Raven X - Telus EV-DO Airlink Cellular Modem 

http://www.sierrawireless.com/support/support_and_downloads.a
spx?id=17,23,1,1 

2. Each provider has a specific Wizard. Please ensure you have 
downloaded the Wizard that corresponds to your provider. 

4. You will also need a working template file (.xml) to program 
the modem. This file is available by contacting a Campbell 
Scientific Canada Applications Technician at 780-454-2505 or by 
downloading it from the Campbell Scientific Website at: 

http://www.campbellsci.ca/CampbellScientific/Download.html

 

There are different templates available for different dataloggers. 
Please be sure to choose the proper one. 

5. Connect the modem to a COM port on the PC using a direct 
RS232 Connection and attach a dual band antenna to the Raven. 

6. Start the Activation Wizard. 

4

 

Activation Wizard 

 

1.

 

Click Next to continue through the Wizard. 

 

Summary of Contents for Airlink Raven X-Telus

Page 1: ...INSTRUCTION MANUAL Copyright 2008 Campbell Scientific Canada Corp Raven X Telus July 2009...

Page 2: ...glect accidents of nature or shipping damage This warranty is in lieu of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CSC is no...

Page 3: ...s 2 2 2 Base Station Requirements 3 2 3 Datalogger Site Equipment 3 3 Configuration 4 3 1 Establish Cellular Service 4 3 2 Program the Modem 4 4 Activation Wizard 5 5 Set Up Modem using Ace Manager 10...

Page 4: ...mbedded TCP IP stack which enables transmission of serial data from non IP devices ALEOS enables several functions including remote configuration and diagnostics packet assembly and disassembly PAD fo...

Page 5: ...modem is configured using the Telus Setup Wizard and Ace Manager prior to installation The setup wizard and Ace Manager can be downloaded from www Airlink com Datalogger CR510 CR10 X CR23X CR7 CR1000...

Page 6: ...ply see power considerations Environmental Enclosure ENC 10 12 ENC 12 14 or ENC 16 18 3 Configuration 3 1 Establish Cellular Service Prior to contacting the cellular service provider have the followin...

Page 7: ...ble by contacting a Campbell Scientific Canada Applications Technician at 780 454 2505 or by downloading it from the Campbell Scientific Website at http www campbellsci ca CampbellScientific Download...

Page 8: ...gs check box is selected Now click Next The setup wizard will now attempt to establish a connection with the modem 3 Please verify that the Proper modem is displayed and that the ESN number is correct...

Page 9: ...click Next NOTE The Activate modem OTASP can be used to automatically pull down the needed information from the network This is however not recommended as it will not pull down the 1X network setting...

Page 10: ...is code in the Activation Code Text Box If the Lock Code only has 5 digits put a 0 in front of the number to make it 6 digits as the lock code must always be 6 digits Once completed click Next 7 Enter...

Page 11: ...ft If you have made an error click Back until you have reached the setting that requires changing and proceed as before After verifying everything is correct click Next It will take a few seconds for...

Page 12: ...em is now ready for advanced programming using AceManager These following steps need to be completed fairly quickly as the modem is on a dynamic IP network and the IP address can change at any time 5...

Page 13: ...ic Canada Applications Technician at 780 454 2505 Use the Load option to select the template to load into the modem 5 The new file parameters will appear in the New Value boxes as shown above 6 Click...

Page 14: ...power back on and the modem will register itself on the network within 2 minutes To confirm this make sure that the Network and Service light is solid If the Network light is flashing the modem has no...

Page 15: ...ound in the Common tab settings of the Raven modem see below c Change the maximum baud rate to one supported by the datalogger in this case for the CR1000 it is 115200 d Extra response time should be...

Page 16: ...dem Cable to the Raven X Telus modem and the other to the datalogger s RS232 port 3 If connecting to any datalogger s CS I O port you will require an SC932A interface from Campbell Scientific Connect...

Page 17: ...eed to change any settings for the two to function together Once the Crossover cable is connected to the NL115 the Raven X Telus will send its current public IP address to the NL115 for it to use If t...

Page 18: ...EV DO Airlink Cellular Modem 7 Use the drop down list for the New Value of Use Public IP Change this value to Use Private IP Enter the Host Private IP as 192 168 13 12 Enter the Modem Local IP as 192...

Page 19: ...nge the DPORT to 3000 This makes sure that any information sent to the modem from Loggernet on port 6785 will get passed through the Ethernet port and not trapped by the modem 9 Following the settings...