Section 7. Camera Operation Using Web Browser Interface
7-12
7.3.2 Automatic Date and Time Update
The Automatic Date and Time sub menu (see FIGURE 7-11) configures the
camera for automatic date and time updates. The setting parameters are as
follows:
•
Time Variance in Seconds to Perform clock update
Select the minimum allowable variance that will result in the camera’s
time being changed.
•
Source
Select one of 3 options for the Automatic Time updates. The possibilities
are:
o
None
The camera’s clock is highly accurate and its drift is normally less
than 2 minutes per year.
o
PakBus Port
Normally this is a datalogger. The actual time update occurs only
when a file transfer occurs to the datalogger from the camera
o
SNTP Server.
The camera will use the SNTP Time server that is specified under
Network settings (see SNTP (TIME) Server Setting). A proper
Network connection is required as well.
FIGURE 7-12. Automatic Date and Time Update
7.3.3 Site Name
The Site Name sub menu (see FIGURE 7-13) allows a site name to be used for
the web page headings. By default the Site Name is set to Campbell Scientific.
This is useful in providing an easy way of confirming the camera that you are
connected to in the web interface. The Site Name is limited to 32 characters.
Refer to FIGURE 7-14 for the location of the Site Name on the web pages.
Summary of Contents for CC5MPX 6HULHV
Page 2: ......
Page 10: ...CC5MPX Table of Contents vi ...
Page 12: ...Section 1 Introduction 1 2 ...
Page 22: ...Section 3 Getting Started 3 8 FIGURE 3 7 CC5MPX Device Configuration Utility Settings Editor ...
Page 28: ...Section 4 Cables Wiring 4 6 ...
Page 36: ...Section 6 Camera Configuration 6 2 ...
Page 72: ...Section 7 Camera Operation Using Web Browser Interface 7 36 FIGURE 7 31 Motion Detection Page ...
Page 84: ...Section 10 RS 485 Communications 10 2 ...
Page 86: ...Section 11 PakBus Communications 11 2 ...
Page 88: ...Section 12 Device Configuration Utility 12 2 FIGURE 12 2 Device Configuration Utility Screen ...
Page 90: ...Section 13 Image Quality 13 2 ...
Page 98: ...Section 15 Power Calculations and Timings 15 4 ...
Page 104: ...Section 17 Remote Image Retrieval 17 4 ...
Page 110: ...Section 19 Maintenance 19 4 FIGURE 19 5 Desiccant Location Location of Desiccant ...
Page 116: ...Section 21 System Limitations 21 2 ...
Page 122: ...Section 23 Quick Notes 23 4 ...
Page 129: ......