Section 15. Power Calculations and Timings
15-3
•
Determine the power consumed by the quiescent state in Amp-hours.
Quiescent Power = quiescent minutes * quiescent current draw/60
Quiescent Power = 1418 minutes*6 mA/60 = 141.8 mA-hour or
0.1418
Amp-hours/day
•
Determine the power consumed by the active state in Amp-hours.
Active Power = active minutes * active current draw/60
Active Power = 22 minutes*250 mA/60 = 91.67 mA-hour or
0.0917 Amp-
hours/day
•
Total power consumption is the sum of the active and quiescent power.
Total Power = quiescent power +
active power
Total Power = 0.1418 Amp-hours/day + 0.0917 Amp-hours/day
Total Power = 0.2335 Amp-hours/day
Summary of Contents for CC5MPX 6HULHV
Page 2: ......
Page 10: ...CC5MPX Table of Contents vi ...
Page 12: ...Section 1 Introduction 1 2 ...
Page 22: ...Section 3 Getting Started 3 8 FIGURE 3 7 CC5MPX Device Configuration Utility Settings Editor ...
Page 28: ...Section 4 Cables Wiring 4 6 ...
Page 36: ...Section 6 Camera Configuration 6 2 ...
Page 72: ...Section 7 Camera Operation Using Web Browser Interface 7 36 FIGURE 7 31 Motion Detection Page ...
Page 84: ...Section 10 RS 485 Communications 10 2 ...
Page 86: ...Section 11 PakBus Communications 11 2 ...
Page 88: ...Section 12 Device Configuration Utility 12 2 FIGURE 12 2 Device Configuration Utility Screen ...
Page 90: ...Section 13 Image Quality 13 2 ...
Page 98: ...Section 15 Power Calculations and Timings 15 4 ...
Page 104: ...Section 17 Remote Image Retrieval 17 4 ...
Page 110: ...Section 19 Maintenance 19 4 FIGURE 19 5 Desiccant Location Location of Desiccant ...
Page 116: ...Section 21 System Limitations 21 2 ...
Page 122: ...Section 23 Quick Notes 23 4 ...
Page 129: ......