8-1
Section 8. Internal Jumpers
There are two sets of jumpers that are internal to the camera. One set of
jumpers is used to select either RS-232 or RS-485 communications on the
Power I/O cable. The other jumper set is used to select a pull up or a pull
down resistor on the External Trigger input line.
Refer to Section 20 Backplate Removal Procedures for details to remove the
backplate to access the internal jumpers of the camera.
8.1 RS-232 / RS-485 Jumpers
The jumper locations are shown in FIGURE 8-1. There are three jumpers that
can be moved from either the left or the right 2x3 jumper posts. When the
jumpers are on the right 2x3 jumper posts then the RS-232 output is selected
(Factory Default position). To change the serial output format from RS-232 to
RS-485 move all three jumpers from the right to the 2x3 jumper posts located
in the left position. Always move all three jumpers and never install additional
jumpers.
The available communication interfaces can be configured with the cameras
web interface or via the Device Configuration Utility. The RS-232 and RS-485
interfaces can be configured to a range of baud rates between 9600 and 115200
bps. Both interfaces support only the PakBus protocol.
FIGURE 8-1. Internal Jumper Locations
Summary of Contents for CC5MPX 6HULHV
Page 2: ......
Page 10: ...CC5MPX Table of Contents vi ...
Page 12: ...Section 1 Introduction 1 2 ...
Page 22: ...Section 3 Getting Started 3 8 FIGURE 3 7 CC5MPX Device Configuration Utility Settings Editor ...
Page 28: ...Section 4 Cables Wiring 4 6 ...
Page 36: ...Section 6 Camera Configuration 6 2 ...
Page 72: ...Section 7 Camera Operation Using Web Browser Interface 7 36 FIGURE 7 31 Motion Detection Page ...
Page 84: ...Section 10 RS 485 Communications 10 2 ...
Page 86: ...Section 11 PakBus Communications 11 2 ...
Page 88: ...Section 12 Device Configuration Utility 12 2 FIGURE 12 2 Device Configuration Utility Screen ...
Page 90: ...Section 13 Image Quality 13 2 ...
Page 98: ...Section 15 Power Calculations and Timings 15 4 ...
Page 104: ...Section 17 Remote Image Retrieval 17 4 ...
Page 110: ...Section 19 Maintenance 19 4 FIGURE 19 5 Desiccant Location Location of Desiccant ...
Page 116: ...Section 21 System Limitations 21 2 ...
Page 122: ...Section 23 Quick Notes 23 4 ...
Page 129: ......