Section 2. Station Installation
2-4
FIGURE 2.2-2. TCAV Spatial Averaging Thermocouple Probe
2.3 Wiring
Table 2.3-1 lists the connections to the CR23X for the standard Bowen ratio
sensors measured by the example program. Because the air temperature
measurements are so critical, the air temperature thermocouples are connected
to differential channel 4 (the channel that is closest to the reference
temperature thermistor). The input terminal strip cover for the CR23X must be
installed once all connections have been made and verified (Section 13.4 of
CR23X manual).
TABLE 2.3-1. CR23X/Sensor Connections for Example
Program
CHANNEL SENSOR
COLOR
1H Q7.1
RED
1L Q7.1
BLACK
SHIELD CLEAR
2H HYGROMETER
PRT
GREEN
2L HYGROMETER
PRT
WHITE
HYGROMETER PRT
BLACK
3H TCAV
PURPLE
3L TCAV
RED
TCAV CLEAR
4H
UPPER 0.003 TC - CHROMEL
PURPLE
4L
LOWER 0.003 TC - CHROMEL
PURPLE
40 GAUGE CHROMEL
CONSTANTAN
STAINLESS STEEL
TUBE
HI
(PURPLE)
LO
(RED)
24 GAUGE
CHROMEL
CONSTANTAN