Appendix B. Status, Settings, and Data Table Information (Status/Settings/DTI)
PakBusTCPEnabled
Settings Editor: ???
Keyboard:
Settings (TCP/IP)
≈ line 39
Aliased from:
ServicesEnabled()
CRBasic:
variable = settings.keyword
;
SetSettings()
Enables (
True
) or disables (
False
) the PakBus TCP
service.
read/write
BOOLEAN
True
True
or
False
PakBusTCPPassword
Settings Editor:
PakBus/TCP Password
Keyboard:
Settings (General)
≈ line 10
CRBasic:
variable = settings.keyword
;
SetSettings()
When active (not blank), a log-in process using an
MD5 digest of a random number and this password
must take place successfully before PakBus
communications can proceed over an IP socket.
read/write
STRING
none
(inactive)
0 to 63
characters
PanelTemp
Station Status:
Panel Temperature
Keyboard:
Status Table
≈ line 15
CRBasic:
variable = status.keyword
Current wiring-panel temperature. Measurement is
made in background calibration.
read only
FLOAT
°C
n/a
-40 to 85
PingEnabled
Settings Editor:
Ping Enabled
Keyboard:
Settings (TCP/IP)
≈ line 38
CRBasic:
variable = settings.keyword
;
SetSettings()
Enables (
True
) or disables (
False
) the ICMP ping
service. Replaces old
ServicesEnabled()
.
read/write
BOOLEAN
True
True
or
False
PortConfig()
Keyboard:
Status Table
≈ line 51
CRBasic:
variable = status.keyword
Configuration of
C
terminals. Array elements in
numeric order of
C
terminals.
read only
STRING
array
Input
Input
,
Output
,
SDM
,
SDI-
12
,
Tx
,
Rx
PortStatus()
Keyboard:
Status Table
≈ line 50
CRBasic:
variable = status.keyword
States of
C
terminals configured for control.
On/high (
True
) or off/low (
False
). Array elements
in numeric order of
C
terminals. Updated every 500
ms.
read/write
BOOLEAN
array
False
True
or
False
pppDial
Settings Editor:
PPP Dial
Keyboard:
Settings (TCP/IP)
≈ line 28
CRBasic:
variable = settings.keyword
;
SetSettings()
Specifies the dial string that follows ATD (e.g., #777
for Redwing CDMA) or a list of AT commands
separated by ';' (e.g., ATV1;
AT+CGATT=0;ATD*99***1#), that are used to
initialize and dial through a modem before a PPP
connection is attempted. A blank string means that
dialing is not necessary before a PPP connection is
established. CRBasic program will recompile if
changed from NULL to not NULL, or from not
NULL to NULL.
read/write
STRING
none
n/a
624
Summary of Contents for CR1000
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 40: ......
Page 60: ...Section 4 System Quickstart Figure 16 PC200W View Line Graph 60 ...
Page 96: ......
Page 98: ...98 ...
Page 302: ......
Page 453: ...Section 8 Operation Figure 115 Using the Keyboard Display 453 ...
Page 456: ...Section 8 Operation Figure 118 Real Time Custom 456 ...
Page 457: ...Section 8 Operation 8 8 1 3 Final Memory Tables Figure 119 Final Memory Tables 457 ...
Page 458: ...Section 8 Operation 8 8 2 Run Stop Program Figure 120 Run Stop Program 458 ...
Page 460: ...Section 8 Operation Figure 122 File Edit 460 ...
Page 461: ...Section 8 Operation 8 8 4 PCCard Memory Card Display Figure 123 PCCard CF Card Display 461 ...
Page 478: ......
Page 506: ......
Page 536: ......
Page 636: ......
Page 642: ......
Page 644: ......
Page 676: ......
Page 677: ......