background image

7

1 .   DURATION: From the date of purchase by the original purchaser as follows: One Year . 
2 .   WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, 

Ohio, 45030, Telephone: (800) 543-6400

3 .    WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell 

Hausfeld product . 

4 .    WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld nailer, stapler, air tool, spray gun, inflator or air 

accessory supplied or manufactured by Warrantor . 

5 .    WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects in material and workmanship which occur within the 

duration of the warranty period . 

6 .    WHAT IS NOT COVERED UNDER THIS WARRANTY:

A .  Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM 

THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION . If this product is used for commercial, industrial or 
rental purposes, the warranty will apply for ninety (90) days from the date of purchase . Some States do not allow limitation on 
how long an implied warranty lasts, so the above limitations may not apply to you .

B .  ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY 

DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT . Some States do not allow the exclusion 
or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you .

C .  Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with 

instructions provided in the owner’s manual(s) supplied with product . Accident, purchaser’s abuse, neglect or failure to 
operate products in accordance with instructions shall also include the removal or alteration of any safety devices . If such 
safety devices are removed or altered, this warranty is void .

D .  Normal adjustments which are explained in the owner’s manual(s) provided with the product .
E .  Items or service that are normally required to maintain the product .

7 .   RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, products or 

components which are defective, have malfunctioned and/or failed to conform within duration of the warranty period . 

8 .   RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:

A .  Provide dated proof of purchase and maintenance records .
B .  Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options . Freight costs, if any, must be borne by the 

purchaser .

C .  Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s) . 

9 .   WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will 

be scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability of 
replacement parts .

This Limited Warranty applies in the United States, Canada and Mexico only and gives you specific legal rights . You may also have 
other rights which vary from state to state or country to country .

RP3300

www.chpower.com

Limited Warranty

Summary of Contents for IN728500AV

Page 1: ...gital Tire Inflation System Syst me de gonflement de pneus NUM RIQUE de 12 volts Sistema DIGITAL de inflado de neum ticos de 12 voltios MAKES IT EASY TO DO IT LIKE A PRO chpower com Operating Instruct...

Page 2: ...re Inflation Inflation Of Items That Require Less Than 20 psi 5 For Standard Tire Inflation Inflation Of Tires Between 20 psi and 99 psi 5 Maintenance 6 Technical Service 6 Troubleshooting Chart 6 Lim...

Page 3: ...sure 99 psi Weight 4 0 lbs Voltage 12 Volt DC Amp Draw 9 amp 0 psi 14 amp 99 psi Cord Length 10 feet Fuse 15 amp 5 mm x 20 mm 250V Automatic Shutoff Range 20 psi to 99 psi LO Setting for Manual Operat...

Page 4: ...before using the inflator or property damage and or personal injury could occur Always use a separate pressure gauge to check the actual pressure in tires and in low pressure inflatable objects Infla...

Page 5: ...metal inflation needle is inserted correctly See Figure 2 7 If more inflation is needed repeat steps 5 and 6 8 When desired pressure is reached raise universal adapter lever and remove from the tire...

Page 6: ...e s fuse for power outlet is blown 2 Replace fuse 3 Inflator s fuse for power plug is blown 3 Replace fuse see above Inflator will not start 1 Red power button not pressed 1 Press red power button 2 P...

Page 7: ...you C Any failure that results from an accident purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual s supplied with product Accident...

Page 8: ...tantes Instructions De S curit F10 Instructions Portant Sur Un Risque d Incendie Un Choc lectrique Ou Des Blessures Aux Personnes F10 Proposition 65 de Californie F10 General Safety F10 Fonctionnement...

Page 9: ...ension 12 volts c c Tirage d amp res 9 A 0 kPa 14 A 683 kPa Longueur du cordon 3 05 m Fusible 15 A 5 mm x 20 mm 250V Arr t automatique Plage 138 682 kPa 20 99 lb po R glage LO bas pour une op ration m...

Page 10: ...mettre le frein de secours et caler les roues avant d utiliser le gonfleur Sinon il y a risque de dommage mat riel et ou blessure Toujours utiliser un autre manom tre pour v rifier la pression actuel...

Page 11: ...de soupape du pneu ou que l aiguille de gonflage de m tal est ins r e correctement voir la figure 2 7 S il faut gonfler plus r p ter les tapes 5 et 6 8 En atteignant la pression voulue relevez le lev...

Page 12: ...rtie de courant est grill 2 Remplacez le fusible 3 Le fusible du gonfleur pour la fiche d alimentation est grill 3 Remplacez le fusible voir plus haut Le gonfleur ne d marre pas 1 Le bouton de courant...

Page 13: ...u exclusion pr c dente peut donc ne pas s appliquer C Toute panne r sultant d un accident d une utilisation abusive de la n gligence ou d une utilisation ne respectant pas les instructions donn es dan...

Page 14: ...portantes Instrucciones De Seguridad S16 Instrucciones En Referencia Al Peligro De Incendios Choque El ctrico O Lesiones Personales S16 Proposici n 65 de California S16 Seguridad General S16 Funcionam...

Page 15: ...A 6 83 bar Long del Cable 3 05 m Fusible 15 A 5 mm x 20 mm 250V Apagado autom tico Rango 1 39 bar 20 psi a 6 8 bar 99 psi Configuraci n LO baja para funcionamiento manual 0 a 1 31 bar 19 psi Instrucci...

Page 16: ...io de m o e trave a dire o antes de usar o inflador ou podem ocorrer danos propriedade ou ferimentos pessoais Siempre use un man metro aparte para revisar la presi n de las llantas y objetos inflamabl...

Page 17: ...neum tico o que el pincho para inflar de metal est introducido correctamente ver Figura 2 7 Si es necesario inflar m s repita los pasos 5 y 6 8 Cuando se alcance la presi n deseada eleve la palanca de...

Page 18: ...emado 2 Cambie el fusible 3 El fusible del inflador para el enchufe de corriente est quemado 3 Cambie el fusible ver arriba El inflador no enciende 1 El bot n de corriente rojo no est presionado 1 Pre...

Page 19: ...lquier falla que resulte de un accidente abuso negligencia o incumplimiento de las instrucciones de funcionamiento y uso indicadas en el los manual es que se adjunta n al producto Dichos accidentes ab...

Page 20: ...Operating Instructions u Instructions d Utilisation u Manual de Instrucciones www chpower com 20 Notes Notes Notas RP3300...

Reviews: