
on or off based on the pressure inside 
the tank. If the unit is unplugged the 
light will not be on. In the “

OFF

” 

position the switch will not be 
depressed and the light will not be on.

MANUAL

Summary of Contents for IN634000AV

Page 1: ...manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the foll...

Page 2: ...motor exterior free of oil solvent or excessive grease An ASME code safety relief valve with a setting no higher than 170 psi MUST be installed in the tank for this compressor The ASME safety valve m...

Page 3: ...eam paint spray sandblast areas or any other source of contamination This debris will damage the motor Grounding instructions 1 This product is for use on a nominal 120 volt circuit and has a groundin...

Page 4: ...re chuck or tool to end of hose 7 Turn regulator knob clockwise to the right to desired pressure of tool being used Operation START UP Do not attach air tools to open end of the hose until start up is...

Page 5: ...t moving air from being directed toward your face 3 The safety valve should automatically close at approximately 40 psi 50 psi If the safety valve does not allow air to be released when you pull on th...

Page 6: ...s off 1 Loose connections at fittings tubing air line or tool 1 Check all connections with soap and water solution If a leak is detected 1 tighten or 2 remove fitting and apply pipe tape to threads an...

Page 7: ...7 Notes MW2500 Series www chpower com Operating Instructions and Parts List...

Page 8: ...43 6400 Please provide following information Model number Serial number if any Part description and number as shown in parts list Address any correspondence to Campbell Hausfeld Attn Customer Service...

Page 9: ...feet n 3 18 Screw n 3 19 Pressure switch WL052900AV 1 20 Manifold tube includes nut and fitting WL053000AV 1 21 Regulator includes knob cap and screw WL053100AV 1 22 Outlet gauge WL053200AV 1 23 1 4...

Page 10: ...ll 1 800 543 6400 Please provide following information Model number Serial number if any Part description and number as shown in parts list Address any correspondence to Campbell Hausfeld Attn Custome...

Page 11: ...backer 1 8 Exhaust valve 1 9 Valve plate 1 10 Intake valve 1 11 Intake valve backer 1 12 O ring SV627400AV 1 13 Cylinder 1 14 Motor assembly 1 15 Pulley 1 16 Piston bearing 1 17 Eccentric pulley 1 18...

Page 12: ...bricants and adjustment E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component...

Page 13: ...RVER CES INSTRUCTIONS Ne pas jeter Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symb...

Page 14: ...cart du compresseur les pi ces mobiles et chaudes peuvent causer des blessures et ou des br lures 10 Si l quipement vibre anormalement ARR TER le moteur et l inspecter imm diatement La vibration est...

Page 15: ...ette soupape est situ e sur la base du r servoir Utiliser cette soupape pour purger l humidit du r servoir quotidiennement afin de r duire le risque de corrosion R initialisation du moteur non visible...

Page 16: ...on ON MARCHE Laissez le compresseur tourner pendant 30 minutes 6 Mettre l interrupteur marche arr t la position OFF ARR T 7 D brancher le cordon d alimentation Le compresseur est maintenant pr t tre u...

Page 17: ...upape de s ret de la mani re suivante 1 Brancher le compresseur et le faire fonctionner jusqu ce qu il atteigne la pression d arr t voir proc dure de fonctionnement 2 Porter des lunettes de s curit ti...

Page 18: ...solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban tuyau pour les filets et remonter 2 Robinet de vidange desserr 2 Resserrer 3 V rifier toute fui...

Page 19: ...19 Fr Notes S rie MW2500...

Page 20: ...d le Code imprim sur l unit Description de la pi ce et son num ro Adresser toute correspondance Campbell Hausfeld Attn Customer Service 100 Production Drive Harrison OH 45030 Instructions d Utilisatio...

Page 21: ...3 19 Manostat WL052900AV 1 20 Tube de collecteur inclut crou et raccord WL053000AV 1 21 R gulateur inclut bouton bouchon et vis WL053100AV 1 22 Jauge de sortie WL053200AV 1 23 Coupleur industriel m le...

Page 22: ...00 S il vous pla t fournir l information suivante Num ro de mod le Code imprim sur l unit Description de la pi ce et son num ro Adresser toute correspondance Campbell Hausfeld Attn Customer Service 10...

Page 23: ...1 10 Soupape d aspiration 1 11 Appui de soupape d admission 1 12 Joint torique SV627400AV 1 13 Cylindre 1 14 Moteur quip 1 15 Poulie 1 16 Roulement de piston 1 17 Excentrique poulie 1 18 Essieu excent...

Page 24: ...ants filtres et joints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle pan...

Page 25: ...IGA TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministra...

Page 26: ...ntenga los dedos alejados del compresor cuando est funcionando las piezas en movimiento o calientes le ocasionar an heridas y o quemaduras 10 Si el equipo comienza a vibrar excesivamente APAGUE la uni...

Page 27: ...ruptor en la posici n ON para reanudar el trabajo Si se activa el protector de sobrecarga se debe dejar enfriar el motor durante aproximadamente 30 minutos antes de que se reinicie Instalaci n Colocac...

Page 28: ...sici n ON encendido Deje que el compresor funcione durante 30 minutos 6 Coloque el interruptor de encendido apagado en la posici n OFF apagado 7 Desenchufe el cable de corriente Ahora el compresor est...

Page 29: ...y libere toda la presi n despu s Abra la llave de drenaje ubicada debajo del tanque para drenarle toda la humedad Incline el tanque para drenar completamente la humedad Humedad en el aire comprimido...

Page 30: ...or 1 Conexiones flojas en los accesorios tuber a l nea de aire o herramienta 1 Revise todas las conexiones con una soluci n de agua y jab n Si detecta una fuga 1 ajuste o 2 retire las conexiones y apl...

Page 31: ...31 Sp Notas Serie MW2500...

Page 32: ...o N mero de serie de haberlo Descripci n y n mero del repuesto seg n la lista de repuestos Puede escribirnos a Campbell Hausfeld Attn Customer Service 100 Production Drive Harrison OH 45030 Operating...

Page 33: ...Tornillo n 3 19 Presostato WL052900AV 1 20 Tubo del colector incluye tuerca y accesorios WL053000AV 1 21 Regulador incluye perilla tapa y tornillo WL053100AV 1 22 Man metro de salida WL053200AV 1 23...

Page 34: ...ordenar repuestos s rvase llamar al distribuidor m s cercano a su domicilio S rvase darnos la siguiente informaci n N mero del modelo N mero de serie de haberlo Descripci n y n mero del repuesto seg...

Page 35: ...1 13 Cilindro 1 14 Ensamblaje del motor 1 15 Polea 1 16 Casquillo del pist n 1 17 Exc ntrica polea 1 18 Eje exc ntrico 1 19 Correa WL048500AV 1 20 Cojinete 2 21 Pist n 1 22 Aro del pist n 1 23 Anillo...

Page 36: ...tc F Art culos adicionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contraria...

Reviews: