ADJUSTING THE FASTENER
PENETRATION
The tool is equipped with an adjustable
depth of drive feature. This allows the
user to determine how deep a fastener
will be driven into the work surface.
1. Adjust operating pressure so
fasteners are driven consistently. Do
not exceed 100 psi.
2. To drive the fastener shallower, turn
the wheel (C) to right to the extent
desired.
3. To sink a fastener deeper, turn
the wheel (C) to left to the extent
desired.
4. Make sure trigger and
work contact element
(WCE) move freely up
and down without
binding or sticking
after each adjustment.
ADJUSTING THE DIRECTION OF THE
EXHAUST
The tool is
equipped with an
adjustable direction
exhaust deflector.
This is intended to
allow the user to change the direction
of the exhaust. Simply twist the
deflector to any direction desired.
6
Operating Instructions
www.chpower.com
OPERATING INSTRUCTIONS
(Continued)
CLEARING A JAM FROM THE TOOL
1. Disconnect the air
supply from the tool.
2. Remove all nails from
the magazine (see
"Loading/ Unloading
The Nailer"). Failure
to do so will cause the
nails to eject from the front of the
nailer.
3. Undo latch by pulling
out and down.
The wire latch will
disengage from the
hooks on the nose.
4. The door can now be
rotated, exposing the
jammed fastener.
5. Remove the jammed
fastener, using pliers
or a screwdriver if
required.
6. Rotate door back into
the closed position.
7. Extend the wire latch
and place over the
hooks on the nose.
8. Close the latch by
pushing the latch up
and in until the latch
snaps into place.
9. Make sure the trigger
and work contact
element (WCE) move
freely up and down
without sticking or binding.
USER-MAINTENANCE
INSTRUCTIONS
TECHNICAL SERVICE
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual.
FASTENER AND REPLACEMENT
PARTS
Use only genuine
Campbell Hausfeld
18 gauge fasteners (or equivalent - see
Fastener Interchange Information).
Tool performance, safety and durability
could be reduced if improper fasteners
are used. When ordering replacement
parts or fasteners, specify by part
number.
TOOL REPAIR
Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
ASSEMBLY PROCEDURE FOR SEALS
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots. After
reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing.
STORAGE
The stapler should be stored in a cool
dry place.
(C)
Movement
Rotate
Summary of Contents for IronForce IFN328K0
Page 9: ...9 IFN328K0 www chpower com Notes...