Section 7. Installation
7.9.21.6 Telnet
Telnet is used to access the same commands that are available through the support
software
terminal emulator
(p. 530).
Start a
Telnet
session by opening a DOS
command prompt and type in:
Telnet xxx.xxx.xxx.xxx <Enter>
where xxx.xxx.xxx.xxx is the IP address of the network device connected to the
CR1000.
7.9.21.7 SNMP
Simple Network Management Protocol (SNMP) is a part of the IP suite used by
NTCIP and RWIS for monitoring road conditions. The CR1000 supports SNMP
when a network device is attached.
7.9.21.8 Ping (IP)
Ping can be used to verify that the IP address for the network device connected to
the CR1000 is reachable. To use the Ping tool, open a command prompt on a
computer connected to the network and type in:
ping xxx.xxx.xxx.xxx <Enter>
where xxx.xxx.xxx.xxx is the IP address of the network device connected to the
CR1000.
7.9.21.9 Micro-Serial Server
The CR1000 can be configured to allow serial communication over a TCP/IP port.
This is useful when communicating with a serial sensor over Ethernet with micro-
serial server (third-party serial to Ethernet interface) to which the serial sensor is
connected. See the network-link manual and the
CRBasic Editor Help
for the
TCPOpen()
instruction for more information. Information on available network
links is available in the appendix
Network Links
(p. 652).
7.9.21.10
Modbus TCP/IP
The CR1000 can perform Modbus communication over TCP/IP using the Modbus
TCP/IP interface. To set up Modbus TCP/IP, specify port 502 as the
ComPort
in
the
ModBusMaster()
and
ModBusSlave()
instructions. See the
CRBasic Editor
Help
for more information. See
Modbus
(p. 411).
7.9.21.11
DHCP
When connected to a server with a list of IP addresses available for assignment,
the CR1000 will automatically request and obtain an IP address through the
Dynamic Host Configuration Protocol (DHCP). Once the address is assigned, use
DevConfig
,
PakBusGraph
,
Connect
, or the CR1000KD Keyboard Display to look
in the CR1000
Status
table to see the assigned IP address. This is shown under
the field name
IPInfo
.
295
Summary of Contents for CR1000
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 60: ...Section 4 System Quickstart Figure 16 PC200W View Line Graph 60 ...
Page 96: ......
Page 98: ...98 ...
Page 302: ......
Page 453: ...Section 8 Operation Figure 115 Using the Keyboard Display 453 ...
Page 456: ...Section 8 Operation Figure 118 Real Time Custom 456 ...
Page 457: ...Section 8 Operation 8 8 1 3 Final Memory Tables Figure 119 Final Memory Tables 457 ...
Page 458: ...Section 8 Operation 8 8 2 Run Stop Program Figure 120 Run Stop Program 458 ...
Page 460: ...Section 8 Operation Figure 122 File Edit 460 ...
Page 461: ...Section 8 Operation 8 8 4 PCCard Memory Card Display Figure 123 PCCard CF Card Display 461 ...
Page 478: ......
Page 506: ......
Page 536: ......
Page 636: ......
Page 642: ......
Page 644: ......
Page 676: ......
Page 677: ......