background image

INSTRUCTION MANUAL

AM-ENCT

Analog Multiplexer Enclosure

Revision: 12/91

C o p y r i g h t   ( c )   1 9 8 9 - 1 9 9 1

C a m p b e l l   S c i e n t i f i c ,   I n c .

Summary of Contents for AM-ENCT

Page 1: ...INSTRUCTION MANUAL AM ENCT Analog Multiplexer Enclosure Revision 12 91 C o p y r i g h t c 1 9 8 9 1 9 9 1 C a m p b e l l S c i e n t i f i c I n c ...

Page 2: ... all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc d...

Page 3: ... is ordered with an AM416 or AM32 multiplexer the multiplexer is mounted in the AM ENCT at the factory If the AM ENCT and multiplexer are ordered separately some user assembly is required The AM ENCT protects the multiplexer from windblown dust rain and sleet The AM ENCT s insulation and internal aluminum plates reduce temperature gradients across the multiplexer terminal strips Smaller thermal gr...

Page 4: ... dry surface 3 Remove and dispose the four rubber feet from the back panel of the AM416 4 Open the AM ENCT enclosure and remove the cover plate and foam insulation Figure 1 The multiplexer mounts to the backplate labeled 1A in Figure 1 5 Align the two holes through the back panel of the multiplexer with the holes on the mounting plate Attach the back plate of the AM416 to the mounting plate with t...

Page 5: ... recommended Desiccant should be used inside the AM ENCT to help reduce water vapor Desiccant should be replaced regularly Desiccant life is prolonged by plugging the cable entry port with electrician s putty or foam NOTE Because lead acid batteries may emit explosive hydrogen gas DO NOT seal an enclosure containing lead acid batteries Aluminum Plate A Figure 1 provides a framework for thermocoupl...

Page 6: ...AM ENCT ANALOG MULTIPLEXER ENCLOSURE 4 FIGURE 2 Thermocouple Lead Wire Routing ...

Page 7: ...This is a blank page ...

Page 8: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...