6
Operating Instructions
www.chpower.com
Operation
START-UP
This
compressor
pump must be fi lled
with oil before startup. See lubrication
section.
Do not attach air
tools to open end of
the hose until start-up is completed and
the unit checks OK.
Never disconnect
threaded joints with
pressure in tank!
1.
Check for proper oil level. See
Lubrication Section.
2. Open tank drain valve.
3. Turn pressure switch lever or knob
to OFF position and plug in power
cord.
4. Turn pressure switch lever or knob to
AUTO position and run unit for 30
minutes to break in the pump parts
(See Figure 10).
5. Turn regulator knob fully
counterclockwise. Compressor will
build to maximum preset pressure
and shut off.
6. Turn regulator knob clockwise to
cause air to bleed off. Compressor
will restart at preset pressure.
7. Turn pressure switch lever or knob to
OFF position and unplug powercord.
Slowly turn regulator knob clockwise
to allow all air pressure to be
released. Do not proceed to the next
step until the tank pressure reaches
zero (0).
8. Attach hose, then add chuck or
other tool to open end of hose. Plug
in powercord. Turn pressure switch
lever to AUTO position. When full
pressure is reached turn regulator
knob clockwise until desired outlet
pressure is achieved.
9. After use, turn pressure switch lever
or knob to the Off position.
10. If compressor is not used for a long
time period, bleed air from line
and use drain valve to drain water
from the tank. Then, follow the
maintenance schedule.
NOTE:
Electric models are equipped
with a pressure switch that
automatically turns the motor OFF
when the tank pressure reaches a preset
level. After air is used from the tank and
drops to a preset low level, the pressure
switch automatically turns the motor
back on.
Maintenance
Disconnect, tag and lock out
power source, then release
all pressure from the system
before attempting to install, service,
relocate or perform any maintenance.
All repairs should be performed by an
authorized service representative.
FOR EFFICIENT OPERATION:
Perform the following test to verify free
operation of the safety valve weekly
and follow maintenance schedule.
1. Pull ring on safety valve and allow
the ring to snap back to normal
position (see Figure 11). This valve
automatically releases air if the
tank pressure exceeds the preset
maximum.
Do not attempt to
tamper with this
valve. This valve should be checked
occasionally. If air leaks after the ring
has been released, or the valve is stuck
and cannot be actuated by the ring, the
safety valve must be replaced.
A large amount of
fast moving air will
be released if this valve is actuated with
pressure in the tank.
2.
With motor OFF and unplugged,
clean debris from motor, flywheel,
tank, air lines and pump cooling fins.
TECHNICAL SERVICE
For information regarding the operation
or repair of this product, please call
1-800-543-6400.
Storage
1. When not in use, hose and
compressor should be stored in a
cool dry place.
2. Tanks should be drained of moisture.
and hose should be disconnected
and hung with open ends down to
allow any moisture to drain.
3. Protect the electrical cord from
possible damage by winding the
cord loosely around the handle of
the unit or coiling the cord up.
Figure 11
A
UT
O / OFF
Figure 10
Knob
Auto/Off
Lever - Off
Lever - Auto
Summary of Contents for Portable Air Compressor