Shank
Nails Per
Nails Per
Model #
Length
Gauge
Finish
Head
Collation
Stick Box
FB180016AV
5/8 inch
18 Gauge
Galvanized
Brad /Brown
Adhesive
100
1000
FB180025AV
1 inch
18 Gauge
Galvanized
Brad /Brown
Adhesive
100
1000
FB180030AV
1-1/4 inch
18 Gauge
Galvanized
Brad /Brown
Adhesive
100
1000
FB180040AV
1-1/2 inch
18 Gauge
Galvanized
Brad /Brown
Adhesive
100
1000
FB180050AV
2 inch
18 Gauge
Galvanized
Brad /Brown
Adhesive
100
1000
Fasteners
The following Campbell Hausfeld brad nails are available at local retail stores. For help locating any item, call customer ser-
vice at 1-800-543-6400. Campbell Hausfeld nails meet or exceed ASTM Standard F1667.
Interchange Information
Nails used in the JB004250 Brad Nailer will also work in: Bostitch T31-1, T29-30, BT-35, BT50, Duofast BB4440, Hitachi NT45A,
Paslode 2138-F40 , Porter Cable BN125, BN200, Sears 18409, 18424, and Senco SLP20, LS2, LS5.
Troubleshooting Guide
Stop using nailer immediately if any of the following problems occur. Serious personal injury
could result. Any repairs or replacements must be done by a Qualified Service Person or
Authorized Service Center.
Symptom
Possible Cause(s)
Corrective Action
Air leaking at trigger valve area
O-Rings in trigger valve housing are damaged
Replace O-Rings. Check operation of Work Contact
Element (WCE)
Air leaking between housing
Loose screws in housing
Tighten screws
and nose
Damaged O-Rings
Replace and lubricate O-rings
Damage to bumper
Replace bumper
Air leaking between housing
Loose screws
Tighten screws
and cap
Nailer skips driving nail
Worn bumper
Replace bumper
Dirt in nose piece
Clean drive channel
Dirt or damage prevent nails or pusher from
Clean and check magazine
moving freely in magazine
Damaged pusher spring
Replace spring
Inadequate air flow to nailer
Check fitting, hose or compressor
Worn O-Ring on piston etc.
Replace and lubricate O-rings
Damaged O-Ring on trigger valve
Replace and lubricate O-rings
Air leaks
Tighten screws and fittings
Cap gasket leaking
Replace gasket
Nailer runs slow or has loss of power
Nailer not lubricated sufficiently
Lubricate nailer
Broken spring in cylinder cap
Replace Spring
Exhaust port in cap is blocked
Replace any damaged internal parts
Nails are jammed in nailer
Guide on driver is worn
Replace guide
Nails are not correct size
Use only recommended nails
Nails are bent
Replace with undamaged nails
Magazine or nose screws are loose
Tighten screws
Driver is damaged
Replace driver
Nails loaded incorrectly
Review Loading/Unloading section in this manual
Air leaking at trigger valve stem
O-Rings or seals are damaged
Replace O-Rings or seals
6
Model JB004250
Operating Instructions
www.chpower.com