11 Sp

IFT232

Manuel de Instrucciones y Lista de Piezas

Para Ordenar Repuestos, Sírvase Llamar al Distribuidor
de Campbell Hausfeld más Cercano a su Domicilio

Sírvase darnos la siguiente información:

- Número del modelo
- Número de Serie o código con fecha (de haberlo)
- Descripción y número del repuesto según la lista de repuestos

Puede escribirnos a:

The Campbell Group
Attn: Parts Department
100 Production Drive
Harrison, OH  45030   U.S.A.

1

Pistola neumática

1

2

Extensión

1

3

Dispositivo de succión

1

4

Boquilla

1

5

Manguera

1

6

Colador

1

7

Sujetador

1

8

Punta de goma

1

JUEGOS DE REPUESTO DISPONIBLES 
(Cant. 1 c/u a menos que se indique lo contrario)

Dispositivo succión c/boquilla SV113201AV

Ensamble de la manguera

SV113202AV

No. de 

Número del 

Ref.

Descripción

Repuesto Ctd.

2

Operating Instructions and Parts Manual

Air Tool Set-Up

PLEASE REFER TO 

RECOMMENDED AIR

TOOL SET-UP

(IN170102AV) FOR AIR

SYSTEM HOOK-UP INSTRUCTIONS.

NOTE: Do not use lubricator, 
Part No. PA2081, as shown in the

RECOMMENDED AIR TOOL SET-UP

instruction sheet.

For proper performance and more con-
venience, use a 3/8" I.D. hose. Hoses
longer than 50 feet should have a 1/2"
I.D. 

Spray Operation

Do not misuse this 
product. Excessive

exposure to vibration, work in awk-
ward positions and repetitive work
motions can cause injury to hands and
arms. Stop using any tool if discomfort,
numbness, tingling or pain occur, and
consult a physician.

1. Connect the solution hose to the

barb fitting.

2. Connect sprayer to air supply.

3. Place material strainer end of hose

into the solution being sprayed and
clamp the hose to the edge of the
container without crushing the tub-
ing.

!

WARNING

4. Pull the trigger and allow approxi-

mately 5 seconds for the solution to
reach the spray nozzle. Release the
trigger to stop the flow.

5. Adjust the pressure regulator to

start at 20 psi and increase until
desired spray volume and atomiza-
tion is achieved, usually between 
20 - 30 psi.

Do not exceed the 
maximum operating

pressure of the sprayer (90 psi).

!

WARNING

(Extended) Blow Gun
Operation

1. (Optional) Thread the extension to

the air blow gun.

2. (Optional) Thread the rubber tip to

the end of the extension or the
blow gun.

3. Connect to the air supply.

Do not exceed the 
maximum operating

pressure of the blow gun (90 psi).

Safety glasses
must be worn dur-

ing operation.

Never aim or spray
at yourself or any-

one else or serious injury could occur.
Always wear eye protection.

4. Pull the trigger and check to make

sure the desired air flow is achieved
(adjust the pressure regulator to
achieve the desired flow).

STORAGE

The sprayer must be thoroughly flushed
and cleaned before storing. Refer to
the manufactures instructions for the
liquid being sprayed.

TECHNICAL SERVICE 

For information regarding the opera-
tion or repair of this product, please
call 1-800-543-6400. 

!

WARNING

!

WARNING

!

WARNING

IFT232

www.chpower.com

Figure 1

Figure 2

Figure 3

1

2

3

4

6

5

7

8

Reviews: