6
Operating Instructions
www.chpower.com
Operating The Tool
user to determine how deep a fastener
will be driven into the work surface .
1 . Adjust operating pressure so
fasteners are driven consistently . Do
not exceed 120 psi .
2 . For shallow penetration, turn the
wheel (C) to right to the extent
desired .
3 . For deeper penetration, turn the
wheel (C) to left to the extent
desired .
4 . Make sure trigger and
work contact element
(WCE) move freely up
and down without
binding or sticking after
each adjustment .
aDJUSTING The DIReCTION OF The
eXhaUST
The tool is
equipped
with an
adjustable
direction
exhaust deflector . This is intended to
allow the user to change the direction
of the exhaust . Simply twist the
deflector to any direction desired .
CleaRING a JaM FROM The TOOl
1 . Disconnect the air
supply from the tool .
2 . Remove
all nails
from the
magazine
(See
Loading/ Unloading The Nailer) .
Failure to do so will cause the nails
to eject from the front of the nailer
when the nose assembly is removed .
Failure to remove all
fasteners will cause the
fasteners to eject from the front of the tool.
3 . Undo latch by pulling
out and down .
The wire latch will
disengage from the
hooks on the nose .
4 . The door can now be
rotated, exposing the
jammed fastener .
5 . Remove the jammed
fastener, using pliers
or a screwdriver if
required .
6 . Rotate door back into
the closed position .
7 . Extend the wire latch
and place over the
hooks on the nose .
8 . Close the latch by
pushing the latch up
and in until the latch
snaps into place .
9 . Make sure the trigger
and work contact
element (WCE) move
freely up and down
without sticking or
binding .
(C)
Rotate
Technical Support
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual .
Fastener and Replacement
Parts
Use only genuine
Campbell Hausfeld 16
gauge fasteners (or equivalent - see Fastener
Interchange Information). Use only genuine
Campbell Hausfeld replacement parts.
Never substitute parts. Do not use modified
parts or parts which will not give equivalent
performance to the original equipment. Tool
performance, safety and durability could be
reduced. When ordering replacement parts or
fasteners, specify by part number.
Tool Repair
Only qualified personnel should repair
the tool, and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently .
assembly Procedure For Seals
When repairing a tool, the internal
parts must be cleaned and lubricated .
Parker O-lube or equivalent must be
used on all o-rings . Each o-ring must be
coated with O-lube before assembling .
A small amount of oil must be used on
all moving surfaces and pivots .
After reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing .