background image

Never place hands or any 
other body parts in the 
fastener discharge area of 
the tool. The tool might eject a fastener 
and could result in death or serious 
personal injury.

Never carry the tool by 
the air hose or pull the 
hose to move the tool 
or a compressor. Keep hoses away from 
heat, oil and sharp edges. Replace any 
hose that is damaged, weak or worn. 
Personal injury or tool damage could 
occur.
 

Always assume the  

  tool contains 

fasteners. Respect the tool as a working 
implement; no horseplay. Always keep 
others at a safe distance from the work 
area in case of accidental discharge of 
fasteners. Do not point the tool toward 
yourself or anyone whether it contains 
fasteners or not. Accidental triggering 
of the tool could result in death or 
serious personal injury. 

Do not drive a fastener 
on top of other 
fasteners. The fastener 
could glance and cause death or a 
serious puncture wound.
 

Do not operate or allow 
anyone else to operate 
the tool if any warnings 
or warning labels are not legible. 
Warnings or warning labels are located 
on the tool magazine and body. 
 

Do not drop or  

  throw the tool. 

Dropping or throwing the tool can 
result in damage that will make the tool 
unusable or unsafe. If the tool has been 
dropped or thrown, examine the tool 
closely for bent, cracked or broken parts 
and air leaks. STOP and repair before 
using or serious injury could occur.
 

Always check that  

  the Work Contact 

Element (WCE) is operating properly. A 
fastener could accidentally be driven 
if the WCE is not working properly. 
Personal injury may occur (See 
"Checking the Work Contact Element" 
Section).
 

Avoid using the  

  tool when the 

magazine is empty. Accelerated wear on 
the tool may occur.

 

Always remain in a 

  firmly balanced 

position when using or handling the 
tool.
 

Avoid long extended  

  periods of work 

with the tool. Stop using the tool if you 
feel pain in hands or arms.

Tool UsE AND CArE

a .  

Use clamps or another practical way 
to secure and support the workpiece 
to a stable platform. 

Holding the 

work by hand or against the body is 
unstable and is able to lead to loss 
of control . 

b .  

Do not force the tool. 

Use the 

correct tool for the application . The 
correct tool will do the job better 
and safer at the rate for which the 
tool is designed . 

c .   

Do not use the tool if the switch 
does not turn the tool on or off. 

Any 

tool that cannot be controlled with 
the switch is dangerous and must be 
repaired . 

d .  

Disconnect the tool from the 
air source before making any 
adjustments, changing accessories, 
loading, unloading or storing 
the tool. 

Such preventive safety 

measures reduce the risk of starting 
the tool unintentionally . 

e .  

Store the tool when it is idle out 
of reach of children and other 
untrained persons. 

A tool is 

dangerous in the hands of untrained 
users . 

f .   

Maintain the tool with care. 

Keep 

a cutting tool sharp and clean . A 
properly maintained tool, with sharp 
cutting edges reduces the risk of 
binding and is easier to control . 

g .  

Check for misalignment or binding 
of moving parts, breakage of parts, 
and any other condition that affects 
the tool’s operation. 

If damaged, 

have the tool serviced before using . 
Many accidents are caused by poorly 
maintained tools . There is a risk of 
bursting if the tool is damaged . 

h .  

Use only accessories that are 
identified by the manufacturer for 
the specific tool model. 

Use of an 

accessory not intended for use with 
the specific tool model, increases the 
risk of injury to persons . 

i .    Selecting an appropriate tool 

actuation system, taking into 
consideration the work application 
for which the tool is used .

 

 

Never use 

  gasoline 

or other flammable liquids 
to clean the tool. Never use 
the tool in the presence of 
flammable liquids or gases. Vapors 
could ignite by a spark and cause an 
explosion which will result in death or 
serious personal injury.

Do not remove, tamper 
with, or otherwise 
cause the Work Contact 
Element (WCE) or trigger to become 
inoperable. Do not operate any tool 
which has been modified in a like 
fashion. Death or serious personal 
injury could result.

Do not touch the trigger 
unless driving fasteners. 
Never attach air line to 
tool or carry tool while touching the 
trigger. The tool could eject a fastener 
which will result in death or serious 
personal injury.

Always disconnect the 
tool from the power 
source when unattended, 
performing any maintenance or repair, 
clearing a jam, loading, unloading or 
moving the tool to a new location. 
Always reconnect the air line AFTER 
loading any fasteners. Do not load 
the tool with fasteners when either 
the trigger is depressed or the Work 
Contact Element (WCE) is engaged. 
The tool could eject a fastener causing 
death or serious personal injury.

