August 5, 2013
Specifications
Shield Material: UV stabilized polyethylene
Power Cable Diameter: 0.5 cm (0.2 in)
Signal Cable Diameter: 0.3 cm (0.1 in)
Weight: 0.86 kg (1.9 lb)
Thermocouple
Type: Chromel-Constantan
Diameter: 0.0762 mm (0.003 in)
Typical Output: 60 μV/°C
Accuracy:
Refer to the Thermocouple Measurement section
in your datalogger manual
Fan
Air Velocity at Thermocouple: 5.5 m at 12 Vdc
Life Expectancy: 65,000 hr at 30°C
Current Drain: 260 mA at 12 Vdc
Operating Voltage Range: 9 to 13 Vdc
Operating Temperature Range: -10° to 70°C
Reverse Polarity Protected
Ordering Information
Aspirated Thermocouple
ASPTC
Aspirated Thermocouple with Radiation Shield.. Must specify
signal and power cable lengths (see below).
Cable Lengths
-L
After the -L, enter the signal cable length in feet. A 15-ft
length is typically used.
-LP
After the -LP, enter the power cable length in feet. A 15-ft
length is typically used.
Mounts
UT018 -5
Tower Mounting Bracket with 5-ft Crossarm
Mounting
The ASPTC can be mounted to a tripod or tower via the UT018-5
crossarm or a user-supplied crossarm that has a square cross sec-
tion of 3.8 cm by 3.8 cm (1.5 inch by 1.5 inch).
Power Considerations
The ASPTC is typically powered with a user-supplied deep cycle
battery that is recharged with an SP20R, SP50, or SP90 solar panel;
for high current drain systems two SP90 solar panels may be used
to provide 180 W of power. The datalogger’s rechargeable bat-
tery can only be used if it is connected to ac power. For help on
analyzing your system’s power requirements, refer to our Power
Supply brochure or application note.
thermocouple
4.6 cm (1.8 in) O.D.
5.8 cm (2.3 in) O.D.
mounting bracket
power cable
signal cable
53.3 cm (21 in)
14.7 cm
(5.8 in)
↑
↓
↓
↕
←
→
↓