Operating Instructions and Parts Manual
5. Depress the WCE against the work surface without pulling the trigger (See
Figure 16). The nailer
MUST NOT OPERATE
. Do not use the tool if it operates
without pulling the trigger. Personal injury may result.
6. Remove nailer from work surface. The WCE must return to its original down
position. Pull the trigger (See Figure 17). The nailer
MUST NOT OPERATE
. Do not
use the tool if it operates while lifted from the work surface. Personal injury may
result.
7. Pull the trigger and depress the WCE against the work surface. The nailer
MUST
OPERATE
when in bump mode. The nailer
MUST NOT OPERATE
if in sequential
mode.
8. Depress the WCE against work surface. Pull the trigger. The nailer
MUST OPERATE
.
9. Switch nailer into the other Mode as described in Operational Modes section and
repeat.
IMPORTANT: Repeat steps one through nine with tool in Safety Lockout Mode. Tool
SHOULD NOT
operate at any step. If tool does operate while in Safety Lockout Mode,
contact Campbell Hausfeld for technical support.
eleCtroNICs oN / oFF sWItCH
Located on the battery compartment is an ON/ OFF for the tool’s electronic functions,
low nail indicator LEDs, and nail placement laser.
To utilize the function, turn the battery switch to the “ON” position. To avoid unwanted
battery depletion during storage, turn the switch to the “OFF” position.
Pre-Operation (Continued)
Figure 18 - electronic oN/oFF switch
Figure 17
Work Surface
Work Surface
Figure 16
www.chpower.com
CHN70200
13