Always fit tool with a 
fitting or hose coupling 
on or near the tool in 
such a manner that all compressed air 
in the tool is discharged at the time the 
fitting or hose coupling is disconnected. 
Do not use a check valve or any other 
fitting which allows air to remain in the 
tool. Death or serious personal injury 
could occur.

3

NB356502

www.chpower.com

important safety instructions 

(Continued) 

!

WARNING

Summary of Contents for IN715501AV

Page 1: ...that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or seriou...

Page 2: ... before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to th air supply with the switch on d Do not overreach Keep proper footing and balance at all times Proper footing and balance enables 2 Operating Instructions www chpower com Important Safety Instructions Continued better control of the tool in unexpected situations e Use safety equipment...

Page 3: ...the air source before making any adjustments changing accessories loading unloading or storing the tool Such preventive safety measures reduce the risk of starting the tool unintentionally e Store the tool when it is idle out of reach of children and other untrained persons A tool is dangerous in the hands of untrained users f Maintain the tool with care Keep a cutting tool sharp and clean A prope...

Page 4: ...of explosion and serious injury to persons Do not use any type of reactive gases including but not limited to oxygen and combustible gases as a power source Use filtered lubricated regulated compressed air only Use of a reactive gas instead of compressed air may cause the tool to explode which will cause death or serious personal injury Use only a pressure regulated compressed air source to limit ...

Page 5: ...quential Trip Tool Check the operation of the Work Contact Element WCE trip mechanism before each use The WCE must move freely without binding through its entire travel distance The WCE spring must return the WCE to its fully extended position after being depressed Do not operate the tool if the WCE trip mechanism is not operating properly Personal injury may occur 1 Disconnect the air supply from...

Page 6: ...of the nailer 3 Undo latch by pulling out and down The wire latch will disengage from the hooks on the nose 4 The door can now be rotated exposing the jammed fastener 5 Remove the jammed fastener using pliers or a screwdriver if required 6 Rotate door back into the closed position 7 Extend the wire latch and place over the hooks on the nose 8 Close the latch by pushing the latch up and in until th...

Page 7: ...ng 4 Replace spring 5 Inadequate air flow to stapler 5 Check fitting hose or compressor 6 Worn O Ring on piston or lack of lubrication 6 Replace and lubricate o rings 7 Damaged O Ring on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten screws and fittings 9 Cap gasket leaking 9 Replace gasket Nailer runs slow or has loss of power 1 Nailer not lubricated sufficiently 1 Lubricate nailer 2 Broke...

Page 8: ...t or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is void D Normal adjustments which are explained in the owner s manual s provided with the product E Items or service that are normally required to maintain the product i e o rings springs bumpers debris shie...

Page 9: ...n très importante qui est fournie pour la SÉCURITÉ et pour ÉVITER LES PROBLÈMES D ÉQUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation hasardeuse imminente qui RÉSULTERA en perte de vie ou blessures graves Avertissement indique une situation hasardeuse potentielle qui PEUT résulter en perte de vie ou blessures graves Attention indique une situation hasard...

Page 10: ...rêt off avant de brancher à l alimentation d air Ne pas transporter l outil avec le doigt sur l interrupteur ni brancher l outil à l alimentation d air avec l interrupteur en marche 10 Fr Instructions d utilisation Importantes instructions de sécurité Suite d Ne pas trop se pencher Garder bon pied et bon équilibre en tout temps Ceci permet d avoir un meilleur contrôle de l outil dans les situation...

Page 11: ...inutilisable Ne pas faire fonctionner d outil qui a été modifié de cette façon Cela pourrait mener à la mort ou à de graves blessures Ne toucher à la gâchette qu au moment de poser des attaches Ne jamais actionner la gâchette durant le transport de l outil ou durant le raccordement de celle ci au tuyau d air comprimé L éjection accidentelle d un outil peut causer des blessures graves ou mortelles ...

Page 12: ...ource d air est ajustée à la pression d air nominale ou dans la plage de pression d air nominale b Ne jamais utiliser d oxygène de dioxyde de carbone de gaz combustible ou tout gaz en bouteille comme source d air de l outil De tels gaz peuvent exploser et provoquer de graves blessures Ne pas utiliser comme source d alimentation tout type de gaz réactif y compris mais sans s y limiter de l oxygène ...

Page 13: ... en plaçant le mécanisme de déclenchement WCE contre la surface de travail et ensuite en tirant sur la gâchette La cloueuse peut aussi être actionnée en tirant sur la gâchette et ensuite en plaçant le mécanisme de déclanchement WCE contre la surface de travail La gâchette doit être relâchée afin de rajuster l outil avant d enfoncer un autre clou EMPLOI D UN OUTIL À DÉCLENCHEMENT SÉQUENTIEL Vérifie...

Page 14: ... 9 S assurer que le mouvement de la gâchette et du mécanisme de déclenchement par contact WCE peut s effectuer vers le haut ou vers le bas sans difficulté Instructions de maintenance de l utilisateur Support Technique Pour tout renseignement sur le fonctionnement ou la réparation de cet outil veuillez utiliser notre numéro d assistance 1 800 543 6400 ou pour obtenir d autres copies de ce manuel At...

Page 15: ...r et le nez 1 Joints torique endommagés 1 Remplacer les joints torique 2 Amortisseur endommagé 2 Remplacer l amortisseur Fuite d air entre le carter et le capuchon 1 Vis desserrées 1 Serrer les vis 2 Joint d étanchéité endommagé 2 Remplacer le joint d étanchéité La cloueuse saute un clou pendant l expulsion 1 Amortisseur usé 1 Remplacer l amortisseur 2 Saleté dans la pièce du nez 2 Nettoyer la rai...

Page 16: ...nner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de sûreté Si ces appareils de sûreté sont enlevés ou modifiés la garantie sera annulée D Réglages normaux qui sont expliqués dans le s manuel s d utilisation accompagnant le produit E Articles ou services qui sont exigés pour l entretien du produit Joints torique ressorts amortisseurs é...

Page 17: ...onexiones pernos etc antes de comenzar a utilizar la unidad Medidas de Seguridad Este manual contiene información que es muy importante que sepa y comprenda Esta información se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes símbolos Ésto le indica que hay una situación inmediata que LE OCASIONARIA la muerte o heridas de gravedad Ésto l...

Page 18: ...S Área de trabajo a Mantenga el área de trabajo limpia y bien iluminada Los bancos desordenados y las áreas oscuras aumentan el riesgo de choque eléctrico incendio y lesiones personales posición de apagado antes de conectar el suministro de aire No lleve la herramienta con su dedo sobre el interruptor ni conecte la herramienta al suministro de aire con el interruptor en la posición de encendido d ...

Page 19: ...plicación de trabajo para la cual se usa la herramienta Nunca limpie la herramienta con gasolina o ningún otro líquido inflamable Nunca use la herramienta en la cercanías de líquidos o gases inflamables Una chispa podría encender los vapores y ocasionar una explosión que podría ocasionarle la muerte o heridas graves No quite modifique ni haga de otro modo que el WCE elemento de contacto de trabajo...

Page 20: ...cte a un suministro de aire capaz de exceder las 200 psi Someter la herramienta a presión excesiva puede resultar en una explosión funcionamiento anormal daños a la herramienta o graves lesiones personales Use sólo aire comprimido limpio seco y regulado a la presión de funcionamiento o dentro del rango de presiones indicado en la herramienta Antes de usar la herramienta verifique siempre que el su...

Page 21: ...IA Única Se recomienda este método para la colocación precisa de puntillas Le debe instalar a la clavadora el pasador para ciclo sencillo Este sistema requiere que oprima el gatillo cada vez que vaya a clavar un clavo Para clavar el elemento de contacto debe tocar la superficie de trabajo y el operador debe oprimir el gatillo Igualmente puede oprimir el gatillo primero y después hacer el contacto ...

Page 22: ...WCE luego gire la ruedecilla hacia la izquierda en sentido antihorario Para disminuir la profundidad de penetración gire la ruedecilla hacia la derecha en sentido horario Luego suelte en elemento de contacto WCE superior en los retenes que mantienen la ruedecilla en su lugar después de cada ajuste 3 Asegúrese que el gatillo y el Elemento de Contacto de Trabajo se mueven libremente hacia arriba y h...

Page 23: ...aire entre la cubierta y la boquilla 1 Los anillos en O están dañados 1 Debe reemplazar los anillos en O 2 La defensa está dañada 2 Debe reemplazar la defensa Hay una fuga de aire entre la cubierta y la tapa 1 Los tornillos están flojos 1 Debe apretar los tornillos 2 El empaque está dañado 2 Debe reemplazar el empaque La clavadora deja de clavar un clavo 1 La defensa está desgastada 1 Debe reempla...

Page 24: ... desconexión o modificación de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garantía quedaría cancelada D Los ajustes normales explicados en el los manual es suministrado s con el producto E Artículos o servicios normalmente requeridos para el mantenimiento del producto tales como anillos en O resortes amortiguadores defensas hojas de impulsor fusibles bat...

Reviews: